Faber BELLA 30 Скачать руководство пользователя страница 14

14

USE  AND  CARE  INFORMATION

For Best Results

Start the rangehood several minutes before cooking to develop proper airflow. Allow the rangehood to 

operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.

Button Function

Display

A

Turns the suction motor on and off at speed one.

Displays the set speed

B

Decreases the working speed.

Displays the set speed

C

Increases the working speed.

Displays the set speed

D

Activate intensive speed from any other speed, 

including motor off. This speed is set to operate for 

6 minutes, after which the system returns to the 

speed that was set before. Suitable to deal with 

maximum levels of cooking fumes.

Displays HI and the time remaining once very 

second.

Press and hold the button for approximately 5 

seconds, with all the loads turned off (Motor and 

Lights), to turn the Activated Charcoal Filter alarm 

On and Off.

FC+Punto (2 flashes)–Alarm On.

FC+Punto (1 flash)–Alarm Off.

E

24H function

Turns the suction motor on at speed one and effects 

one 10 minute extraction every hour. 

Displays 24 and the spot at the bottom right flashes 

once every second, while the motor is running.

It is disabled by pressing the button.

When the filters alarm is triggered, the alarm can 

be reset by pressing and holding this button for 

approximately 3 seconds. 

These indications are only visible when the motor 

is turned off.

FF flashes three times.

When the procedure terminates, the indication 

shown previously turns off:

FG 

indicates the need to wash the metal 

grease filters. The alarm is triggered after the Hood 

has been in operation for 100 working hours. 

FC 

indicates the need to change the 

activated charcoal filters, and also to wash the 

metal grease filters. The alarm is triggered after the 

Hood has been in operation for 200 working hours.

F

Delay function 

Activate automatic switch-off with a 30’ delay. 

Suitable to complete elimination of residual odours. 

Can be activated from any position, and is disabled 

by pressing the button or turning the motor off.

Displays the operating speed and the spot at the 

bottom right flashes once a second.

Press and hold the button for approximately 5 

seconds, with all the loads turned off (Motor and 

Lights), to turn the Remote Control On and Off.

IR+Punto (2 flashes)– Remote Control On.

IR+Punto (1 flash)– Remote Control Off.

G

Turns the lighting system on and off at maximum 

intensity.

H

Turns the Courtesy Lighting on and off.

Содержание BELLA 30

Страница 1: ...BELA30SS600 B BELA36SS600 B Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien BELLA 30 36...

Страница 2: ...with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING...

Страница 3: ...and ventilation air Failure to follow venting requirements may result in a fire WARNING Cold Weather installations An additional back draft damper should be installed to minimize backward cold air fl...

Страница 4: ...or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded Failure to follow electrical requirements...

Страница 5: ...5 RANGEHOOD DIMENSIONS Min 24 Min 30 29 1 2 35 1 2...

Страница 6: ...1 8 x 3 8 12d 2 Screws 1 8 x 3 8 Qty Documentation 1 Instruction Manual Available Accessories Parts needed 6 Round Metal ductwork Direct Connect Wiring Box sku number WIREBOX High Ceiling Chimney Kit...

Страница 7: ...e Hood before connecting to the ductwork Only for Ducted Venting Installation Choose your ducting method Non Ducted Recirculation Option Ducted Venting Options Installation Requires purchase of Activa...

Страница 8: ...cket 7 2 1 on the wall as shown about 1 1 8 from the ceiling or upper limit aligning the center notch withtheverticalreferencelineandmarkthewallatthecentersoftheholesinthebracket Place the second brac...

Страница 9: ...l the way to wall leaving 3 16 of the screw heads exposed Use a level to level the hood body by the screws as show Hook the hood body onto the two screws as show I 6x 11 8 Install Roof or Wall Cap pur...

Страница 10: ...nd the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12b 12a N 2x 12d 2 2 2 1 13 Slightly widen the two sides of the the lower chimney hoo...

Страница 11: ...hind the brackets and connect to the Ductless Diverter mak ing sure that they are well seated 14 15 12a Only for the recirculation version connect the hood to the Air outlet Fix the lower Bracket 7 2...

Страница 12: ...Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the pow...

Страница 13: ...widen the two sides of the the lower chimney hood and hook them between the upper section and the wall making sure that they are properly housed Fix the the lower chim ney hood laterally to the hood b...

Страница 14: ...ry second while the motor is running It is disabled by pressing the button When the filters alarm is triggered the alarm can be reset by pressing and holding this button for approximately 3 seconds Th...

Страница 15: ...elyno effectontheefficiencyofthefilteritself Replace takingcaretoensurethatthehandlefacesforwards Replacing Activated Charcoal Filter Itcannotbewashedorregenerated andmustbechangedwhen theFCsymbolonth...

Страница 16: ...16 Wiring Diagram 991 0442 621 H90 308 r1 D002937_00...

Страница 17: ...om accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved...

Страница 18: ...nevoiedesortiesetrouvederri revouspendantquevous teignezlesflammes D apr sleguide KitchenFiresafetyTips publi parlaNFPAaux tats Unis AVERTISSEMENT POURR DUIRELERISQUED INCENDIEOUDECHOC LECTRIQUE n uti...

Страница 19: ...nces en mati re de ventilation pourrait entra ner un incendie AVERTISSEMENT Installation dans les climats froids Le syst me de ventilation doit pr voir un registre antirefoulement suppl mentaire pour...

Страница 20: ...sible dans le circuit neutre ou de mise la terre peut entra ner un choc lectrique Consultez un lectricien qualifi si vous n tes pas certain de la mise la terre de la hotte Le non respect des exigences...

Страница 21: ...21 DIMENSIONS DE LA HOTTE Min 24 Min 30 29 1 2 35 1 2...

Страница 22: ...x3 8 Qt Documentation 1 Moded emploi Accessoires disponibles Pi ces requises Conduitm tallique6 circulaire Bo tier de connexion directe No d article WIREBOX Trousse de chemin e pour plafonds hauts Con...

Страница 23: ...der aux conduits Pour installation avec ventilation canalis e uniquement Choisissez la m thode de canalisation Sans canalisation Option de recirculation Options d installation avec ventilation canalis...

Страница 24: ...comme illustr environ 1 1 8 du plafond ou de la limite sup rieure en alignant le centre encoche avec la ligne de r f rence verticale Marquez l emplacement du centre des trous du support sur le mur Pl...

Страница 25: ...e illustr Nelesvissezpascompl tementaumur mais laissez libre 3 16 de la t te des vis Utilisezunniveaupourvousassurerquelahotteest niveau puisvissez fondlesdeuxvis Engagezleb tidelahottesurlesviscomme...

Страница 26: ...hemin e sup rieureet engagez lesder ri relesbrides 7 2 1 envous assurantqu ils sontsolidement ancr s Fixezlesc t sauxbrides l aidedes4vis12b cartezl g rementlesdeux c t sdelasectioninf rieure delachem...

Страница 27: ...e 7 2 1 inf rieure l aide de deux vis 12a fournies comme illustr Fixez le d flecteur de recyclage l aide de deux vis 12a fournies comme illustr cartez l g rement les deux c t s de la chemin e sup rieu...

Страница 28: ...prenez pas parfaitement les instructions de mise la terre ou si vous avez des doutes quant la mise la terre de l appareil N utilisez pas de rallonge Si le cordon d alimentation est trop court demandez...

Страница 29: ...tion inf rieure de la chemin e de hotte et assemblez les entre la section sup rieure et le mur en vous assur ant qu ils sont correcte ment install s Fixez la section inf rieure de la chemin e de hotte...

Страница 30: ...0 minutes par heure Affiche 24 et le point en bas droite clignote une fois par seconde alors que le moteur est en fonction Appuyer sur la touche pour d brancher L alarme filtres tant activ e appuyer s...

Страница 31: ...decedernier Lesremonterenveillant cequelapoign esoittoujoursvers lapartievisibleexterne Replacing Activated Charcoal Filter Nonlavableetnonr g n rable ildoit treremplac l affichage deFCouaumoinstousle...

Страница 32: ...32 Sch ma de c blage 991 0442 621 H90 308 r1 D002937_00...

Страница 33: ...es d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confo...

Страница 34: ......

Страница 35: ......

Страница 36: ...991 0454 810_05 180626 D002767_04...

Отзывы: