Faber FWH OTTIMO 501CH Скачать руководство пользователя страница 11

10

This  electric  water  heater  should  be  installed  at  the  place  without  sunshine  or  rain  spray. 

Please cut off power supply if not use for long time.

Please blow down the water for about 10 seconds to drain away the impurities in the pipe before 

connecting the water source to the electric water heater to avoid blockage of water heater.

If long time no use the unit, check the water heater first before use. Electrify after the water 

flows out stably.

Do not spray water to air switch or heater body directly, to avoid moist.

Please cut off the power in the weather of thunder and rain to avoid damaging the water heater.

If not use for long period of time, please cut off water inlet to prolong the lifespan of the water 

heater.

Check  the  power  cord  connecting  terminals  frequently  to  make  sure  that  they  are  well  and

reliably contacted, no overheating phenomenon, and grounding is good or not.

Disassembly shower head and sealing ring with filter to clean periodically.

DECLARATION: 

this water heater can only be maintained by authorized service personnel, 

incorrect installation and using method may cause serious injury or loss of property.

5. MAINTENANCE

 

WARNING

Do cut off power supply before maintenance, to avoid danger like electric shock.

!

SUGGESTIONS

1. Check whether power 

is cut

2. Contact authorized 

service personnel for 

repair.

1. Rotate “TEMP” knob

2. Repair or replacement 

    the PCB

1. Press the reset handle 

    of the thermal cut out  

    after checking and 

    troubleshooting
2. Change the heating 

    elements

3. Adjustable water flow 
4. Change the flow sensor  
5. Open the flow sensor 

    and clean the rotor 

1. Wait for restoration of 

running water supply;

2. Open the inlet valve of 

running water.

Adjust the heating power 

lower, make the water 

bigger.

Contact authorized service 

personnel for repair.

Contact authorized service 

personnel for repair.

REASONS

1. Power supply error;

2. PCB error;

 

3.

 

Electricity leaks.

1. The “TEMP” knob is off;

2. 

3. The water flow 

insufficient 1.2L/min;

PCB error;

4. Impurities clogging the 

flow sensor of the rotor 

1. The running water 

supply is cut off;

2. The inlet valve of running 

water is not open.

1. Water pressure is not 

stable.

2. Outlet water temperature 

is too high, overheating 

protection again and again.

 

 

 

Electricity leaks.

PUMP error.

Temperture sensor 

is broken

Change the temperture 

sensor 

SYMPTOMS

The heating indicator light 

is off and the outlet 

water is cold.

The heating indicator light 

is on and the outlet 

water is cold.

 

6. TROUBLESHOOTING

Switch on the power 

supply, ELCB indicator 

light is off.

No water flows out from 

the shower head.

Outlet water temperature 

sometimes is hot, 

sometimes is cold.

Pressure can’t be 

increased.

1. The thermal cut out 

is cut off

2. Heating elements 

is broken

 “POWER” indicator light  

is twinkling flicker 

“ELCB”  indicator  light  

is  twinkling  flicker.

Содержание FWH OTTIMO 501CH

Страница 1: ...nstruction Manual For Model Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference FWH SPLASH 301CH WITH PUMP FWH SPLASH 302CH WITH PUMP FWH SPLASH 303RS WITH PUMP FWH OTTIMO 501CH WITHOUT PUMP FWH OTTIMO 502PL WITHOUT PUMP ...

Страница 2: ...ce 11 6 Troubleshooting 12 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electrical water heater to make full use of its excellent performances Please do preserve the instruction manual for future reference ...

Страница 3: ...placement should be done by a qualified technician or engineer or professionals of the similar products In order to avoid a hazard due to inadvertent resetting of the Earth Leakage Circuit Breaker ELCB this appliance must not be supplied through an external switching device such as timer or connected to a circuit that is regularly switched On and Off by the utility Water heater is equipped with ad...

Страница 4: ...Rated Power Rated Current Dia Of Wire Core Air Switch Rated Pressure Minimum Flow Rate Minimum Pressure Maximum Pressure Protection Class Water Proof Class Products Size Knob Quantity 3800W 16A 4mm 20A SPLASH series OTTIMO series I 240V 50Hz 0 MPa 2 Liters minute 0 03 MPa 0 3 MPa IP25 200 400 97 mm 1 1 WARNING The water heater should be earthed before use Please ensure that the resistance of house...

Страница 5: ...or Marker for wateroutlet Water outlet Red Blue PRODUCT STRUCTURE FOR OTTIMO SERIES PRODUCT STRUCTURE FOR SPLASH SERIES Indicator light board Terminal block Silicon control Flow sensor Marker for water inlet Water inlet Wire pressing board Thermal cut out Main control board Heating elements assembly Stainless steel circlip Temperature sensor Marker for wateroutlet Water outlet Red Blue Indicator l...

Страница 6: ...Board Terminal Block Key Board Silicon Control Flow Sensor N PE L G T1 T2 8 5 6 4 7 9 1 2 Silicon Control Temperature Sensor Water Outlet Heating Elements Thermal Cut Out Indicator Light Board Main Control Board Terminal Block Key Board Flow Sensor N PE L G T1 T2 3 8 L N CN6 WIRING DIAGRAM FOR SPLASH SERIES WIRING DIAGRAM FOR OTTIMO SERIES N L RL2 RL1 CN1 ...

Страница 7: ...b to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire pressing plate with screws to primary position ensure that the power cord not be pulled out more than 60N Remove the power cord wire pressing plate and keep the screws Screw the power cord into the jacket for installation of wire ...

Страница 8: ...e Drive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cover with the screws Determine installation position of the unit according to length of power cord position of air switch Distance between bottom and floor should be 1 6m Shower flexible tube should be...

Страница 9: ...er must be used when install the unit Blue marker stands for water inlet red marker stands for water outlet Do not overexert to avoid damaging the water heater NOTE A private power cord should be used for this unit After connecting to electric network please check the earth condition and make sure the earth resistance is 4Ω After all the plumbing is finished connecting open water inlet valve of th...

Страница 10: ...kling flicker no heating it can only be used after the failure is excluded When electricity leakage is tested red and green indicator lights are all off stop heating and close the pump system 4 5 To Adjust Water Temperature Rotate the handle of water flow adjusting valve to adjust to proper water flow Adjust power by rotating knob clockwise rotate power will be increased and water temperature incr...

Страница 11: ...authorized service personnel for repair 1 Rotate TEMP knob 2 Repair or replacement the PCB 1 Press the reset handle of the thermal cut out after checking and troubleshooting 2 Change the heating elements 3 Adjustable water flow 4 Change the flow sensor 5 Open the flow sensor and clean the rotor 1 Wait for restoration of running water supply 2 Open the inlet valve of running water Adjust the heatin...