The combined supply and discharge can be done both via wall or 
through the roof or through an existing chimney. Verify if the 
position of the terminal meets the local regulations regarding 
ventilation openings.

 

The flue outlet can end on an external wall or a roof. Check 
whether the outlet desired by you complies with local requirements 
concerning good function and ventilation systems.

 

 

Please note:

 

For a proper functioning the terminal should be at least 0,5m. away 
from:

 

 

Corners of the building

 

 

Roof overhangs and balconies

 

 

Eaves (with the exception of the roof ridge, see Chapter 15)

 

 

    3.4.1 

C11, wall terminal 

 

 

For a facade or wall outlet use a wall terminal (see fig. 1.9 C11). 
Depending on the calculation this can be a diameter of 
130/200mm or 100/150mm.

 

 

    3.4.2 

C31, roof terminal 

 

 

For a flat or pits roof outlet use a long roof outlet with a diameter of 
100/150mm (see fig. 1.9 C31).

 

 

    3.4.3 

C91, existing chimney 

 

 

For an existing chimney use the short chimney outlet with a 
diameter of 100/150mm (see fig. 1.9 C91).

 

In this case the existing chimney acts as air inlet an  inserted flexible 
stainless steel pipe discharges the flue gas. The top and  the bottom 
should be airtight.

 

Depending on the calculated outlet diameter, use a flexible 
stainless steel tube of Ø100mm or Ø130mm with CE marking 
for 600°C.

 

 

Please note:

 

The minimum chimney diameter for a 130mm flexible stainless 
steel pipe must 200x200mm. and for a 100mm flexible stainless 
steel pipe 150x150mm.

 

 

 

 

The gas connection must comply with the applicable local 
standards.

 

We advise using a Ø 15mm gas connection directly from the gas 
meter to the appliance, with a shut-off valve in the proximity of the 
appliance, which must always be freely accessible.

 

Position the gas connection so that it is easily accessible at all 
times for service, and that the burner unit can be disassembled.

 

 

 

The power supply must comply with the applicable local standards. 
A wall socket 230VAC/50Hz must be installed near the fire.

 

For power supply make use of the included plug adapter.

 

See fig 2.8 or 2.9 for the wiring diagram of this connection and the 
LED Symbio module.

 

A = plug adapter 
B = control unit 
C = receiver

 

D = LED Symbio module 
E = control block

 

F = magnet valve

 

 

    4.2.1       Smart-Home installation 

 

 

You can connect the control unit to the receiver with an external 
source, such as a Domotica home automation system, using the 
5-wire pin connector.

 

 

(Part G60-ZCE/1000, art.no.: 06022950). The total length of the 
cable may not exceed 8m. Signal relay (gold-plated contacts) or 
opto-couples are recommended!

 

 

    4.2.2       Faber ITC (Intelligent Technical Controller) 

 

 

The ITC gives you more options, such as ECO control, control, 
error messages, maintenance advice and such.

 

For further information see the ”ITC” user manual.

 

 

 

 

 

You can also connect to an existing fireplace chimney. The existing 
chimney functions then as air supply and a flexible stainless steel 
tube drawn through the chimney carries the flue gases. The flexible 
stainless steel tube of Ø100mm must have a CE mark have up to 
600°C.

 

The chimney must have the following conditions:

 

 

The channel of the chimney must be at least 150x150mm.

 

 

There should be no more than one device on a chimney.

 

 

The chimney must be in good condition:

 

-

 

no leakage

 

-

 

well cleaned

 

 

For more information about connections to existing chimneys, ask 
the installation manual “chimney connection set”.

 

 

Remove the fire from its packaging. Ensure that the gas 
supply pipes under the appliance are not damaged.

 

 

Remove frame and glass and take the packaged parts from 
the fire.

 

 

Store frame and glass in a safe place.

 

 

Prepare the gas connection on the regulator.

 

 

 

Take the installation requirements into account (see Chapter 3). 
Place the appliance in the right position and set the height with the 
(optional) leg levelers.

 

Height adjustment and levelling of the appliance (see point C, fig. 
1.1).

 

Rough height adjustment:

 

 

With the extendable (optional) leg. 

Fine adjustment:

 

 

With the adjustable feet.

 

3.4 

Terminals

 

3.5 

Existing chimney

 

4.3 

Preparing the fire

 

4.1 

Gas connection

 

4.2 

Electrical connection

 

4.4 

Positioning the fire

 

4 Preparation and installation 

instructions 

Содержание MatriX 1050/650-I

Страница 1: ...40011616 1623 MatriX 1050 650 ENG MatriX 1050 650 ...

Страница 2: ...Installation Instructions 1 2 1 3 2 1 0 1 1 ...

Страница 3: ...Installation Instructions 1 8 1 9 3 D E 1 4 1 5 1 6 1 7 ...

Страница 4: ...Installation Instructions 4 2 0 2 2 2 1 ...

Страница 5: ...Installation Instructions 2 4 5 2 3 ...

Страница 6: ...Installation Instructions 6 2 5 K 2 6 2 7 ...

Страница 7: ...Installation Instructions 2 9 7 I T C versie Symax versie 2 8 ...

Страница 8: ...Installation Instructions 8 3 0 3 1 3 2 3 3 ...

Страница 9: ...Installation Instructions 9 3 4 3 5 ...

Страница 10: ...Installation Instructions 10 4 0 4 1 4 2 4 3 ...

Страница 11: ...Installation Instructions 11 4 4 4 5 ...

Страница 12: ...Installation Instructions 12 WRONG OK 4 6 ...

Страница 13: ...nt building materials and carpeted floors etc are attracted These parts can settle as soot on cold surfaces Therefore do not light the fire shortly afterinstallation Light the fire for the first time and run for several hours on the highest setting so that the paint can cure Provide adequate ventilation so that any fumes can disperse we recommend vacating the room during this process Please note 1...

Страница 14: ...0Hz must be installed near the fire For power supply make use of the included plug adapter See fig 2 8 or 2 9 for the wiring diagram of this connection and the LED Symbio module A plug adapter B control unit C receiver D LED Symbio module E control block F magnet valve 4 2 1 Smart Home installation You can connect the control unit to the receiver with an external source such as a Domotica home aut...

Страница 15: ... support fig 2 6 L distance holder glass support fig 2 6 Please note Ensure that the fire is not load bearing with regard to the false chimney breast Build the false chimney breast against the moldings H and distance profiles I see fig 2 4 and 2 7 Keep a minimum distance of 2mm between the false chimney and the appliance because of the extension of the appliance Take into account the thickness of ...

Страница 16: ...ect the unit if the pressure is toohigh Measuring the burner pressure Check the burner pressure only with proper primary pressure Turn measuring nipple A see fig 1 7 some turns openand connect a measuring hose to the gas regulator The pressure must correspond to the value indicated in the technical specifications of this manual In case of deviation contact the manufacturer Please note Close all pr...

Страница 17: ...nd Mac Google Play Android smartphones and Android tablets Alternatively use the exhaust calculation table see chapter 13 The alternatives of outlet lengths and any restrictors are set out in the restrictor table In the table we work with start length STL total vertical height TVH and total horizontal length THL Start length STL This is the first part that is placed on the fire and represents a ce...

Страница 18: ...le at the right vertical TVH and horizontal length THL For x and if the values are outside the table then the combination is not allowed Only then adjust the TVH or THL If a value is indicated check that the calculated STL value is not lower than indicated in the table In this case STL must be adjusted The found value indicates the width of the restrictor 0 means no restrictor Standard is a restri...

Страница 19: ...x x x x x 11 60 2 30 2 0 2 x x x x x x x x 12 60 2 30 2 0 2 x x x x x x x x 13 70 2 30 2 0 2 x x x x x x x x 14 70 2 30 2 30 2 0 2 x x x x x x x 15 70 2 30 2 30 2 0 2 x x x x x x x 16 70 2 30 2 30 2 0 2 x x x x x x x 17 80 2 30 2 30 2 0 2 x x x x x x x 18 80 2 40 2 30 2 30 2 x x x x x x x 19 80 2 40 2 30 2 30 2 x x x x x x x 20 80 2 40 2 40 2 30 2 x x x x x x x 21 80 2 50 2 40 2 30 2 x x x x x x x...

Страница 20: ...50 4 50 4 45 4 45 4 x x x x 11 60 4 60 3 60 4 50 4 50 4 50 4 45 4 x x x x 12 60 4 60 3 60 4 60 4 50 4 50 4 50 4 x x x x 13 60 4 60 3 60 4 60 4 60 4 50 4 50 4 x x x x 14 70 4 70 3 60 4 60 4 60 4 60 4 50 4 x x x x 15 70 4 70 3 70 4 60 4 60 4 60 4 60 4 x x x x 16 70 4 70 3 70 4 70 4 60 4 60 4 60 4 x x x x 17 80 4 70 3 70 4 70 4 70 4 60 4 60 4 x x x x 18 80 4 80 3 70 4 70 4 70 4 70 4 60 4 x x x x 19 8...

Страница 21: ...0 4 60 4 60 4 60 4 60 4 60 4 x x x x 11 70 4 70 4 70 4 60 4 60 4 60 4 60 4 x x x x 12 70 4 70 4 70 4 70 4 60 4 60 4 60 4 x x x x 13 70 4 70 4 70 4 70 4 70 4 60 4 60 4 x x x x 14 70 4 70 4 70 4 70 4 70 4 70 4 60 4 x x x x 15 70 4 70 4 70 4 70 4 70 4 70 4 70 4 x x x x 16 80 4 70 4 70 4 70 4 70 4 70 4 70 4 x x x x 17 80 4 80 4 70 4 70 4 70 4 70 4 70 4 x x x x 18 80 4 80 4 80 4 70 4 70 4 70 4 70 4 x x...

Страница 22: ...Installation Instructions 22 12 Examples flue materials fig 12 1 fig 12 2 fig 12 3 ...

Страница 23: ...e length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizontal dir...

Страница 24: ...the top row of the table Is the found value X then the installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind thecomma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend incase o...

Страница 25: ...41 0 443 gr h 830 860 Burner pressure at full mark mbar 13 8 20 5 27 1 Injector main burner mm 4x 1 3 1x 1 6 5x 0 9 5x 0 9 Reduced input restraint mm 2 1 1 6 1 6 Pilot flame SIT145 SIT145 SIT145 Code pilot flame injector Nr 36 Nr 23 Nr 23 Diameter outlet inlet mm 130 200 130 200 130 200 Gas controle valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical connection V 230 230 230 Batteries remot...

Страница 26: ...nal Only for existing Chimney connection Extension pipe over roof Location Position outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each o...

Страница 27: ... valve 1 long beep Thermocouple circuit is interrupted check 8 wire cable from receiver to the gas valve If the wire on the bottom of the gas valve is not broken or stuck and makes a ground contact Motor gas valve doesn t work Micro switch on gas valve doesn t work Replace faulty parts Check HT lead and sparking plug Check the distance between sparking plug and pilot top Insulate the HT lead Cut o...

Страница 28: ... NO NO NO NO YES The flames areyellow after 10 15minutes Flame stays blue liftfrom NO the burner and fireswitch of Check fluecalculation horizontal length to long Correct fluerestrictor Flue parts not correctinstalled Wall roof terminalblocked Min 4 mV YES Min 1 2 mVolt ...

Страница 29: ...eiver Gas vlave broken poor or loose contact NO Short circuit in wiring Install a ground cable from the gas valve to the appliance Check complete wiring about thermocouple circuit Replace faulty parts YES the fire works OK RESET the receiver Check the wiring from solenoid valve to receiver Faulty solenoid valve Faulty receiver Replace solenoid valve Replace receiver ...

Страница 30: ...Installation Instructions 30 17 Dimensional drawings 17 1 MatriX 1050 650 I ...

Страница 31: ...Installation Instructions 31 17 2 MatriX1050 650 IIL ...

Страница 32: ...Installation Instructions 32 17 3 MatriX1050 650 IIR ...

Страница 33: ...Installation Instructions 33 17 4 MatriX1050 650 III ...

Страница 34: ...Installation Instructions 34 17 5 Wall bracket ...

Страница 35: ...Installation Instructions 35 17 6 Remote acces door ...

Страница 36: ...Installation Instructions 36 17 7 Ventilation grid ...

Страница 37: ...Installation Instructions 37 17 8 Adjustable feet ...

Страница 38: ...Installation Instructions 38 ...

Страница 39: ...Installation Instructions 39 ...

Страница 40: ...Installation Instructions 40 ...

Страница 41: ...Installation Instructions 41 Dealerinfo www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Отзывы: