Faber Relaxed L Smart Скачать руководство пользователя страница 7

 

Installation manual Relaxed M,L Smart

 

 

6 < 

<

 

<

 

1

 

Dear user 

Congratulations on your purchase of a Faber fire! A 
quality product from which you will experience 
warmth and atmosphere for many years. We 
recommend that you read this manual carefully 
before using the fireplace. If any problem arises 
despite our strict quality control, you can always 
contact your dealer or Glen Dimplex Benelux B.V. 

 

For any warranty claims, it is essential you first 
register your fireplace. During this registration, 
you’ll find all information regarding our warranty. 
 

 

Please note! 
The details of your fireplace can be found in 
the user manual. 

 
You can register your fire at: www.faberfires.co
 
Glen Dimplex Benelux B.V. 
Address:  Saturnus 8 
 

 NL-8448 CC 
 Heerenveen 

Tel: 

 +31 (0)513 656 500  

Email:   [email protected] 
Info: 

 www.faberfires.com 

1.1

 

Introduction 

Installation and maintenance of the appliance must 
be carried out by a professional with proven 
knowledge and competence. A professional takes 
into account all technical aspects such as heat 
radiation and gas connection as well as flue gas 
exhaust requirements. 
 
Where the installation instructions are not clear, 
national/local regulations must be followed. 

1.2

 

Check 

Check the fireplace for transport damage and 
immediately report any damage to your supplier. 

1.3

 

CE Declaration 

We hereby declare that Glen Dimplex Benelux B.V. 
released Faber gas-atmosphere heating appliance 
by its design and construction method complies 
with the Regulation (EU): 2016/426 and (EU) 
2015/1188. 
 
Product: gas room heater 
Model:   Relaxed M Smart 
 

 Relaxed L Smart 

 
This declaration will become null and void as soon 
as the unit is in any way modified without written 
authorization of Glen Dimplex Benelux B.V. 

2

 

Safety instructions 

 

 

Please note! 

It is advisable to always install a screen for the 
fireplace if children, elderly or disabled people are 
present in the same room as the fireplace. If 
regularly vulnerable persons can be present in the 
room without supervision, sufficient protection 
must always be placed around the fireplace. 

 

This appliance must be installed according 
with the rules in force and used only in a 
sufficiently space. 

 

The appliance must be checked annually 
in accordance with this installation 
manual and the applicable national and 
local regulations. 

 

Ensure that the data on the type label 
matches the local gas type and pressure. 

 

The appliance is designed for atmosphere 
and heating purposes. This means that all 
visible surfaces, including the glass, can 
become hotter than 100°C. An exception 
by free standing models is the underside 
of the fireplace and the control buttons. 

 

Do not use the remote control and / or 
app outside the room where the fire is 
located. So that you are always aware of 
the situation around the fireplace when it 
is being operated. 

 

The settings and the construction of the 
fireplace must not be changed! 

 

Do not place extra imitation wood or 
other material on the burner or in the 
combustion chamber. 

 

Do not place any combustible materials 
within 0,5m of the radiation area of the 
fire. 

 

Through the natural air circulation of the 
fireplace moisture and uncured volatile 
components from paint, building 
materials and carpeted floors, etc. are 
attracted. These parts can settle as soot 
on cold surfaces. Therefore do not light 
the fireplace shortly after installation. 

2.1

 

Using the fire for the first time 

Provide extra ventilation and open all the windows 
of the room during the initial start-up of the fire. 
Let the fire burn at the highest setting for a few 
hours so that the paint gets the chance to harden 
and any released vapours are safely removed. Keep 
vulnerable people and pets out of this room during 
this process. 

 

Содержание Relaxed L Smart

Страница 1: ...Installation manual Relaxed M Smart Relaxed L Smart ENG 40010635 2010 ...

Страница 2: ...Installation manual Relaxed M L Smart 1 ...

Страница 3: ...Installation manual Relaxed M L Smart 2 ...

Страница 4: ...Installation manual Relaxed M L Smart 3 1 1 1 2 1 3 1 4 1 5 1 6 ...

Страница 5: ...Installation manual Relaxed M L Smart 4 1 7 2 0 2 1 2 2 2 3 2 4 2 5 A C B 1 2 ...

Страница 6: ...Installation manual Relaxed M L Smart 5 ...

Страница 7: ...se note It is advisable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently spa...

Страница 8: ...he flue material EN 1856 1 T600 N1 D Vm L20040 O 50 Outlets fig 1 5 The balanced flue pipe for combined air supply and discharge can use a wall terminal or a roof terminal Verify that the desired outlet meets the local regulations regarding pollution and ventilation openings Please note For proper functioning the outlet must at least be 0 5m away from Corners of the building Roof overhangs and bal...

Страница 9: ...d parts from the fireplace Prepare the gas connection on the gas valve 4 5 Positioning the fireplace Take into account the installation requirements see chapter 3 Place the fireplace at the right place and level it see fig 1 1 C or 1 2 C Rough height adjustment With the adjustable legs Accurate height adjustment With the adjustable feet 4 6 Installing the flue pipes Install the flue pipes accordin...

Страница 10: ...aterial on the burner at once It is possible that the burner gets clogged See the supplied decoration instruction card or chapter 18 1 or 18 2 Place part of the ash material at the burner and the cover plate Place the log set Divide the rest of the ash material at the burner and the cover plate Please note Keep the pilot flame free from ash material Start the fireplace as described in the user man...

Страница 11: ...nd instructions on care and cleaning of the glass Emphasize the danger of fingerprint burns at the glass Handover to customer o installation manual o user manual o decoration instruction card o suction cups o sample Faber glass polish 9 Annual maintenance Check Check and clean if necessary the combustion chamber the burner the pilot flame the wooden logs for breakage the glass es the outlet Replac...

Страница 12: ...ipes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the elements H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are elbows entirely in the horizontal plane fig 12 1 12 2 and 12 3 I K and Q Elbows 45 or 30 in the horizontal plane Horizontal elbows are ...

Страница 13: ...40 00 30 00 0 00 x x x x 12 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 13 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 14 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 15 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 16 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 17 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 18 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 19 6...

Страница 14: ... 60 00 50 00 50 00 40 00 30 00 x x x x 12 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 13 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 14 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 15 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 16 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 17 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 18 65 00 65 00 60 00 50 00 50 00 40 00 30 0...

Страница 15: ...Installation manual Relaxed M L Smart 14 12 Examples flue materials ...

Страница 16: ... 5 Flue length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizont...

Страница 17: ... installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In case...

Страница 18: ...class B B B Energy efficiency index EEI 85 85 85 Type heating output control room temperature no no no no yes no Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection no With electronic control of the room temperature With electronic control of the room temperature plus day tim...

Страница 19: ...Energy efficiency index EEI 84 84 84 Type heating output control room temperature no no no no yes no Diameter outlet inlet 100 150 Technical data Type indication s Relaxed Smart L Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 15 0 15 kW Other control options One...

Страница 20: ...sition outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short...

Страница 21: ...Installation manual Relaxed M L Smart 20 16 Troubleshooting guide ...

Страница 22: ...Installation manual Relaxed M L Smart 21 ...

Страница 23: ...Installation manual Relaxed M L Smart 22 17 Dimensional drawings 17 1 Relaxed M Smart ...

Страница 24: ...Installation manual Relaxed M L Smart 23 17 2 Relaxed L Smart ...

Страница 25: ...Installation manual Relaxed M L Smart 24 17 3 Remote access door A9299463 ...

Страница 26: ...Installation manual Relaxed M L Smart 25 17 4 Ventilation grid article number A9296400 ...

Страница 27: ...Installation manual Relaxed M L Smart 26 18 Decoration instruction card 18 1 Log set Relaxed M Smart ...

Страница 28: ...Installation manual Relaxed M L Smart 27 18 2 Log set Relaxed L Smart ...

Страница 29: ...Installation manual Relaxed M L Smart 28 ...

Страница 30: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Отзывы: