I n s t a l l a t i o n I n s t r u c t i o n s
7
4 Preparation and installation
instructions
4.1
Gas connection
Calculate/Size the pipe so that no pressure drop occur in the gas
pipe.
4.2
Elektrical connection
The power supply must comply with the applicable local standards.
A 6 Volt adapter is used.
For this, a wall socket 230VAC/50Hz must be installed near the fire.
4.3
Preparing the fire
•
Remove frame (fig 1.1 and 1.2)and glass and take the
packaged parts from the fire.
•
Store frame and glass in a safe place.
•
Prepare the gas connection on the regulator
4.4
Positioning the fire
Take the installation requirements into account (see Chapter 3).
•
Put and level the fire on the right place and mount it at the
wall with 4 screws. (Fig. 1.3)
•
There are no levelling feet underneath the fire.
4.5
Installing the flue materials
•
When penetrating a wall the opening must be at least 5mm
larger than the diameter of the discharge material.
See Chapter 13 for the height of this hole.
•
Horizontal sections should be installed with a slope towards
the fire (3 degrees).
•
Build the system from the fire. (Fig. 1.4). The telescopic part
ensures an easy installation.
>
Please note:
The telescopic part must be fixed with a self-tapping screw.
•
The wall terminal can be cut.
4.6
Positioning of the casing
If possible, carry out a performance test as described in chapter 7
on the fire before placing the casing., (fig. 1.5).
Put the casing on the supports left and right and screw it according
to fig. 1.1 en 1.2.
4.7
Positioning the cover plate
Put the cover plate on top of the casing. (See fig. 1.6).
4.8
Placing the glass frame
Put the 4 brackets of the glass frame in the slotted holes of the
casing and lower the glass frame. (See fig. 1.7).
Prevent damaging of the casing!
Removing the glass frame goes in reverse order.
5 Removing the glass
•
Remove the glass frame. (See par. 4.8)
•
Place the suction cup onto the glass. (Fig. 3.1 and 3.3)
•
Remove the glass clamps by using a screw driver.(Fig. 3.2)
•
Move the glass forwards.
To replace the glass repeat the process in reverse order.
> Note:
Remove the fingerprints from the glass these will burn in and
cannot be removed after the fire is used.
6 Placing the decoration material
It is not permitted to use other or to add more material in the
combustion chamber.
Keep the pilot light always free of decoration material!
Do not place all decoration material at one time on the burner; the
fabric parts can block it.
6.1
Log set
•
Spread the vermiculate preferably by hand over the tube
burners. The surface of the pebbles may be very slightly
elevated from the burner plate but it should be level
throughout the entire length.
•
Place the logs as specified. (see Fig. 4.1 or included log set
card)
•
It is optional whether you apply chips to the combustion
chamber or not. Prevent chips from covering the burner, this
has a negative effect on the fire image.
Start the fire as described in the user manual. Check if the flame
distribution is good. Move the logs a little if necessary, until a good
flame distribution is achieved.
7 Checking the installation
7.1
Checking the ignition of the main burner and the
pilot flame
Ignite the fire as described in the user manual.
•
Check that the pilot flame is well above the main burner and
not covered by chips.
•
Check the ignition of the main burner on full and small
setting. (ignition must be smooth and quiet).
7.2
Checking for gas leaks
Check with a gas leak finder or spray all connections and pipes for
gas leakage.
7.3
Checking the burner pressure and primary
pressure
Check that the burner pressure and primary pressure match the
information listed in the manual, Chapter 11 Technical specificati-
ons.
Содержание Concept l-450
Страница 1: ...Concept l 450 40011643 1550 Concept l 450 ENG ...
Страница 2: ...I n s t a l l a t i o n I n s t r u c t i o n s 2 1 1 1 2 ...
Страница 3: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 1 6 1 3 1 4 1 5 ...
Страница 4: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 1 7 2 1 2 2 3 1 B A 2 1 ...
Страница 5: ...I n s t a l l a t i o n I n s t r u c t i o n s 5 4 1 3 2 3 3 ...
Страница 14: ...1 4 I n s t a l l a t i o n I n s t r u c t i o n s 14 Dimensional drawings 14 1 Concept I 450 ...
Страница 15: ...1 5 I n s t a l l a t i o n I n s t r u c t i o n s 14 2 Position gasvalve and wall terminal ...
Страница 16: ...1 6 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen Dealerinfo ...