User manual GV60TT/10
10 <
<
<
<
reset button on the receiver
(fig. 2.3.1),
for setting the transmitter code:
see section 4.2.
Please note!
If unintentional the start-process started when
the fire is in operation, the step-burner will
not operate for 45 sec.
If the remote control unit of the fire itself does not
function properly after these checks, we refer you
to your dealer or professional craftsman.
9
Manual ignition (Only by a professional
craftsman)
Please note!
This action is intended for service purposes
only.
For manual ignition take the following steps:
1.
Remove the ignition cable of the receiver
(fig. 1.1-G) and place this on the gas block.
(fig.1.2-D)
2.
Twist the knob B to the right
with the
arrow to the OFF position. (fig.1.3)
3.
Twist the dial A to the right
with the
arrow in the MAN position (fig.1.2). Now
the pilot light valve C and the piezo-
ignition E are accessible.
4.
Use a screwdriver to keep the pilot light
valve C pressed in, simultaneously press
the piezo-ignition E (fig.1.2 ) briefly a few
times, the pilot light will ignite now.
5.
If the pilot light is burning, wait for
approx. 20 seconds before releasing the
pilot light valve.
6.
Now twist the dial A to the left
with the
arrow to the ON position. (fig.1.2)
7.
Now the flame height can be adjusted by
twisting the knob B to the left
past the
ON position.(this causes a rattling sound!)
(fig.1.2)
8.
The step-burner can not be switched
manual
Содержание GV60TT/10
Страница 1: ...User manual GV60TT 10 ENG 40011903 2018...
Страница 2: ...User manual GV60TT 10 1...
Страница 4: ...User manual GV60TT 10 3 1 0 1 1 v 1 2 1 3 1 4 1 5 1 6 1 7 G...
Страница 5: ...User manual GV60TT 10 4 1 8 1 9 2 0 2 1 2 2 2 3 2 3 1 2 3 2 Reset DC 6V connection...
Страница 6: ...User manual GV60TT 10 5 2 4 2 5 2 6...
Страница 12: ......