FabiaTech Low Power Series Скачать руководство пользователя страница 10

FabiaTech Corporation 

 

Specifications 

‰

 

Vortex86DX3 (1GHz/L1:64K,L2:512K cache) Low Power CPU.  

‰

 

Onboard 512MB DDR3 RAM. (1GB maximum) 

‰

 

One Realtek 8111H 10M/100/1000 Base-TX Ethernet port or On board 
10M/100M Ethernet port (FB2402A Only). 

‰

 

Build-in VGA Controller support VGA port. 

‰

 

Three RS-232 ports and one RS232/RS422/RS485 port.

 

 

‰

 

Four USB (V2.0) ports and one SATA interface

.

 

‰

 

Compact Flash socket for Compact Flash module and Micro Drives. 

‰

 

PS/2 compatible keyboard and mouse interface. 

‰

 

Providing header for external speaker and hard disk access LED. 

‰

 

Watchdog timer and easy software programmable watchdog timer. 

‰

 

Flash BIOS with easy upgrade utility. 

‰

 

Compact size, 185 mm x 122 mm.  

‰

 

Power requirement: +5V only, 4.8A maximum. (2.03A Typical) 

 

 

 

 

 

 

 

 

 

Содержание Low Power Series

Страница 1: ...i FabiaTech Corporation IPC Solution Website http www fabiatech com Email support fabiatech com ISA CPU Card Low Power Series FB2402 User s Manual MAR 2021 Version 1 1 Part Number FB2402...

Страница 2: ...nishing performance or use of this document Trademarks Trademarks brand names and products names mentioned in this publication are used for identification purpose only and are the properties of their...

Страница 3: ...rs and Jumpers 10 CN5 Serial ATA hard Disk Connector 12 CN14 CPU or System Fan Connector Optional 12 CN7 m SATA Module Optional 12 CF1 JP5 Compact Flash Socket and Master Slave Select 13 J4 Power LAN...

Страница 4: ...ver and Utility 51 VGA Drivers 51 WINDOWS Driver 51 LAN Driver 52 BIOS Flash Utility 52 Watchdog Timer 53 Watchdog Timer Setting 53 Setup Watchdog Timer Step WDT0 and WDT1 55 Chapter 6 Technical Refer...

Страница 5: ...v Dimension 71...

Страница 6: ...vi...

Страница 7: ...unit supports 10 100 1000 interface network port on board 512MB DDR3 RAM four USB2 0 ports and a VGA controller Each FB2402 has four ports for I O communications Three RS232 and one RS 232 RS 422 RS48...

Страница 8: ...512GB 1GB Max Display VGA Multi I O Port Three RS232 One RS232 RS422 RS485 USB 2 0 Port Four SATA Port Storage Compact FAST Socket RJ45 LAN port 100 1000Mbps Realtek RTL8111H RD6040MP Watchdog Timer Y...

Страница 9: ...FabiaTech Corporation 3 Layout J4 DB1 CN9 DB2 CN12 CN13 JP7 JP8 BT1 CN7 CN11 BUS1 U19 SD1 CN4 J2 CN3 CN2 CN1 J1 J3 CN5 JP1 JP4 JP3 JP2 JP5 JP6 CN6 CN8 CN10 CN14 CF1...

Страница 10: ...rt VGA port Three RS 232 ports and one RS232 RS422 RS485 port Four USB V2 0 ports and one SATA interface Compact Flash socket for Compact Flash module and Micro Drives PS 2 compatible keyboard and mou...

Страница 11: ...ation of the cable s is compatible with the FB2402 system Note After FB2402 is installed it is recommended that you keep the diskette or CD that contains drivers and document files and keep the docume...

Страница 12: ...FabiaTech Corporation 6...

Страница 13: ...e board from its anti static bag wear an anti static strap to prevent the generation of Electricity Static Discharge ESD The ESD may be generated by man s physical touch It may do damage to the board...

Страница 14: ...r JST 6 pin CN12 Keyboard and Mouse connector Mini Din 6 pin CN13 Keyboard and Mouse connector JST 6 pin 2 0mm Optional CN14 Case CPU cooling fan connector Molex 3 pin 2 54mm Optional J1 JTAG Header R...

Страница 15: ...connector and any PS 2 type keyboard can plug into CN12 directly without extra adapter cable Use the keyboard mouse adapter cable optional you can connect keyboard and mouse simultaneously CN13 is ano...

Страница 16: ...Ports 1 2 3 4 Connectors and Jumpers The DB2 connector on bracket is 9 pin D type male connector The serial port 2 3 4 adapter cables are used to transfer 10 pin IDC connector into standard DB9 conne...

Страница 17: ...J4 DB1 CN9 DB2 CN12 CN13 JP7 JP8 BT1 CN7 CN11 BUS1 U19 SD1 CN4 J2 CN3 CN2 CN1 J1 J3 CN5 JP1 JP4 JP3 JP2 JP5 JP6 CN6 CN8 CN10 CN14 DB2 CN4 CN3 CN2 RS 232 RS 422 RS 485 1 1 DCD TX 485 6 2 DSR 2 3 RXD T...

Страница 18: ...14 CPU or System Fan Connector Optional J4 DB1 CN9 DB2 CN12 CN13 JP7 JP8 BT1 CN7 CN11 BUS1 U19 SD1 CN4 J2 CN3 CN2 CN1 J1 J3 CN5 JP1 JP4 JP3 JP2 JP5 JP6 CN6 CN8 CN10 CN14 CN7 m SATA Module Optional J4...

Страница 19: ...IDE J4 DB1 CN9 DB2 CN12 CN13 JP7 JP8 BT1 CN7 CN11 BUS1 U19 SD1 CN4 J2 CN3 CN2 CN1 J1 J3 CN5 JP1 JP4 JP3 JP2 JP5 JP6 CN6 CN8 CN10 CN14 CF1 Note The Compact Flash socket supports Compact Flash module a...

Страница 20: ...JP4 JP3 JP2 JP5 JP6 CN6 CN8 CN10 CN14 CN11 AUX Power Connector CN11 is the power connector for FB2402 is used with stand alone applications J4 DB1 CN9 DB2 CN12 CN13 JP7 JP8 BT1 CN7 CN11 BUS1 U19 SD1 C...

Страница 21: ...J3 CN5 JP1 JP4 JP3 JP2 JP5 JP6 CN6 CN8 CN10 CN14 CN6 DB 25 Signal CN6 DB 25 Signal 1 1 STROBE 2 14 AUTO FORM FEED 3 2 DATA 0 4 15 ERROR 5 3 DATA 1 6 16 INITIALIZE 7 4 DATA 2 8 17 PRINTER SELECT IN 9 5...

Страница 22: ...25 SA6 B9 12V B25 IRQ3 A10 IORDY A26 SA5 B10 KEY B26 DACK2 A11 AEN A27 SA4 B11 SMEMW B27 TC A12 SA19 A28 SA3 B12 SMEMR B28 ALE A13 SA18 A29 SA2 B13 IOW B29 5V A14 SA17 A30 SA1 B14 IOR B30 OSC A15 SA16...

Страница 23: ...SPLAY Using the BIOS setting for different types of LVDS LCD module then set your system properly and configures BIOS setting for the right type of LVDS LCD module you are using The following shows th...

Страница 24: ...create a compact video solution for the industrial environment J4 DB1 CN9 DB2 CN12 CN13 JP7 JP8 BT1 CN7 CN11 BUS1 U19 SD1 CN4 J2 CN3 CN2 CN1 J1 J3 CN5 JP1 JP4 JP3 JP2 JP5 JP6 CN6 CN8 CN10 CN14 DB1 Sig...

Страница 25: ...CN10 CN14 Pin Signal 1 12V 2 Ground 3 ENVDD 4 N C 5 VCC Pin Signal Pin Signal 1 Ground 2 LVDS_FP0 3 LVDS_FP0 4 Ground 5 LVDS_FP1 6 LVDS_FP1 7 Ground 8 LVDS_FP2 9 LVDS_FP2 10 Ground 11 LVDS_CK 12 LVDS...

Страница 26: ...FabiaTech Corporation 20...

Страница 27: ...ed firmware that interacts directly with the hardware components and facilitates interaction between the system hardware and the operating system The BIOS default values ensure that the system will fu...

Страница 28: ...on 3 PCIPnP 4 Boot Boot Settings Configuration Boot Device Priority Hard Disk Drives CD DVD Drivers 5 Security Change Supervisor Password Change User Password Boot Sector Virus Protection 6 Exit Save...

Страница 29: ...lt to configure the system in fail safe mode with predefined values Keyboard Convention On the BIOS the following keys can be used to operate and manage the menu Item Function ESC To exit the current...

Страница 30: ...is determined by POST Power On Self Test of the BIOS System Date Time Setup Highlight the Date field and then press the Page Up Page Down or keys to set the current date Follow the month day and year...

Страница 31: ...the items in the left frame of the screen such as IDE Configuration to go to the sub menu for that item You can display an Advanced BIOS Setup option by highlighting it using the Arrow keys All Advanc...

Страница 32: ...of the board s chipset features Pressing function key ALT F4 when in the Security menu reveals RDC Engineering Mode which must be enabled before the Chipset submenu on the Advanced menu tab becomes v...

Страница 33: ...You can use this screen to select options for the CPU information Use the up and down Arrow keys to select an item Use the Plus and Minus keys to change the value of the selected option Note The CPU C...

Страница 34: ...ctions of display for different TFT LCD display type LCD Panel Index When use the LCD the field specifies which select display resolution for different TFT LCD display type Available Options VBIOS 1 2...

Страница 35: ...9 Southbridge Configuration You can use this screen to select options for the South Bridge Configuration South Bridge is a chipset on the motherboard that controls the ISA functions and Watch Dog func...

Страница 36: ...utput request This delay takes place to wait for the I O to complete the request This field specifies the recovery time for 8bit or 16bit I O Available Options 1 clock 8 clock Default setting 1 clock...

Страница 37: ...Select IRQ NMI or Reset signal trigger of onboard watchdog Available Options IRQ 3 IRQ12 IRQ14 IRQ15 NMI and Reset Default setting Reset Watchdog 1 Timer This field is the Select when IRQ NMI or Reset...

Страница 38: ...can support up to two separate hard drives These drives have a master slave relationship which is determined by the cabling configuration used to attach them to the controller LBA Large Mode LBA Logi...

Страница 39: ...to activate the S M A R T System Management and Reporting Technologies function for S M A R T HDD drives This function requires an application that can give S M A R T message 32 Bit Data Transfer Thi...

Страница 40: ...Not Program PIO Mode If the bios cannot detect the CF or IDE this will allow you to indicate the CF or IDE card to Primary Channel or Secondary Channel Available Options Enabled and Disabled Default...

Страница 41: ...s These fields select the I O port address for each Serial port Available Options Disabled 3F8H 2F8H 3E8H 2E8H 360 260 368 268 3E0 and 2E0H Serial Port IRQ 1 This field is the Serial port 1 Interrupt...

Страница 42: ...2E8H 360 260 368 268 3E0 and 2E0H Serial Port Type This field item can select RS232 RS422 and RS485 of select Serial port 2 Available Options RS 232 RS 422 and RS485 Default setting RS 232 Serial Port...

Страница 43: ...t Legacy USB Support refers to the USB mouse and USB keyboard support Normally if this option is not enabled any attached USB mouse or USB keyboard will not become available until a USB compatible ope...

Страница 44: ...ions Enabled and Disabled Default setting Enabled USB Beep Message This field can select Enable the beep during USB device enumeration Available Options Enabled and Disabled Default setting Enabled US...

Страница 45: ...rt Select Enabled to activate the chipset Power Management and APM Advanced Power Management features Available Options Disable and Enable Default setting Disable ACPI Configuration ACPI Aware OS Enab...

Страница 46: ...ing it using the Arrow keys All Plug and Play BIOS Setup options are described in this section The Plug and Play BIOS Setup screen is shown below Clear NVRAM Clear NVRAM during system boot Available O...

Страница 47: ...upt as one of the following types based on the type of device using the interrupt Available Specified IRQ is available to the used by PCI PnP devices Reserved Specified IRQ is reserved for used by Leg...

Страница 48: ...rame of the screen such as Boot Device Priority to go to the sub menu for that item You can display a Boot BIOS Setup option by highlighting it using the Arrow keys All Boot Setup options are describe...

Страница 49: ...configure its drive 2 BIOS will not wait for 0 5 seconds after sending a RESET signal to the IDE drive 3 You cannot run BIOS Setup at system boot since there is no delay for the Hit Del To run Setup...

Страница 50: ...PS 2 Mouse Support The PS 2 mouse function is optional Before you configure this field make sure your system board supports this feature The setting of Enabled allows the system to detect a PS 2 mous...

Страница 51: ...ld is share memory architecture SMA for frame buffer memory SMA allows system memory to be efficiently share by the host CPU and allocated depending on user preference application requirements and tot...

Страница 52: ...Boot Device Priority on the Boot Setup screen and press Enter First Second Third Hard Disk Boot Device Set the boot device options to determine the sequence in which the computer checks which device...

Страница 53: ...ice drives in the system To access this screen select USB Device drives on the Boot Setup screen and press Enter Boot Network Drivers Use this screen to view the Network drives in the system To access...

Страница 54: ...word Change User Password Boot Sector Virus Protection To set the password please complete the following steps 1 Select Change Supervisor Password 2 Type the desired password up to 6 character length...

Страница 55: ...d the computer is turned on If Setup is chosen the password prompt appears if the BIOS executed Available options Setup Always Default setting Setup Boot Sector Virus Protection This option is near th...

Страница 56: ...essing function key ALT F4 when in the Security menu reveals RDC Engineering Mode which must be enabled before the Chipset submenu on the Advanced menu tab becomes visible and accessible Available Opt...

Страница 57: ...OM to a CF 2 Execute M2015_R5 msi file 3 The screen shows the SETUP type Press any key to enter the main menu 4 As the setup is completed the system will generate the message as follows Yes I want to...

Страница 58: ...the LAN DMPDX3 directory The installation method needs to go to Control Panel Hardware Device Manager Network Update Driver Select NETRDC inf Finish BIOS Flash Utility In the UTILITY directory there i...

Страница 59: ...an be programmed to be 30 5 seconds to 512 seconds Watchdog Timer Setting The watchdog timer WDT0 and WDT1 is a circuit that may be used from your program software to detect crashes or hang ups The wa...

Страница 60: ...chdog timer time out report signal select 0000 Reserved 0001 IRQ3 selected 0010 IRQ4 selected 0011 IRQ5 selected 0100 IRQ6 selected 0101 IRQ7 selected 0110 IRQ9 selected 0111 IRQ10 selected 1000 IRQ11...

Страница 61: ...it 1 to reset watchdog timer Only for WDT 0 Bit 5 0 Other function Please do not modify these bits Reload Register WDT1 WDT 1 AEh Bit 7 0 Writer this port to reload Watchdog Timer Counter The read dat...

Страница 62: ...h demonstrates how to enable the watchdog timer and set the time out period at 4 seconds Unlock Configuration Register Mov dx 22h Enter to extended function mode Mov al 13h Out dx al Mov dx 23h Mov al...

Страница 63: ...og before the new time out period in next trigger Timer Counter Mov al 02h Mov dx 3bh Index 3bh set 02h 4 sec Out dx al System Reset or Interrupt Mov al 38h Mov dx 22h Out dx al Mov al 50h Trigger IRQ...

Страница 64: ...e watchdog timer 1 and set the time out period at 4 seconds Enabled Watch dog Mov al 40h Mov dx a8h IO port A8h Bit 6 set 1 Out dx al Watchdog Timer Trigger Timer Counter Mov al 02h Mov dx aah IO port...

Страница 65: ...ts and connectors are in proper position and firmly attached If the errors still exist please contact with your distributor for maintenance POST BEEP Currently there are two kinds of beep codes in BIO...

Страница 66: ...installed correctly 2 All cables are correctly and firmly attached 3 The correct hard drive type is selected in BIOS Setup ERROR INITIALIZING HARD DISK CONTROLLER When this error occurs ensure the fo...

Страница 67: ...ritten to memory Use the location along with your system s memory map to locate the bad chip OFFENDING ADDRESS MISSING This message is used in connection with the I O CHANNEL CHECK and RAM PARITY ERRO...

Страница 68: ...114 bytes of general purpose RAM Because of the use of CMOS technology it consumes very little power and can be maintained for long periods of time using an internal Lithium battery The contents of ea...

Страница 69: ...ow base memory byte 16 High base memory byte 17 Low expansion memory byte 18 High expansion memory byte 19 2D Reserved 2E 2F 2 byte CMOS checksum 30 Low actual expansion memory byte 31 High actual exp...

Страница 70: ...abled 1 Enabled 15h Base Memory in 1KB increments Low Byte 16h Base Memory in 1KB increments High Byte 17h IBM compatible memory in 1KB increments Low Byte 18h IBM compatible memory in 1KB increments...

Страница 71: ...DMA Controller 1 020h 021h Interrupt Controller 1 022h 023h WDT 0 Control Register 040h 05Fh Timer Controller 060h 064h Keyboard Controller 070h 073h Real Time Clock NMI 080h 09Fh DMA Page Register 0...

Страница 72: ...r the service required The following table shows the IRQ used by the devices on the Industrial CPU Card Level Function IRQ0 System Timer Output IRQ1 Keyboard IRQ2 Interrupt Cascade IRQ3 Serial Port 2...

Страница 73: ...the ACE a completed MODEM control capability and a processor interrupt system that may be software tailored to the computing time required to handle the communications link The following table is a s...

Страница 74: ...rrupt Identification Register IIR Bit 0 0 if Interrupt Pending Bit 1 Interrupt ID Bit 0 Bit 2 Interrupt ID Bit 1 Bit 3 Must be 0 Bit 4 Must be 0 Bit 5 Must be 0 Bit 6 Must be 0 Bit 7 Must be 0 Line Co...

Страница 75: ...6 Must be 0 Bit 7 Must be 0 Line Status Register LSR Bit 0 Data Ready DR Bit 1 Overrun Error OR Bit 2 Parity Error PE Bit 3 Framing Error FE Bit 4 Break Interrupt BI Bit 5 Transmitter Holding Register...

Страница 76: ...visor Latch LS MS LS MS Bit 0 Bit 0 Bit 8 Bit 1 Bit 1 Bit 9 Bit 2 Bit 2 Bit 10 Bit 3 Bit 3 Bit 11 Bit 4 Bit 4 Bit 12 Bit 5 Bit 5 Bit 13 Bit 6 Bit 6 Bit 14 Bit 7 Bit 7 Bit 15 Desired Baud Rate Divisor...

Страница 77: ...FabiaTech Corporation 71 Appendix Dimension Top Side 74 2 81 3 25 4 43 3 11 2 85 7 17 8 184 9 36 1 3 2 121 9 36 3 24 3 23 7 24 6 73 7 4 3 23 1 4 8...

Отзывы: