![Faber Odense Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/faber/odense/odense_installation-manual_535932010.webp)
Installation manual Odense
9 <
<
<
<
Assess whether the flame distribution is
good. Move or remove any ash material
to create a nice glow bed.
Install the front glass and check the fire
image.
7
Checking the installation
Checking for gas leaks
Check with a gas leak finder all connections and
pipes for gas leakage.
Check primary- and burner pressure
Check if the primary pressure correspond to the
data on the rating plate.
Measuring the primary pressure:
Close the shutoff valve. Turn the
measuring nipple “A” (fig. 1.1) a few turns
to open and connect a measuring hose to
the gas valve.
Take this measurement when the
fireplace runs at high and low settings.
Do not use the device if the pressure
deviates (+20% or -20%).
Measuring the burner pressure:
Check the burner pressure only with proper
primary pressure.
Turn measuring nipple “B” (see fig. 1.1)
some turns open and connect a measuring
hose to the gas valve.
The pressure must correspond to the
value indicated in the technical
specifications of this manual. In case of
deviation contact the manufacturer.
Please note!
Close both pressure measuring nipples and
check for gas leakage.
Check ignition and burner
Ignite the fireplace by using the remote control as
described in the user manual and test all burner
possibilities.
7.1
Checking the flame image
Let the fireplace burn for at least 20 minutes at
highest setting and check the flame for:
flame distribution;
colour of the flames.
If one or both points are not acceptable then
check:
The position of the logs and/or the
amount of ash material;
The pipe connections for leaks.
(in case of blue flames);
That the correct flue restrictor is fitted
(see fig. 1.4-A);
The outlet:
o
Wall terminal has the correct
position and side up;
o
Roof terminal has the correct
position.
o
If the maximum lengths of the
flue gas outlet is not exceeded.
8
Instructions for client
Recommend that the fire should be
checked annually by a qualified specialist
to ensure the safe use and to guarantee a
long service life.
Provide instructions on the operation of:
o
the appliance;
o
the remote control;
o
if present, the App and its
settings.
Give advice and instructions on care and
cleaning of the glass:
Emphasize the danger of fingerprint burns
at the glass.
Handover to customer:
o
installation manual;
o
user manual;
o
decoration instruction card;
o
suction cups;
o
sample Faber glass polish.
9
Annual maintenance
Check
Check and clean if necessary:
the combustion chamber;
the burner
the pilot flame;
the wooden logs for breakage;
the glass(es);
the outlet.
Replace ash material if necessary.
Cleaning
Remove the front glass (see chapter 5).
You can clean the glass with Faber glass polish.
Содержание Odense
Страница 1: ...Installation manual Odense ENG 40010898 2010 ...
Страница 2: ...Installation manual Odense 1 ...
Страница 3: ...Installation manual Odense 2 ...
Страница 4: ...Installation manual Odense 3 1 1 1 2 1 3a 1 3b 1 4 A ...
Страница 5: ...Installation manual Odense 4 1 5 1 6 1 7 1 8 2 0 2 1 1 2 ...
Страница 6: ...Installation manual Odense 5 2 2 2 3 ...
Страница 14: ...Installation manual Odense 13 12 Examples flue materials ...
Страница 19: ...Installation manual Odense 18 16 Troubleshooting guide ...
Страница 20: ...Installation manual Odense 19 ...
Страница 21: ...Installation manual Odense 20 ...
Страница 22: ...Installation manual Odense 21 17 Dimensional drawings 17 1 Odense ...
Страница 23: ...Installation manual Odense 22 17 2 Gas connection ...
Страница 24: ...Installation manual Odense 23 18 Decoration instruction card ...
Страница 25: ...Installation manual Odense 24 ...
Страница 26: ...Installation manual Odense 25 ...
Страница 27: ...Installation manual Odense 26 ...
Страница 28: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...