Faber Concept Скачать руководство пользователя страница 13

13

EN

Electrical connection

ELECTRICAL SHOCK HAZARD

• Disconnect power before making electrical connctions.
• Connect ground wire to green ground screw in terminal box.

!

WARNING

green

ground

screw

hood wiring

purple wiring red wiring

hood wiring

black wiring

white wiring

power

supply

conduit

light wiring

exterior

blower

wiring

twist-on

connectors

blue wiring

brown wiring

• Connect the red wire of the Light cable with the red lead in the hood

using a twist-on connector; connect the purple wire of the Light cable
with the purple lead in the hood using a twist-on connector.

• Connect the blue blower wire with the blue lead in the hood using a twist-

on connector; connect the brown blower wire with the brown lead in the
hood using a twist-on connector.

• Connect the ligth unit to the ground using one of the following two alter-

native ways:
a- Connect the domestic green ground wire under the unused green ground

screw belonging to the light unit wiring box using a listed conduit
connector.

b- Connect one end of the green ground wire (max lenght 10 yards using

14 awg wire) under the unused green ground screw belonging to the
light unit wiring box and the other end under the unused green ground
screw belonging to the range hood wiring box.

• Connect the green ground wire (from exterior blower and from power

supply cable) under the unused green ground screw.

• Tighten strain relief screws.
• Connect the white wire of the power supply conduit with the white lead

in the hood using a twist-on connector; connect the black wire of the
power supply conduit with the black lead in the hood using a twist-on
connector.

• Place the suction panel so that the connection flat wiring for the hood

controls passes through the specific opening in the hood body.

• Fix the suction panel to the hood body fastening the screws removed

earlier.

• Open the suction cover using the lever provided.
• Connect the flat connection wiring coming from the hood controls with

the connector piece placed close to the terminal box. Only in case of the
bottom air outlet configuration remove the protection cover from the
connector piece on the opposite side of the terminal box.

• Fix the terminal box cover again and fasten the 2 screws removed earlier.
• Replace the metal grease filters in their housings.
• Close the suction panel.

Содержание Concept

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner The homeowner must keep these instructions for future reference and for local electrical inspectors use Concept Remote Blower ...

Страница 2: ...2 EN CONTENTS WARNING 3 CHARACTERISTICS 5 INSTALLATION 8 USE 13 MAINTENANCE 14 ...

Страница 3: ...G REQUIREMENTS Determine which venting method is best for your application Ductwork can extend either through the wall or the roof The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance The size of the ductwork should be uniform Do not install two elbows together Use duct tape to seal all joints in the ductwork system Use caulking to seal e...

Страница 4: ...dous or Explosive Materials and Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation Work And Electrical Wiring Must Be Done By Qualified Person s In Accordance With All Applicable Codes And Standards Including Fire Rated Construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel...

Страница 5: ...Rear remote motor connection panel 4 1 Top air outlet flange with valve 5 1 Top air outlet plug 10 1 Light 11 4 Support arms 12 2 Bush masking plug 13 2 Arm support bush A 10 Screws 3 5 x 16 C 4 Screws 5 x 70 D 4 Wall Plugs ø 10 E 2 Screwsfor wall plugs ø 5 F 2 Wall Plugs ø 5 G 4 Grub screws Dimensions 28 7 16 48 1 8 5 29 32 98 7 16 118 1 8 22 3 4 5 29 32 ...

Страница 6: ...6 EN Dimensional chart Hood Distance from the Hob ...

Страница 7: ...7 EN Dimensional chart LIGHT ...

Страница 8: ... side position U Concerning the ductrun consider the figures in the following scheme bearing in mind that the rear hole P serves only for the rear air outlet configuration CALCULATE THE DUCTRUN LENGTH The ductwork length should not exceed 35 equivalent feet for 3 1 4 X 10 duct or 55 equivalent feet for 9 or 10 round duct Calculate the length of the ductwork by adding the equivalent feet listed in ...

Страница 9: ...ng template provided mark the necessary holes and drill them ø15 16 TOP OR BOTTOM AIR OUTLET CONFIGURATION The hood is manufactured with the air outlet at the top Fit the flange with non return valve onto the air outlet position of the built in hood body case In case of the bottom air outlet configuration turn the built in hood body case 180 before fixing it to the wall ...

Страница 10: ...ow in the wall paying attention that the external edge of the built in case adheres perfectly to the wall It is necessary that the built in case is precisely levelled both horizontally and vertically and that the air outlet flange is correctly placed inside the ductrun BEFORE INSTALLING THE HOOD IT WILL BE NECESSARY TO WAIT UNTILL THE BUILT IN HOOD BODY CASE WALLING PROCESS IS COMPLETELY TERMINATE...

Страница 11: ...providing thus for a passage of the electrical connection for the lighting unit Place the hood body inside the built in case paying attention that the screws of the built in case fall to the gaps of the hood body Once the screws have reached the gaps it is necessary to fasten them in order to definitively fix the hood body inside the built in case It is necessary to make sure that the hood body ai...

Страница 12: ...screws C Fix the two support arm connection bushes to the wall Make electrical connection Connect the red wire in the Light unit with the red lead in the hood using a twist on connector connect the purple wire in the Light unit with the purple lead in the hood using a twist on connector Connect the green ground wire to the unused green ground screw Replace the top cover fixing it in place with the...

Страница 13: ...10 yards using 14 awg wire under the unused green ground screw belonging to the light unit wiring box and the other end under the unused green ground screw belonging to the range hood wiring box Connect the green ground wire from exterior blower and from power supply cable under the unused green ground screw Tighten strain relief screws Connect the white wire of the power supply conduit with the w...

Страница 14: ...CTIONS L 0 1 Light Turns lighting on and off T1 0 1 Motor Fixed First speed When pressed for about 2 seconds the motor is switched off T2 Speed Fixed Second speed T3 Speed on Third speed T4 Speed Fixed Max speed Flashing Intensive speed Suitable for the strongest cooking vapours and odours The function becomes active when the button is pushed for about 2 seconds After 10 minutes of functioning it ...

Страница 15: ...ric Diagram Lighting LIGHT REPLACEMENT 20 W halogen light Extract the lamp from the Support Replace with another of the same type making sure that the two pins are properly inserted in the lamp holder socket holes ...

Страница 16: ...436002499_02 041103 ...