background image

Manual e-MatriX 800 

-------------------------------------------------------------------------------------------------------------------------------------- 

14 < 

<

 

<

 

<

 

12

 

Trouble shooting 
 

Symptom 

Cause 

Action 

The flame effect will not start. 

Mains plug is not plugged in. 
 
 
Low water level. 
 
The transducers) are not connected 
properly. 

Check plug is connected to wall 
socket correctly. 
 
See Chapter 8.3. 
 
Check that the connector(s) is 
inserted correctly see fig. 7.0. 

e-MatriX will not start or stopped 
working and the LED’s continuously 
to blink twice. 

Low water level. 
 
 
 
 
 
 
 
 
The absorption valve is activated 

See Chapter 8.3. 
 
Switch the mains switch of the 
Control box to the OFF position. 
Check all connections on water 
leakage.  
 
Check that the ball valves are open.  
 
See Chapter 10.3. 

e-MatriX will not operate, the LED’s 
continuously to blink once every 
eight seconds. 

Water level too high. 

Check the electromechanical valve 
in the Control box.

 

e-MatriX will not operate, the LED’s 
continuously to blink four times. 

Water filling time is too long. 

Switch the mains switch of the 
Control box to the OFF position and 

heck all connections on water 
leakage.  
 
Close the ball valves and check the 
mesh filter, by unscrewing the base 
of it to see that it is not clogged with 
dirt and debris.

 

The flame effect is too low on the 
highest setting. 

The transducers and/or air filter are 
dirty. 

Call for maintenance. 

The flame effect is too high and 
there is too much smoke. 

The extract fan doesn’t work 
anymore. 

Check if the fan, mounted at the top 
inside the fire, is running. 

Remote is not working. 

Low batteries. 
 
Remote isn’t paired to receiver. 
 
Distance to fire too big 

Place new batteries. 
 
See Chapter 8.2.1. 
 
See Chapter 9 (remote control). 

 

 

 

Содержание e-MatriX 800

Страница 1: ...Manual e MatriX 800 40011677 1742 Manual e MatriX ENG ...

Страница 2: ...Manual e MatriX 800 2 Registration plate ...

Страница 3: ...Manual e MatriX 800 3 1 0 1 1 1 2a 1 2b ...

Страница 4: ...Manual e MatriX 800 4 2 0a 2 0c 2 0b 2 1a 2 1b ...

Страница 5: ...Manual e MatriX 800 5 2 1c 2 2 3 0 3 1 4 0 4 1 4 2 ...

Страница 6: ...Manual e MatriX 800 6 5 0 ...

Страница 7: ...Manual e MatriX 800 7 6 0 7 0 7 1 7 2 7 3 7 4 8 0 ...

Страница 8: ...ith the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 these cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC This declaration is invalid if changes are made to the fire 2 Safety instructions Do not use outdoors Do not use in the immediate surroundings of a bath shower or swimming pool ...

Страница 9: ...ad the DC cable inside the Engine to the Control box and connect it Max cable length from the center of the fire to the left 1 5m Max cable length from the center of the fire to the right 1 0m Connect the supplied mains lead 4 1 2 Water connection This appliance is equipped with the following overflow protections o Electromechanical valve in the Control box which is sent by an overflow sensor in t...

Страница 10: ... not necessary to remove the side glass First remove the front glass see Chapter 5 1 or 5 2 Place a suction cup and remove the side glass see fig 2 2 For replacing the glasses repeat the steps in reverse order 6 Removing fuel bed Never lift up the fuel bed without using the supplied handles Keep these handles for future use Remove the front glass see Chapter 5 1 or 5 2 Cover the frame to avoid scr...

Страница 11: ...s are open and turn on the water supply Switch the fire on by pressing the mains switch to the ON position and pressing the button see Chapter 8 1 and 8 2 o If the water level is high enough the flames will automatically start after 45 seconds o If the water level isn t high enough the LED s continuously to blink twice after 45 seconds Press the mains switch to the OFF position wait 5 seconds and ...

Страница 12: ...nd or the running hours and therefore can differ from the above mentioned 10 1 1 Cleaning water sump Always press the mains switch to the OFF position and disconnect the power supply see fig 4 0 Never use abrasive cleaners Remove the front glass see Chapter 5 1 or 5 2 Remove the fuel bed see Chapter 6 Disconnect the fill cap by turning it clockwise see fig 5 0 L and 7 0 Disconnect the 2 connectors...

Страница 13: ...cer upwards out of its holder Place the new transducers and repeat the steps above in reverse order 10 1 4 Cleaning mesh filter Turn off the water supply Close the ball valves Unscrew the base and clean the filter inside 10 1 5 Replacing in line filter Turn off the water supply Close the ball valves Replace the in line filter Place it in correct alignment there s a flow direction marking on the fi...

Страница 14: ...blink once every eight seconds Water level too high Check the electromechanical valve in the Control box e MatriX will not operate the LED s continuously to blink four times Water filling time is too long Switch the mains switch of the Control box to the OFF position and heck all connections on water leakage Close the ball valves and check the mesh filter by unscrewing the base of it to see that i...

Страница 15: ...Manual e MatriX 800 15 13 Dimensional Drawings 13 1 e MatriX 800 650 I 13 2 e MatriX 800 650 IIL ...

Страница 16: ...Manual e MatriX 800 16 ...

Страница 17: ...Manual e MatriX 800 17 13 3 e MatriX 800 650 IIR ...

Страница 18: ...Manual e MatriX 800 18 13 4 e MatriX 800 650 III ...

Страница 19: ...Manual e MatriX 800 19 13 5 Control box ...

Страница 20: ...Manual e MatriX 800 20 13 6 Wall bracket ...

Страница 21: ...Manual e MatriX 800 21 13 7 Remote access door ...

Страница 22: ...Manual e MatriX 800 22 ...

Страница 23: ...Manual e MatriX 800 23 ...

Страница 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: