XTR B
5
532109 - Rev.A
ON
1 2 3 4 5
Dip 5 = OFF
ON
1 2 3 4 5
Dip 5 = ON
1 = ON ; 0 = OFF
1
1CH mode
3.1 CONNECTING TO THE BOARD WITH
BUS 2EASY
CONFIGURING THE DIP-SWITCHES
Position the dip-switches (
1
or
2
) in order
to specify:
-
1CH or 2CH mode of operation (Dip-switch 5)
-
the commands that the XTR B transmits to the
board (Dip-switches 1-2-3-4)
!
For each control device connected to the
BUS 2easy line, position the dip-switches so
that a command is used only on one device.
L
L
In order to add an XTR B to an existing sys-
tem you must know which commands are
already used on the other BUS 2easy devices
that are present. See the instructions for
the devices that are already installed in
2
2CH mode
order to identify which commands are already
used. For future reference, you can make a
note of the IDs of the installed devices in
the table at the end of this manual. Any
BUS 2easy photocells or BUS 2easy safety
edges do not interfere with the control de-
vices. Their dip-switches can be ignored.
Dip-switch
1 2 3 4
command
0 0 0 0
Open A_1
0 0 0 1
Open A_2
0 0 1 0
Open A_3
0 0 1 1
Open A_4
0 1 0 0
Open A_5
0 1 0 1
Stop
0 1 1 0
Stop NC*_1
0 1 1 1
Stop NC*_2
1 0 0 0
Close
1 0 0 1
Open B_1
1 0 1 0
Open B_2
1 0 1 1
Open B_3
1 1 0 0
Open B_4
1 1 0 1
Open B_5
1 1 1 0
not used
1 1 1 1
not used
Dip-switch
1 2 3 4
Command 1
Command 2
0 0 0 0
Open A_1
Open B_1
0 0 0 1
Open A_1
Open B_2
0 0 1 0
Open A_1
Stop
0 0 1 1
Open A_1
Close
0 1 0 0
Open A_2
Open B_1
0 1 0 1
Open A_2
Open B_2
0 1 1 0
Open A_2
Stop
0 1 1 1
Open A_2
Close
1 0 0 0
Open A_3
Open B_3
1 0 0 1
Open A_3
Open B_4
1 0 1 0
Open A_3
StopNC*_1
1 0 1 1
Open A_3
Close
1 1 0 0
Open A_4
Open B_3
1 1 0 1
Open A_4
Open B_4
1 1 1 0
Open A_4
StopNC*_2
1 1 1 1
Open A_4
Close
* Stop NC, also generates a Stop when the XTR B is disconnected.
Содержание XTR B
Страница 1: ...XTR B EN ...
Страница 7: ...XTR B 05 532109 Rev A 4 5 5 click XTRBINOX XTRB ...