Version 12/04 - Page 6

  

DUCTLESS 

INSTALLATION  DIMENSIONS

upper 

chimney 

cover

ductless 

lower 

chimney 

cover

canopy

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

cabinet base

10" min

16 

1/8”

 max

22"

3/8”

36”

22"

x

also consult cooktop

manufacturer's recommendation

  

(not vented to the outside)

FIGURE 4B 

DUCTLESS

 INSTALLATIONS

The Diamante chimneys are adjustable and 

designed  to  meet  varying  ceiling  heights 

as  indicated  in 

FIGURE  4B

.    For  ductless 

installations,  the  chimneys  can  be  adjusted 

for ceilings between 7' 11 3/8" and 8' 11 1/2" 

depending on the distance between the bottom 

of the hood and the cooktop

 (distance x)

.

For shorter ceilings, have the chimney cover(s) 

cut at a sheet metal shop.    For higher ceiling 

installations, the 

High Ceiling Chimney Kit

 

includes a new 40” upper chimney which would 

replace the 16 1/8” upper chimney that came 

with the hood.

Note: If 

24" or 30" High Backsplash

 is being 

installed,  the  distance  between  the  bottom 

of the hood and the cooktop 

(DISTANCE X 

IN FIGURE 4B)

 is equal to the  height of the 

Backsplash

.

min & max ceiling height examples

x = 30"

min

8' 

5 3/8"

max

8' 

11 1/2"

x = 28"

min

8' 

3 3/8"

max

8' 

9 1/2"

x = 26"

min

8' 

1 3/8"

max

8' 

7 1/2"

x = 24"

min

7' 

11 3/8"

max

8' 

5 1/2"

38 1/8"

Содержание DIAMANTE

Страница 1: ...Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POURMINIM...

Страница 2: ...ng means to prevent power from being switched on accidentally Whentheservicedisconnectingmeanscannotbelocked securely fasten a prominent warning device such as a tag to the service panel CAUTION For G...

Страница 3: ...es conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et A...

Страница 4: ...EEDED FOR INSTALLATION 2 Conduit Connectors Power Supply Cable 1 Wall or Roof Cap All Metal Ductwork OPTIONAL ACCESSORIES AVAILABLE Backsplash Choose either 24 or 30 high mounts to the wall beneath th...

Страница 5: ...uld replace the 16 1 8 upper chimney that came with the hood Note If 24 or 30 High Backsplash is being installed the distance between the bottom of the hood and the cooktop DISTANCE X IN FIGURE 4A is...

Страница 6: ...ys can be adjusted for ceilings between 7 11 3 8 and 8 11 1 2 dependingonthedistancebetweenthebottom of the hood and the cooktop distance x Forshorterceilings havethechimneycover s cut at a sheet meta...

Страница 7: ...tall the MOUNTING SCREWS into the wall leaving about 1 4 gap between the wall and the head of the screw 8 For ducted installations determine and make all necessary cuts in the wall for the ductwork In...

Страница 8: ...upply to the White lead of the rangehoodwithatwist ontypewireconnector AttachtheBlacklead of the power supply to the Black lead of the rangehood with a twist on type wire connector Attach the Power Su...

Страница 9: ...hood Remove the lamp from the light support and replace with new lamp Replace the light support and x it into place with the 2 screws FIGURE 12 WARRANTY SERVICE All Faber products are warranteed agai...

Отзывы: