3.2 Pipelines Connection
③
④
6
PRODUCT STRUCTURE FOR VERTICAL
Install the supply socket in the wall. The requirements for the socket are as follows:250V/10A,
single phase, three electrodes. It is recommended to placed the socket on the right above the
heater. The height of the socket to the ground shall not be less than 1.8m.
If the bathroom is too small, the heater can be installed at another place without sun-scorched and
rain-drenched. However, in order to reduce the pipeline heat losses, the installation position of
the heater shall be closed to the location shall be as near as possible to the heater.
(Fig.2)
Expansion bolt
(with hook)
(Fig.3)
Hot water outlet
Hot water
Cold water
Pressure relief valve
Pressure release hole
Cold water inlet
①
②
③
The dimension of each pipe part is G1/2” ; The massive pressure of inlet should use Pa as
the unit; The minimum pressure of inlet should use Pa as the unit.
Connection of pressure relief valve with the heater on the inlet of the water heater.
In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided
with the heater must be added at the end of the threads to ensure leak proof joints (see
Fig.4).
Power cord
Isolation barrier
connector