background image

Fabco Power 

 

 

Instruction Manual 

• Page 3   

 
 

RECOMMENDATIONS              

MODEL: HYDRO 400X-6 

 
 
 

 

 

 

HIGH PRESSURE LINE ........................ ½ inch 

 
 

LOW PRESSURE LINE .......................... ¾ inch 

 
 

FLOW RATE .......................................... 6 to 25 GPM 

 

 

(6 GPM IDEAL) 

 
 

FOR BEST RESULTS KEEP HYDRAULIC OIL   

 

TEMPERATURE BETWEEN 80°F AND 120°F.   

 

DO NOT EXCEED 175°F. 

 
 

AN OIL COOLER IS RECOMMENDED. 

 
 

MAXIMUM BACK PRESSURE ............. 150 PSI 

 
 

WILL OPERATE ON ANY 2500 PSI OPEN CIRCUIT   

 

OR CLOSED LOOP SYSTEMS. 

 
 

RECOMMEND FILTER  ........................ 10m 

 
 

RECOMMEND HYDRAULIC OIL  ....... DEXTRON III A.T.F. 

 
 
 
 

INSTALLATION TIPS   

 

Excessive pressure in your return line will damage the hydraulic motor seal.  High back pressure can be caused by 
“spikes” sent back through the return from other equipment on a common return line.  Another potential problem 
can develop if several pieces of equipment are connected to one “common” return line causing a high back 
pressure (150 PSI is the maximum).  We recommend you run the return line from the generator back to the 
cooling tank with a separate line. 

 

You can either run the 3/4 inch return line back to the tank or leave the 3/4 inch line connected to a common 
return and run a separate 3/8 inch line from the case drain (located at the bottom of the hydraulic motor) directly 
back to the tank.  Either way you completely eliminate any problem of excessive return line pressure damaging 
your hydraulic motor. 
 
 
 
 

Содержание Hydro 400X-6

Страница 1: ...e Power Instruction Manual for Model HYDRO 400X 6 Hydraulic Generator Manufacturing of Vehicle Mounted Generators Hydraulic Generators P O Box 582 Chester NY 10918 845 469 9151 Fax 845 469 7871 Web Si...

Страница 2: ...OTOR STARTING 300 SURGE VOLTAGE REGULATOR INHERENT OUTPUT 4000 WATTS CONTINUOUS 4500 WATTS PEAK AT 100 F OIL TEMPERATURE HYDRAULIC MOTOR GEAR TYPE WITH BUILT IN FLOW CONTROL FLOW CONTROL PRESSURE COMP...

Страница 3: ...h back pressure can be caused by spikes sent back through the return from other equipment on a common return line Another potential problem can develop if several pieces of equipment are connected to...

Страница 4: ...cal load on the generator By using this setting you will have approximately 60HZ cycles or 3600 RPM when you are running at full rated load One way this can be accomplished is by using a Photo Tachome...

Страница 5: ...what the load Drive motor speed control systems generally have a small drop in speed between no load and loaded conditions We therefore recommend setting no load speed 3 4 above nominal speed CHECKING...

Страница 6: ...GENERATOR FRAME USE GREEN WIRE FOR GROUND IF USING GFCI OUTLETS 120 TERMINAL BLOCK TERMINAL BLOCK 30 AMP OVERLOAD SELF RE SETTING 120 240 VOLT OPERATION 25 AMP OVERLOAD SELF RE SETTING GROUND SCREW O...

Страница 7: ...20 572615 Pump Mount 21 572066 Coupling 24mm 22 572067 Spider 23 572068 Coupling 24 572324 Motor w Flow Control 25 572128 Rails 26 572154 Mounts 27 572206 Flow Control Cartridge 6 GPM 28 572261 Stud C...

Страница 8: ...lace LOW NO LOAD VOLTAGE 1 Speed too low 2 Faulty rotary diodes 3 Breakdown in windings 4 Capacitor with high capacity 1 Check and adjust RPM s 2 Check and replace 3 Check winding resistance as per ta...

Страница 9: ...INE FILTER 8 OIL COOLER 9 HYDRAULIC FLUID RESERVOIR Some units may be equipped with integral priority flow control refer to specific model number External case drain line may be required on some units...

Страница 10: ...Fabco Power Instruction Manual Page 10 BRUSHLESS GENERATOR WIRING...

Страница 11: ...Fabco Power Instruction Manual Page 11 HYDRAULIC MOTOR HOSE HOOK UP Fabco Power...

Страница 12: ...Fabco Power Instruction Manual Page 12...

Страница 13: ...Fabco Power Instruction Manual Page 13...

Отзывы: