Safety and general information 

Before installation, ensure that the local distribution conditions (identification of the type of 

gas and pressure) and the adjustment of the appliance are compatible. 

This gas appliance is factory set and can not be adjusted. 

This appliance does not contain any component manufactured from asbestos or any asbestos 

related products. 

Ventilation 

This appliance is room-sealed and doesn't require purpose provided ventilation. 

Never use the appliance if it has a broken glass. 

General safety 

It is the law in the UK that all gas appliances, are installed by a competent person in 

accordance with the Gas Safety (Installation and Use) Regulations (as amended), the 

relevant British Standards for Installation work, Building Regulations, Codes of Practice and 

the manufacturers instructions.  

Always use an additional guard if there are elderly, infirm or children in the same room of 

the appliance. 

The installation should also be carried out in accordance with the following where relevant:  

 

BS5871 Part1 

 

BS5440 Parts 1 & 2 

 

BS1251 

 

Building Regulations Document J (as applicable) 

 

Building Regulations and Standards issued as relevant by the Department of the 

Environment or the Scottish Development Department 

 

In the Republic of Ireland installation should be carried out in accordance with IS813, 

ICP3, IS327, Building Regulations, Codes of Practice, the manufacturers instructions 

and all other regulations in force 

Failure to comply with the above could leave the installer liable to prosecution and 

invalidate the appliance warranty. 

Содержание Bright

Страница 1: ...Bright Installation Guide IRL UK 40010660 0811 ...

Страница 2: ...1 UK IRL General 1 1 1 2 1 3 ...

Страница 3: ... 2 UK IRL 1 4 1 5 1 6 A B D C ...

Страница 4: ...3 UK IRL Bright 2 1 2 2 2 3 2 4 Build in frame ...

Страница 5: ... 4 UK IRL De mounting the Glass 3 1 3 2 3 3 3 4 3 5 3 6 3 7 ...

Страница 6: ...lacing the Log Twig set or pebbles 12 4 8 Placing the glass 12 4 9 Removing the glass 12 5 Commissioning functional checks 13 5 1 Pilot ignition check 13 5 2 Check functional burner and pilot burner 13 6 Handing over final check and customer briefing 14 7 Servicing 14 7 1 Routine annual servicing 14 7 2 Cleaning the glass 14 7 3 Cleaning the combustion chamber and burner 15 Appendix A Example calc...

Страница 7: ...ss configuration available Special features Room sealed appliance inlet and outlet are led to the outside using a natural draught concentric pipe system 100 mm 150 mm no power fan required Air supply and flue gases go to outside atmosphere through wall or roof A horizontal extension is possible see appendix A and B Remote Control is standard Meets the requirements of the European Gas Appliance Dir...

Страница 8: ...ons as amended the relevant British Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions Always use an additional guard if there are elderly infirm or children in the same room of the appliance The installation should also be carried out in accordance with the following where relevant BS5871 Part1 BS5440 Parts 1 2 BS1251 Building Regulations Doc...

Страница 9: ...should be born in mind when installing the appliance 3 1 False chimney breast The appliance must be installed in a non combustible false chimney breast For the dimensions of the appliance see appendix F Keep the following in mind do not place the appliance on combustible materials or carpets both walls have to be made of non combustible material e g Promatec do not place the lintel surround or mar...

Страница 10: ...inal counts for 1 meter 3 3 Flue restrictor If applicable in the table of appendix B is also stated the size of a flue restrictor This restrictor needs to be fitted in the combustion chamber when placing the appliance Normally the smallest flue restrictor is fitted at production 3 4 Terminal position Verify if the required terminal position meets the local installation regulations regarding distur...

Страница 11: ...tions as air supply where a flexible stainless steel liner to BS715 of 100 mm performs the flue function Requirements Any existing chimney used as an air supply must only service this appliance A chimney that has previously been used for solid fuel must be swept before use The existing chimney needs to be airtight The existing chimney needs to have an opening of min 150 x 150 mm The chimney needs ...

Страница 12: ... Determine the position and height where the appliance has to be placed Pre adjust the total height of the appliance considering the desired height see figure 1 5 There are two ways to adjust the height o Rough adjustment by removing the nut and bolt Shift the leg in steps of 30mm and replace the nut and bolt o Fine adjustment by adjusting the couple legs 4 3 Placing the appliance Check paragraph ...

Страница 13: ...etween the logs or twigs never spread over more than one layer Always check if the pilot light can be seen 4 8 Placing the glass Two suction pads are delivered with the appliance to make placing removal easier Always clean the suction lifters before use Place the suction lifters on the glass and bring the handles towards each other fig 3 1 Slide the top of the glass carefully in the glass opening ...

Страница 14: ...d pressure Perform this measuring when the appliance burns on full capacity and when only the pilot ignition burns When the pressure is too low check if the gas pipes are made of material with the right diameter When the pressure is too high more than 5 mBar overpressure you can t install the appliance and you should contact your gas company Always check the burner pressure when the functional pre...

Страница 15: ...before commencing any servicing Always test for gas soundness after refitting the appliance 7 1 Routine annual servicing Clean if necessary a the pilot system b the burner c the combustion chamber d the glass Check the log layout and replace the embers if applicable Do the operating test as described in chapter 5 Check the flue system and terminal for damage and soundness visual inspection 7 2 Cle...

Страница 16: ...re burnt in Place the glass in front of the appliance and fix the glass frame or use the glass clamps 7 3 Cleaning the combustion chamber and burner If the burner is visibly damaged this can affect the distribution of the flame if so then replace the burner Remove the front glass and log holder if applicable Break the gas supply at the control valve Unscrew the burner assembly and take them out of...

Страница 17: ... A 1 m Roof mounted terminal 1 m Total effective height 2 m Always check if the calculated situation is allowed see appendix B Flue restrictor Calculation 2 Calculation horizontal extension fig 2b Flue length J L 0 5 0 5 1 m Elbows K M 2m 2m 4 m Terminal 1 m Total horizontal extension 6 m Calculation effective height Hvert Flue length H 1 m Always check if the calculated situation is allowed see a...

Страница 18: ...when the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is pre installed Horizontal length m Bright 0 1 2 3 4 5 6 0 X X X X X X X 0 5 X X X X X X X 1 0 0 0 0 X X X 1 5 0 0 0 0 0 X X 2 30 0 0 0 0 0 X 3 30 30 0 0 0 0 0 4 40 30 30 0 0 0 0 5 40 40 30 30 0 0 0 6 50 40 40 30 30 0 0 7 50 50 40 40 30 30 X 8 50 50 40 40 40 X X 9 65 50 50 40 X X X 10 65 65 50 ...

Страница 19: ...mp every 2m so the weight of the pipes is not resting onto the appliance The outside of the pipe can become hot 140 degrees Stay 50 mm away from wall surface or sealing Make sure to provide sufficiently heat resistant isolation when going through the wall or roof Because of expansion or cooling down the concentric pipes can turn loose It is recommended to fix the spring clip with a self tapping sc...

Страница 20: ...fficiency class 2 2 Inlet pressure Mbar 20 37 Gas rate l h 917 330 Gas rate gram h 620 Working pressure high Mbar 11 0 32 4 Injector size Mm Bray 800 Bray 280 Reduced input restraint Mm 2 10 1 10 Pilot assembly SIT 145 SIT 145 Code Nr 36 Nr 23 Flue system Flue size Mm 100 150 100 150 Std Flue restrictor Mm 30 30 Gas control GV 60 C4E3M6M C4D3M6M Gas connection Nut olive 8 mm 8 mm at 15ºC and 1013 ...

Страница 21: ... 20 UK IRL Appendix E Dimensions Bright ...

Страница 22: ...21 UK IRL Appendix F Dimensions Convection grid ...

Страница 23: ... 22 UK IRL Appendix G Dimensions Service hatch ...

Страница 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: