Fabman Bridge FB-V2 Скачать руководство пользователя страница 3

 

 

Never  position  the  product  in  direct  vicinity  of  a  bathtub,  shower,  bathroom,  swimming 
pool, or similar. Lethal hazard due to electric shock.

 

 

The product must not be exposed to extremes of temperature, direct sunlight or strong 
vibrations.  Keep  the  product  away  from  strong  magnetic  fields  generated  by  machines, 
electric motors or loudspeakers.

 

 

Do not operate the device in environments where there are high levels of dust, flammable 
gases, vapors or solvents. There is a danger of fire and explosion.

 

 

The product may get warm when it is powered. Therefore it must be surrounded by air - do 
not cover it with any material.

 

 

Do not use this product in hospitals or medical institutions. Radio waves may interfere with 
medical equipment. The same may also apply to other areas. 

 

 

Use the product only in a temperate climate, never in a tropical climate.  

 

 

The mains plug shall remain readily operable.  

2.3. Handling and use  

 

Never plug in, unplug or operate the product when your hands are damp or wet. There is a 
risk of a life-threatening electric shock.

 

 

Never connect the product to the power supply immediately after it has been transferred 
from  a  cold  room  into  a  warm  one  (e.g.  during  transport).  The  condensation  that  forms 
might destroy the device. Moreover, there is danger of electric shock. Allow the product to 
reach  room  temperature.  Wait  until  the  condensation  has  evaporated.  This  might  take 
several hours. Only then the product may be plugged into the mains socket and put into 
use.

 

 

Always  use  the  gripping  surface  to  pull  a  mains  plug  out  of  the  product.  Never  unplug  a 
mains plug from a mains socket by pulling the cable. 

 

 

Never  overload  the  product.  Note  the  maximum  permissible  connected  load  in  the 
chapter ‘Technical Data’. 

 

 

Disconnect the product from the mains socket in thunderstorms for reasons of safety. 

 

 

Do not use the product if it is damaged. There is a risk of a life-threatening electric shock in 
this  case,  dispose  of  the  product  in  an  environmentally  correct  manner.  Safe  operation 
can no longer be assumed if: 

 

 

the product shows visible signs of damage 

 

the  product  does  not  work  at  all  or  works  poorly  (leaking  smoke  or  a  smell  of 
burning,  audible  cracking  noises,  discoloration  to  the  product  or  the  adjacent 
surfaces) 

 

the product was stored under unfavorable conditions 

 

it was exposed to heavy loads during transport  

 

Never pour any liquids above or next to the product. You run the risk of causing a fire or a 
fatal electric shock. If any liquid has still managed to enter the device, immediately switch 
off the power supply to the mains socket at which the product is connected (turn off the 
fuse / circuit breaker / residual current operated circuit breaker of the associated circuit). 
Only then can you unplug the product from the mains socket and contact a specialist. Do 
not use the product any longer.

 

 

Always pull the product out of the mains socket (e.g. wall socket) before cleaning it or when 
the device will not be in use for a long time (e.g. for storage). 

 

Содержание Bridge FB-V2

Страница 1: ...Fabman Bridge FB V2 User Manual ...

Страница 2: ...this manual could lead to damage to this product and involves the risk of short circuits fire electric shock etc 2 Safety Instructions The warranty will be void in the event of damage caused by failure to observe these safety instructions We shall not accept liability for damage to property or personal injury caused by incorrect handling or non compliance with the safety instructions 2 1 General T...

Страница 3: ...ake several hours Only then the product may be plugged into the mains socket and put into use Always use the gripping surface to pull a mains plug out of the product Never unplug a mains plug from a mains socket by pulling the cable Never overload the product Note the maximum permissible connected load in the chapter Technical Data Disconnect the product from the mains socket in thunderstorms for ...

Страница 4: ...to the Fabman Bridge 3 2 Sign Up for a Fabman Account If you haven t done it yet sign up for a free Fabman Account on our website www fabman io Click the Try it for FREE Button and follow the instructions on the screen 3 3 Connect to your Fabman Bridge First plug in the Fabman bridge and it will power up automatically and show the setup screen Use a smartphone a tablet or a laptop computer to conn...

Страница 5: ...is automatically 3 5 Pairing the Fabman Bridge Once the setup is complete the bridge will begin pairing and will display a pairing code You can then use this code and assign the Fabman bridge to your equipment such as a laser cutter or a 3D printer in just a few steps Sign in to your Fabman account https fabman io login Click on the Configure Equipment menu item Is the equipment you d like to conn...

Страница 6: ...ymbol on the enclosure If the configuration is correct the bridge will switch on and show your name on the display You can switch if off again by pressing the left button Admins and account owners are automatically authorized to use any equipment To grant permission to non admin members you need assign them one or more packages Some standard packages have been created automatically for you If you ...

Страница 7: ...7 3 More detailed setup instructions can be found at www fabman io setup ...

Страница 8: ...s 802 11 b g n Operating frequency 2 4GHz from 2400MHz to 2483 5MHz Security WPA WPA2 Encryption WEP TKIP AES IP configuration DHCP NFC Operating frequency 13 56 MHz Operating distance up to 30 mm Supported tag types MIFARE NFCIP 1 2 ISO14443 A B ISO IEC 14443 A B FeliCa PCD mode ISO IEC 15693 ICODE VCD mode depends on tag type some types are not yet fully supported by the firmware RFID 125 kHz EM...

Страница 9: ...esidential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can b...

Отзывы: