Faber FSH DUAL D100 VH Скачать руководство пользователя страница 11

6. TROUBLESHOOTING

NOTE

Parts illustrated in this use and care manual are indicative only, parts provided with the 

product may differ with illustrations.This product is intended for household use only. 

Specifications are subject to change without notice.

10

Failures

Reasons

Treatment

The heating indicator

light is off.

Failures of the temperature 

controller.

Contact with the professional

personnel for repair.

No water coming out 

of the hot water outlet.

The water temperature

is too high.

Water leak.

1. The running water supply

    is cut off.

2. The hydraulic pressure is 

    too low.

3. The inlet valve of running

    water is not open.

1. Wait for  restoration of 

    running water supply.

2. Use the heater again when 

    the hydraulic pressure is 

    increased.

3. Open the inlet valve of

    running water.

Failures of the temperature 

control system.
Seal problem of the joint 

of each pipe.

Contact with the professional

personnel for repair.
Seal up the joints.

Содержание FSH DUAL D100 VH

Страница 1: ...the actual product as the standard Instruction Manual For Model FSH DUAL D30 VH FSH DUAL D50 VH FSH DUAL D80 VH FSH DUAL D100 VH Thank you very much for purchasing our water heater Before installing...

Страница 2: ...g to comply with following instructions included in this pamphlet For more detailed installation and maintenance guidelines please refer to below chapters TABLE OF CONTENTS TITLE PAGE 1 Cautions 2 2 P...

Страница 3: ...er filled fully with water without distortion and cracks Otherwise other strengthening measures shall be adopted The pressure relief valve attached with the heater must be installed at the cold water...

Страница 4: ...dripping from the pressure release hole of the multifunction valves This is a normal phenomenon If there is a large amount of water leak please contact customer care center for repair This pressure r...

Страница 5: ...340 593 262 193 FSH DUAL D30 VH 196 FSH DUAL D50 VH 385 711 296 310 196 FSH DUAL D80 VH 385 1030 296 612 196 FSH DUAL D100 VH 450 915 372 447 196 D C C A B E B A Shell Thermometer Inner tank Thermal i...

Страница 6: ...all a special support Incase of hollow bricks wall ensure to fill it with cement concrete completely After selecting a proper location determine the positions of the two install holes used for expansi...

Страница 7: ...ion position of the heater shall be closed to the location shall be as near as possible to the heater Fig 2 Expansion bolt with hook Fig 3 Hot water outlet Hot water Cold water Pressure relief valve P...

Страница 8: ...ter inlet valve Water inlet valve Running water pipe Mixing valve Water pool Triple joint Shower nozzle Hot water outlet Cold water inlet Power cord Adjusting handle for mixing valve Isolation barrier...

Страница 9: ...ets filled with water When water flows out of the outlet pipe it implies that the heater has been filled fully with water and the outlet valve can be closed Insert the supply plug into the supply sock...

Страница 10: ...maintenance services You can ask the seller for address of the nearest service center 5 MAINTENANCE WARNING Do cut off power supply before maintenance to avoid danger like electric shock 9 WARNING No...

Страница 11: ...act with the professional personnel for repair No water coming out of the hot water outlet The water temperature is too high Water leak 1 The running water supply is cut off 2 The hydraulic pressure i...

Страница 12: ...The product is subject to change without notice Please keep this manual properly...

Отзывы: