Faber 630000815 Скачать руководство пользователя страница 2

upper

chimney

cover

ductless

lower

chimney

cover

canopy

cabinet base

x = distance from hood to cooktop

(varies depending on installation)

min  -  24”,  suggested  max  -  30”

also consult cooktop

manufacturer's recommendation

1" min
7" max

31"

36”

x

min & max ceiling height examples

x = 30"

min

8'

 4 5/8"

max

8' 

10 5/8"

x = 28"

min

8'

 2 5/8"

max

8' 

8 5/8"

x = 26"

min

8' 

5/8"

max

8' 

6 5/8"

x = 24"

min

7' 

10 5/8"

max

8' 

4 5/8"

20"

5/8”

3

 3/4”

upper

chimney

cover

lower

chimney

cover

canopy

cabinet base

x = distance from hood to cooktop

(varies depending on installation)

min  -  24”,  suggested  max  -  30”

also consult cooktop

manufacturer's recommendation

  3 

3/8”

  min

14 

3/8”

 max

23 

5/8”

5/8”

36”

x

min & max ceiling height examples

x = 30"

min

7' 

11 5/8"

max

8' 

10 5/8"

x = 28"

min

7' 

9 5/8"

max

8' 

8 5/8"

x = 26"

min

7' 

7 5/8"

max

8' 

6 5/8"

x = 24"

min

7' 

5 5/8"

max

8' 

4 5/8"

Rev.06/08

WARNING!

  Product specifications are subject to change without notification.  Consult the installation instructions 

before you begin installing this rangehood.

Pre-Planning Your Ductwork

Ductless Installations*

For installations where ductwork is im

-

possible or highly impractical, a ductless 

conversion kit is available.  A charcoal 

filter, which attaches under the blower 

assembly, absorbs smoke and odors.  A 

ductless diverter assembly directs the air 

out to a lower chimney with a vent grate 

cut into the back.

Make your ductrun as straight and short as possible.  The ductrun should 

not exceed 35 equivalent feet if ducted with the required minimum of 6” 

round duct.  Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat 
elbows as 12 feet.

For best results, use no more than three 90° elbows. Make sure that 
there is a minimum of 24” of straight duct between elbows if more 
than one is used. Do not install two elbows together. If you must 
elbow right away, do it as far away from the hood’s exhaust opening 
as possible.

Ducted

* it is highly recommended that professional style cooking always be vented to the outside.

Ductless

Dimensional Diagrams

Pre-Planning Your Installation

 - 

Important: Consult the installation instructions before you begin installing this rangehood.

Note: The Ductless 

Vent Grate exhausts 

toward the rear of the 

chimney.

Ducted

Ductless

The ducted Axia Isola chimney can be adjusted for ceilings between 7’ 5 5/ 8” and 8’ 10 5/ 8” depending on the distance between the bottom of the hood and the 
cooktop (distance x in above DUCTED diagram).  The ductless Axia Isola chimney can be adjusted for ceilings between 7’ 10 5/ 8” and 8’ 10 5/ 8” depending on the 
distance between the bottom of the hood and the cooktop (distance x in above DUCTLESS diagram).