LED-SIGNALS
The ORANGE LED
fl ashes 1 x
every 3 seconds.
Bad adjustment
The ORANGE LED is
on permanently.
The ORANGE LED
fl ashes quickly.
The RED or GREEN
LED is ON sporadicly.
Check if the DIP-switch 4 is ON (uncovered zone).
Launch a calibration.
Send the sensor back for a technical check-up.
Corfi rm the DIP-switch setting:
long push on the push button.
Cut and restore power supply.
If orange LED fl ashes again, replace sensor.
The sensor does not
react, but a calibration
can be launched.
Chech wiring.
- Door control with test:
Connect RED and BLUE wires to test output.
- Door control without test:
Connect RED to 0 V and BLUE to +12 V - 30 V DC.
The ORANGE LED
fl ashes 2 x
every 3 seconds.
The ORANGE LED
fl ashes 3 x
every 3 seconds.
The ORANGE LED
fl ashes 4 x
every 3 seconds.
The ORANGE LED
fl ashes 5 x
every 3 seconds.
Check power supply (tension, capacity).
Reduce the cable length or change cable.
Check wiring between modules.
Launch a module count: long push on push button
of MASTER.
Launch a new calibration.
Step out of the detection fi eld.
Change angle of spots.
Switch off background (DIP 3: OFF).
Launch a new calibration.
Power supply is out of limit.
The sensor signals an
internal fault.
Bad adjustment of the
uncovered zone.
The monitoring is activated,
but the test input is not
powered.
Communication error
between modules.
The sensor receives
not enough IR-energy.
The sensor receives too
much IR-energy.
The sensor encounters
a memory problem.
DIP-switch setting
awaiting confi rmation.
The RED or
GREEN LED is ON
permanently.
The ORANGE LED
fl ickers.
The sensor is disturbed by
lamps or another sensor.
Select a different frequecy for each module (DIP 2).
Launch a new calibration.
Calibration error
Check mounting height.
Change position of calibration screw.
Launch a new calibration.
Check if the DIP-switch 4 is ON (uncovered zone).
Launch a calibration.
BEA hereby declares that the FAAC XPB34-1/70-1/90-1/90-2 ON is in conformity with the basic requirements and the other
relevant provisions of the directives 2004/108/EC and 2006/42/EC.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, May 2013
Pierre Gardier, Authorized representative
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable
national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC.
Only trained and qualifi ed personnel may install and setup the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
XPB34-1/70-1 ON
XPB90-1/90-2 ON
1
2
3
4
5
6
7
8
9
10
11
E
R
L
A
U
B
T
Z
E
R
T I
F I
Z I E R U N G
N
A
C
H
DIN 1
865
0
E
N
A
B L
E S
A C C
O
R
D
A
N
C
E
W
I
T
H
TECHNICAL SPECIFICATIONS
1. profi le
2. supporting
clip
3. main
connector
4. DIP-switch
5. calibration
screw
6. receiver
DESCRIPTION
ENGLISH
Safety sensors
for automatic swing doors
7. end
cap
8.
clip with angle adjustment screw
9. transmitter
(TX)
10. push
button
11. front
face
active infrared with background suppression
400 mm (W) x 70 mm (D) (at 2 m mounting height; 4 spots active)
1.1 m to 3 m (according to fl oor refl ectivity)
64 ms (typ)
infi nite
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
(to be operated from SELV compatible power supplies only)
110 mA @ 24 V AC/ 70 mA @ 24 V DC; 190 mA @ 12 V AC/ 145 mA @ 12 V DC (MASTER)
85 mA @ 24 V AC/ 60 mA @ 24 V DC; 180 mA @ 12 V AC/ 113 mA @ 12 V DC (other modules)
2 relays (free of potential contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 60 VA (AC)
1 optocoupler (free of potential contact)
30 V
high: >10 V DC; low: <1 V DC
4 (up to 6 if 24 V DC)
min. 5% at IR-wavelength of 850 nm
IP53
-25 °C to +55 °C; 0-95% relative humidity, non condensing
5 years
EMC 2004/108/EC; MD 2006/42/EC; EN 12978
EN ISO 13849-1:2008 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Technology:
Detection fi eld:
Mounting height:
Reaction time:
Max. presence time:
Supply voltage:
Max current consumption:
Output:
Max. contact voltage
Max. contact current
Max. switching power
Input:
Max. contact voltage:
Voltage threshold:
Max. number of modules:
Refl ectivity:
Degree of protection:
Temperature range:
Expected lifetime:
Norm conformity:
Other use of the device is outside the permitted purpose
and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect
installations or inappropriate adjustments of the sensor.
For pr
oduct version 0100 and mor
e
Please keep for further use
Designed for colour printing
Specifi cations are subject to changes without prior notice.
All values measured in optimal conditions.