I n s t a l l a t i o n   I n s t r u c t i o n s

7

4  Preparation and installation 

 instructions 

4.1  

Gas connection

Calculate/Size the pipe so that no pressure drop occur in the gas 

pipe.

4.2  

Elektrical connection

The power supply must comply with the applicable local standards.

A 6 Volt adapter is used.

For this, a wall socket 230VAC/50Hz must be installed near the fire.

4.3  

Preparing the fire

• 

Remove frame (fig 1.1 and 1.2)and glass and take the  

 

 

packaged parts from the fire.

• 

Store frame and glass in a safe place.

• 

Prepare the gas connection on the regulator

4.4  

Positioning the fire

Take the installation requirements into account (see Chapter 3).

• 

Put and level the fire on the right place and mount it at the    

 

wall with 4 screws. (Fig. 1.3)

• 

There are no levelling feet underneath the fire.

4.5  

Installing the flue materials

• 

When penetrating a wall the opening must be at least 5mm   

 

larger than the diameter of the discharge material.

 

See Chapter 13 for the height of this hole.

• 

Horizontal sections should be installed with a slope towards  

 

the fire (3 degrees).

• 

Build the system from the fire. (Fig. 1.4). The telescopic part  

 

ensures an easy installation.

Please note: 

 

The telescopic part must be fixed with a self-tapping screw.

• 

The wall terminal can be cut.

4.6  

Positioning of the casing

If possible, carry out a performance test as described in chapter 7 

on the fire before placing the casing., (fig. 1.5).

Put the casing on the supports left and right and screw it according 

to fig. 1.1 en 1.2.

4.7  

Positioning the cover plate

Put the cover plate on top of the casing. (See fig. 1.6).

4.8  

Placing the glass frame

Put the 4 brackets of the glass frame in the slotted holes of the 

casing and lower the glass frame. (See fig. 1.7). 

Prevent damaging of the casing!

Removing the glass frame goes in reverse order.

5 Removing the glass

• 

Remove the glass frame. (See par. 4.8)

• 

Place the suction cup onto the glass. (Fig. 3.1 and 3.3)

• 

Remove the glass clamps by using a screw driver.(Fig. 3.2) 

• 

Move the glass forwards.

To replace the glass repeat the process in reverse order.

> Note:

Remove the fingerprints from the glass these will burn in and 

cannot be removed after the fire is used.

6 Placing  the decoration material

It is not permitted to use other or to add more material in the 

combustion chamber.

Keep the pilot light always free of decoration material!

Do not place all decoration material at one time on the burner; the 

fabric parts can block it.

6.1  

Log set

• 

Spread the vermiculate preferably by hand over the tube    

 

burners. The surface of the pebbles may be very slightly    

 

elevated from the burner plate but it should be level  

 

 

throughout the entire length.

• 

Place the logs as specified. (see Fig. 4.1 or included log set  

 

card)

• 

It is optional whether you apply chips to the combustion    

 

chamber or not. Prevent chips from covering the burner, this  

 

has a negative effect on the fire image.

Start the fire as described in the user manual. Check if the flame 

distribution is good. Move the logs a little if necessary, until a good 

flame distribution is achieved.

7 Checking the installation

7.1  

Checking the ignition of the main burner and the    

 

 

pilot flame

Ignite the fire as described in the user manual.

• 

Check that the pilot flame is well above the main burner and  

 

not covered by chips. 

• 

Check the ignition of the main burner on full and small  

 

 

setting. (ignition must be smooth and quiet).

7.2  

Checking for gas leaks

Check with a gas leak finder or spray all connections and pipes for 

gas leakage.

7.3  

Checking the burner pressure and primary  

 

  pressure

Check that the burner pressure and primary pressure match the 

information listed in the manual, Chapter 11 Technical specificati-

ons. 

Содержание Concept l-450

Страница 1: ...Concept l 450 40011643 1550 Concept l 450 ENG ...

Страница 2: ...I n s t a l l a t i o n I n s t r u c t i o n s 2 1 1 1 2 ...

Страница 3: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 1 6 1 3 1 4 1 5 ...

Страница 4: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 1 7 2 1 2 2 3 1 B A 2 1 ...

Страница 5: ...I n s t a l l a t i o n I n s t r u c t i o n s 5 4 1 3 2 3 3 ...

Страница 6: ...e obstructed and particular care must be taken when placing the logs pebbles or stones which are supplied with the fire The unit is for atmosphere and heating purposes This means that all surfaces including the glass can be very hot over 100 C exceptions to this are the bottom of the fire and the control elements Do not place any combustible materials within 0 5m of the radiation area of the fire ...

Страница 7: ...maging of the casing Removing the glass frame goes in reverse order 5 Removing the glass Remove the glass frame See par 4 8 Place the suction cup onto the glass Fig 3 1 and 3 3 Remove the glass clamps by using a screw driver Fig 3 2 Move the glass forwards To replace the glass repeat the process in reverse order Note Remove the fingerprints from the glass these will burn in and cannot be removed a...

Страница 8: ... 1 air supply 2 flue gas The ratio CO2 and CO must not be greater than 1 100 Example CO2 is 4 and CO is 400ppm measured at the highest point If the ratio is greater than 1 100 or exhaust gases are measured in the supply air then also check above points 8 Instructions for client Recommend that the unit should be checked annually by a qualified specialist to ensure the safe use and to guarantee a lo...

Страница 9: ...0 127 0 164 at 15º C and 1013 mbar gr h 320 310 Burner pressure at full mark mbar 10 24 8 31 6 Injector main burner mm 1 9 1 1 1 1 Reduced input restraint mm 1 1 0 85 0 85 Pilot flame OP NG9030 OP LPG9222 OP LPG9222 Code pilot flame injector Diameter outlet inlet mm 100 150 100 150 100 150 Gas controle valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical connection V 230 230 230 Batteries re...

Страница 10: ...lets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof terminal Only for existing Chimney connection Extension pipe over roof 12 Terminal position Please note These rules apply only for the proper functioning of the unit for ventilation and environmental protection y...

Страница 11: ...ut of a small piece from the sparking plug Tie wraps removed Cable is free from any metal parts 4x 1 5V AA Alkaline Thermocouple circuit is interrupted check 8 wire cable from receiver to the gas valve If the wire on the bottom of the gas valve is not broken or stuck and makes a ground contact Motor gas valve doesn t work Micro switch on gas valve doesn t work 3 short beep s 1 long beep Faulty sol...

Страница 12: ...lot burner is leaking Gasket between burner unit is leaking Glass seal is leaking Flue parts aren t 100 connected check flue system Replace batteries in the receiver Check the distance from thermocouple to pilot flame Measure the mvolts over the thermocouple required min 4mvolts over black and ground contact Flame stays blue lift from the burner and fire switch of Check flue calculation horizontal...

Страница 13: ...aulty parts RESET the receiver Gas vlave broken poor or loose contact Short circuit in wiring Install a ground cable from the gas valve to the appliance Optional Step burner function can be turned ON and OFF only with remote RESET the receiver Check the wiring from solenoid valve to receiver Faulty solenoid valve Faulty receiver Repaire the wiring Replace solenoid valve Replace receiver ...

Страница 14: ...1 4 I n s t a l l a t i o n I n s t r u c t i o n s 14 Dimensional drawings 14 1 Concept I 450 ...

Страница 15: ...1 5 I n s t a l l a t i o n I n s t r u c t i o n s 14 2 Position gasvalve and wall terminal ...

Страница 16: ...1 6 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen Dealerinfo ...

Отзывы: