background image

Version 12/04 - Page 5

PREPARE  THE  WALL

1. 

Disconnect and move freestanding range from cabinet 

opening to provide easier access for installation.  Put a thick, 

protective covering over cooktop, set-in range or countertop 

to protect from damage or dirt.

2. 

Determine and clearly mark with a pencil the center line 

on the wall where the rangehood will be installed.

3. 

The  Pro  Magnum  attaches  to  the  wall  by  mounting 

screws indicated in 

FIGURE 5

.  For the 30" and 36" models, 

there are two mounting screws.  For the 48" model, there are 

four mounting screws.  Install the screws into the wall.  The 

screws should be inserted into the wall until the screw head 

is flush with the wall.  

WARNING:  THE SCREWS PROVIDED FOR MOUNTING 

THIS  RANGEHOOD  MUST  BE  INSERTED  INTO  SOLID 

WOOD.  THESE MUST NOT BE INSERTED INTO SHEET 

ROCK.

Determine the proper location for each bracket and install the 

brackets on the wall.  

MAKE SURE THAT THE SCREWS 

AND BRACKETS ARE SECURELY FASTENED TO THE 

WALL.

5. 

Determine and make all necessary cuts in the wall for 

the ductwork.  The Pro Magnum vents either through the top 

or the rear of the rangehood.  Each rangehood is shipped from 

the factory vented through the top.  In order to vent to the rear, 

the blower inside the rangehood must be turned to the rear.  

The dimensions for the duct openings are given in 

FIGURE 

8

.  The 48" model uses two  3 & 1/4" by 10" duct openings.  

Install all ductwork before installing the rangehood.  

6. 

Determine  the  proper  location  for the Power  Supply 

Cable  as  indicated  in 

FIGURE  8

.    Note  that  the  30"/36" 

versions have the option of top or rear electrical connection 

while the 48" version has only the rear option.  Use a 1 & 1/4" 

Drill Bit to make this hole.  Run the Power Supply Cable.  Use 

caulking to seal around the hole.  DO NOT turn on the power 

until installation is complete.

FIGURE 8

4. 

The 

Telescopic Chimney Kit

 and 

Full Width Duct 

Cover

 use different bracket systems to attach to the wall.  

FIGURE 6

 provides the position for the telescopic chimney 

brackets.  

48"  VERSION

30"  AND 36"  VERSIONS

FIGURE 7

FIGURE  5

FIGURE 6

FIGURE 7

 provides the dimensions for the 

Full Width Duct 

Cover

 brackets.  The 

Full Width Duct Cover

 also attaches to 

the top of the rangehood with screws provided.  The 

Full Width 

Duct Cover

 must be attached to the top of the rangehood 

before mounting the rangehood to the wall.

Electrical Opening

Electrical Opening

If a backsplash is to be used with this rangehood, it must be 

installed before the rangehood.  Installation instructions for 

the backsplash are supplied in its box.   The height  of  the 

backsplash will determine the bottom edge of the canopy.

Содержание Pro Magnum

Страница 1: ...Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POURMINI...

Страница 2: ...be moved if servicing is ever nec essary AULListed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When making the electrical con...

Страница 3: ...tion est n cessaire pour tous les appareils combustion Suivez les conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Assoc...

Страница 4: ...ersonal injury PERSONAL INJURY HAZARD 9 Feet Straight Duct 2 90 Elbows Wall Cap Total System 9 0 feet 10 0 feet 0 0 feet 19 0 feet FIGURE 2 3 0 feet 5 0 feet 12 0 feet 0 0 feet 45 Elbow 90 Elbow 90 Fl...

Страница 5: ...r the blower inside the rangehood must be turned to the rear The dimensions for the duct openings are given in FIGURE 8 The 48 model uses two 3 1 4 by 10 duct openings Install all ductwork before inst...

Страница 6: ...Install the damper before hanging the rangehood The damper attaches to the rangehood by two small screws provided in the hardware package If 48 hood is to be connected to 10 round duct install the Du...

Страница 7: ...ERVICE All Faber products are warranteed against any defect in materials or workmanshipfortheoriginalpurchaserforaperiodof1yearfromthe date of original purchase This warranty covers labor and replace...