3.2 Pipelines Connection

6

PRODUCT STRUCTURE FOR VERTICAL

Install the supply socket in the wall. The requirements for the socket are as follows:250V/10A, 

single phase, three electrodes. It is recommended to placed the socket on the right above the 

heater. The height of the socket to the ground shall not be less than 1.8m.

If the bathroom is too small, the heater can be installed at another place without sun-scorched and 

rain-drenched. However, in order to reduce the pipeline heat losses, the installation position of 

the heater shall be closed to the location shall be as near as possible to the heater.

(Fig.2) 

Expansion bolt 

(with hook)

(Fig.3) 

Hot water outlet

Hot water

Cold water

Pressure relief valve

Pressure release hole

Cold water inlet


The dimension of each pipe part is G1/2” ; The massive pressure of inlet should use Pa as 

the unit; The minimum pressure of inlet should use Pa as the unit.
Connection of pressure relief valve with the heater on the inlet of the water heater.
In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided 

with the heater must be added at the end of the threads to ensure leak proof joints (see 

Fig.4). 

Power cord

Isolation barrier 

connector

Содержание FSH DUAL D50 VH

Страница 1: ...the actual product as the standard Instruction Manual For Model FSH DUAL D30 VH FSH DUAL D50 VH FSH DUAL D80 VH FSH DUAL D100 VH Thank you very much for purchasing our water heater Before installing...

Страница 2: ...g to comply with following instructions included in this pamphlet For more detailed installation and maintenance guidelines please refer to below chapters TABLE OF CONTENTS TITLE PAGE 1 Cautions 2 2 P...

Страница 3: ...er filled fully with water without distortion and cracks Otherwise other strengthening measures shall be adopted The pressure relief valve attached with the heater must be installed at the cold water...

Страница 4: ...dripping from the pressure release hole of the multifunction valves This is a normal phenomenon If there is a large amount of water leak please contact customer care center for repair This pressure r...

Страница 5: ...340 593 262 193 FSH DUAL D30 VH 196 FSH DUAL D50 VH 385 711 296 310 196 FSH DUAL D80 VH 385 1030 296 612 196 FSH DUAL D100 VH 450 915 372 447 196 D C C A B E B A Shell Thermometer Inner tank Thermal i...

Страница 6: ...all a special support Incase of hollow bricks wall ensure to fill it with cement concrete completely After selecting a proper location determine the positions of the two install holes used for expansi...

Страница 7: ...ion position of the heater shall be closed to the location shall be as near as possible to the heater Fig 2 Expansion bolt with hook Fig 3 Hot water outlet Hot water Cold water Pressure relief valve P...

Страница 8: ...ter inlet valve Water inlet valve Running water pipe Mixing valve Water pool Triple joint Shower nozzle Hot water outlet Cold water inlet Power cord Adjusting handle for mixing valve Isolation barrier...

Страница 9: ...ets filled with water When water flows out of the outlet pipe it implies that the heater has been filled fully with water and the outlet valve can be closed Insert the supply plug into the supply sock...

Страница 10: ...maintenance services You can ask the seller for address of the nearest service center 5 MAINTENANCE WARNING Do cut off power supply before maintenance to avoid danger like electric shock 9 WARNING No...

Страница 11: ...act with the professional personnel for repair No water coming out of the hot water outlet The water temperature is too high Water leak 1 The running water supply is cut off 2 The hydraulic pressure i...

Страница 12: ...The product is subject to change without notice Please keep this manual properly...

Отзывы: