Faber BRANDE 82 Скачать руководство пользователя страница 10

 

10

 
Complaints can only be accepted when all the following data is available:  

-

  Production number (see item)  

-

  Purchase proof or copy of the purchase receipt from the Faber authorised 

dealer  

-

  Acceptance record from the chimney sweep  

-

  In the case of malfunction, the acceptance record from the print-out device 

of the chimney sweep and the chimney calculation according to DIN 4705 

 
Your dealer (or your contractor) can only accept the guarantee if the stove has 
been used according to the respective operating instructions. The guarantee 
only applies to the country in which Faber first sold the product and applies only 
to the original buyer, i.e. it is not transferable. On the bill, the day of delivery 
must be indicated.  
 
In the case of improper handling, failure to comply with the operating 
instructions or the use of force, all guarantee claims are void. 
Enamel and paint damage are only covered by the guarantee if they are 
immediately notified in writing to the dealer on delivery of the stove.  
Any transport damage is not covered by the guarantee (this must be claimed 
against the carrier in accordance with the terms of the carrier). 
 
For further information on the guarantee, please see the information and notes 
in the respective chapter of these operating instructions.  
 

IMPORTANT

:  

Damage and defects caused by inadequate maintenance and cleaning and 
through improper interference, repair work or attempts at repair by 
unauthorised persons, and damage and defects resulting from changes or 
disassembly of the stove, where component parts or the flue pipe (chimney, 
stove pipe, etc.) and replaced parts or materials do not correspond to the 
original specifications, are excluded from the guarantee.  

 
4. CONTROL AND FUNCTIONAL ELEMENTS

 

 

4.1 The fire door  

The fire door (viewing window door) must always be closed during heating 
operation and may only be opened to insert wood. The automatic closing of this 
door is effected by a torsional spring (this spring must under no cicumstances 
be put out of operation). See the first design in DIN 18891. The spring is 
subject to wear and must be checked regularly and exchanged as required). 
The lock must be effected manually. To add fuel, slowly open the fire door after 
extinction of the flames in order to avoid the discharge of smoke and flying ash 
into the living area.  
 

4.2 The primary air

  

The stove has a primary air damper for fine air adjustment, this is under the fire 
door.  

Содержание BRANDE 82

Страница 1: ...Assembly and operating instructions for freestanding wood stove models HAAKON BRANDE 82 April 2007 ...

Страница 2: ...d stove Keep this guide close by to allow you to carry out the correct operations at the beginning of the heating period A guarantee from your dealer or your contractor can only be honoured if the attached operating instructions have been respected and you have the original bill In the case of misuse failure to comply with the operating manual or use of force the guarantee is no longer valid Paint...

Страница 3: ...d stove For this reason if you have the intention to seal windows and doors with special sealing you should obtain professional advice Your contact in this case is the chimney sweep plumber heating engineer or your energy supplier These professionals can tell you what must be done 1 3 Chimney The performance of your wood stove also depends on your chimney It can be affected by the cross section of...

Страница 4: ...ty itself otherwise the smoke draught would be affected We recommend the use of a double wall lining here The chimney should have an easily accessible soot door We recommend that the chimney or the pipe is equipped with a damper so that the chimney draught can be regulated on days with strong winds It is not allowed that the damper close the pipe totally There must always be a free area of min 20 ...

Страница 5: ...ber that most components in the stove flue pipe safety window cladding and controls etc become hot during heating and therefore represent a combustion hazard So please use gloves Children should never be left unattended with a burning wood stove Ensure that they never play with the stove controls never use spirits alcohol petrol or other flammable liquids Only use the fuel specified in the owner s...

Страница 6: ...serted 5 If work is being carried out on flammable or explosive materials in the vicinity of the stove the stove must be put out of operation NOTE No liability is accepted for any direct or indirect damage caused by the stove This includes dirtying of the room caused by the decomposition of products from organic dust and whose pyrolysis products appear as a dark line on wallpaper furniture textile...

Страница 7: ...he stove During the combustion process the expansion and contraction of the steel causes slight crackling sounds 3 2 Using the stove in the seasonal transition period During the transitional period spring autumn with an outside temperature above 15 C draught disturbances occur in the chimney Before commissioning of the stove you should therefore always check the chimney at this temperature by mean...

Страница 8: ... with heat resistant paint These heat resistant stove paints do not offer corrosion protection so that rust may occur in unfavorable conditions for example through Wet cleaning near the feet base plate Spilt water from water boilers or pots Installation in damp areas such as a winter garden or through temporary storage in an open building garage Clean the rusted area with fine emery paper and spra...

Страница 9: ...ation of the stove especially if the stove is heated too strongly The plates need to be checked regularly and may need to be replaced The required plates can be obtained from your dealer as a spare part The loosely positioned opposing plates can be easily replaced carefully by oneself NOTE Handle the plates carefully Risk of breakage Glass During proper firing usually a secondary air curtain is de...

Страница 10: ...th the terms of the carrier For further information on the guarantee please see the information and notes in the respective chapter of these operating instructions IMPORTANT Damage and defects caused by inadequate maintenance and cleaning and through improper interference repair work or attempts at repair by unauthorised persons and damage and defects resulting from changes or disassembly of the s...

Страница 11: ...owards the wood It thus necessary to avoid the ash tray becoming overfull because the ashes may negatively affect the access of the primary combustion air When burning wood logs the slide must first be fully opened After ignition of the wood the primary air damper may be closed if necessary ...

Страница 12: ...er because it can lead to draught problems and exiting of smoke into the living area 5 HEATING WITH Haakon Brande 82 5 1 Initial commissioning Before the first operation of the stove remove any transportation supports accessories operating instructions and information sheets from the ash tray or fire box which may have been included IMPORTANT Before commissioning of the unit one must check the cor...

Страница 13: ...irelighters or wood wool in the centre of the fire area then add 0 5 kg of wood chips in layers The grate should always be covered with wood over its entire surface Ignite firing Place ignition material in several places When the ignition material has been ignited everywhere close the fire door Test the stove draught Is the smoke drawn off easily through the chimney If not see the Guide in Chapter...

Страница 14: ...osition the damper in the longitudinal direction of the pipe Primary air closed Move primary air slide across to the closed position according to 4 2 Open fire door Slowly so that no smoke enters the living area Place logs Two to three logs with max 2 kg in weight Lateral direction in the fire area Place wood In only one location Close fire door The replenishment should occur when the flames of th...

Страница 15: ...wide spacing between them and in accordance with the above information at nominal temperatures or light load for the position of the primary air and secondary air slides NOTE On exceeding the maximum amounts there is a risk of overheating which could cause damage to the stove and the danger of a chimney fire IMPORTANT Damage caused by too large quantities of wood or through the use of inappropriat...

Страница 16: ...ng Sect 1 3 and 4 4 The wood burns too quickly The chimney draught is too strong Sect 1 3 and 4 4 The wood is cut too small Sect 3 3 and 5 Controls incorrectly set Sect 5 Smoke comes into the living area during operation The air intake is too low The damper is closed too far The chimney is too small or the chimney cross section is too narrow The flue draught in the stove pipe or chimney are strong...

Страница 17: ...re box width 250 284 mm Weight approx 125 105 kg Space heating capability up to 105 m depending on the thermal insulation of the building Suitable fuels wood logs wood brown coal briquettes Data for chimney dimensioning according to DIN 4705 with respect to a nominal thermal power NTP Flue mass flow with respect to NPT 5 9 7 8 g sek Flue temperature in the pipes 325 302 C Minimum NPT supply pressu...

Страница 18: ...18 Dimensions Haakon ...

Страница 19: ...19 Dimensions Brande 82 ...

Страница 20: ...20 ...

Страница 21: ...21 ...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...24 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: