![FabiaTech Low Power FB2503 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/fabiatech/low-power-fb2503/low-power-fb2503_user-manual_3125681076.webp)
FabiaTech Corporation
70
Serial Ports
The ACEs (Asynchronous Communication Elements ACE1 to ACE2) are used to convert
parallel data to a serial format on the transmit side and convert serial data to parallel
on the receiver side. The serial format, in order of transmission and reception, is a start
bit, followed by five to eight data bits, a parity bit (if programmed) and one, one and
half (five-bit format only) or two stop bits. The ACEs are capable of handling divisors of
1 to 65535, and produce a 16x clock for driving the internal transmitter logic.
Provisions are also included to use this 16x clock to drive the receiver logic. Also
included in the ACE a completed MODEM control capability, and a processor
interrupt system that may be software tailored to the computing time required to
handle the communications link.
The following table is a summary of each ACE accessible register
DLAB
Port Address
Register
Receiver buffer (read)
0
Base + 0
Transmitter holding register (write)
0
Base + 1
Interrupt enable
X
Base + 2
Interrupt identification (read only)
X
Base + 3
Line control
X
Base + 4
MODEM control
X
Base + 5
Line status
X
Base + 6
MODEM status
X
Base + 7
Scratched register
1
Base + 0
Divisor latch (least significant byte)
1
Base + 1
Divisor latch (most significant byte)
Receiver Buffer Register (RBR)
Bit 0-7: Received data byte (Read Only)
Transmitter Holding Register (THR)
Bit 0-7: Transmitter holding data byte (Write Only)
Interrupt Enable Register (IER)
Bit 0: Enable Received Data Available Interrupt (ERBFI)
Bit 1: Enable Transmitter Holding Empty Interrupt (ETBEI)
Содержание Low Power FB2503
Страница 6: ......
Страница 26: ...FabiaTech Corporation 20...
Страница 30: ...FabiaTech Corporation 24...
Страница 44: ...FabiaTech Corporation 38 Default setting Disable...
Страница 56: ...FabiaTech Corporation 50...