FabiaTech Corporation
53
Send out one character (Transmit)
Step 1: Enabled TXC signal, and the bit 0 of the address of 4 just sets “1”.
Step 2: Send out the data. (Write this character to the 0 of the current
COM port address)
Step 3: Wait for the buffer’s data empty. Check transmitter holding register
(THRE, bit 5 of the address of 5), and transmitter shift register
(TSRE, bit 6 of the address of 5) are all sets must be “0”.
Step 4: Disabled TXC signal, and the bit 0 of the address of 4 sets “0”
Send out one block data (Transmit – the data more than two characters)
Step 1: Enabled TXC signal, and the bit 0 of the address of 4 just sets “1”.
Step 2: Send out the data. (Write all data to the 0 of the current COM
port address)
Step 3: Wait for the buffer’s data empty. Check transmitter holding register
(THRE, bit 5 of the address of 5), and transmitter shift register
(TSRE, bit 6 of the address of 5) are all sets must be “0”.
Step 4: Disabled TXC signal, and the bit 0 of the address of 4 sets “0”
Receive data
The RS-485’s operation of receiving data is in the same of the RS-232’s.
Basic Language Example
a. Initial 86C450 UART
10
OPEN “COM1:9600,m,8,1”AS #1 LEN=1
20
REM Reset DTR
30
OUT &H3FC, (INP(%H3FC) AND &HFA)