Setting the radar sensitivity by push button

 

 

 
 
 

 

 

 

  Each 

short press

 on the right button increases the size 

of the radar sensing field. 

 

 

 

 

 

 

 

 

 

 

 

  Each 

short press

 on the left button decreases the size of 

the radar sensing field. 

 

 

 
 

 

 

 

IR presence sensing field : width

 

 

2m

35

cm

 

 

1m

35

c

m

 

 

 

Make sure to introduce the front  

prism into the foreseen slides  

in front of the lenses!

 

 

 

 

 

 

 Above 3 m mounting height, use the narrow prism! 

 
 

 

 

 

IR presence sensing field: depth (negative angle available)

 

 

 

+4°

-4°

 

 

The pin shown here above indicates 
the angle adjusted. 

 

To approach the curtain to the door, turn the 
screw clockwise. To tilt the curtain out, turn the 
screw counterclockwise. 

 

 

 

 

 

 

 

 

 

Å

 

Keep a 

minimum distance of 5cm 

between the door and the curtain.

 

 
 
 

 

 

Launching a setup

 

 

 
 
 
 

Short setup  

 

  Cut and restore power. 

Recommended after adjustments by push buttons.

 

  The sensor takes a new reference 

picture. 

 

 

 

 

 

 

 

Assisted setup 

 

  Press and hold the right push button until the LED flashes 

RED-GREEN.  
Recommended after first installation or mechanical 
adjustments of the IR-module. 

  The sensor performs a door opening 

and closing cycle to check the influence 
of the door leaves on the safety curtain. 

LED display during setup 

 
 

 

 

 

RED- 

GREEN 

LED

 

Setup-process active: the sensor learns its environment. After finishing the setup process, the sensor shows the following behavior: 

 

NO LED 

The sensor successfully finished its setup. 

 

 

 

 

RED LED flashing quickly 

The sensor ‘sees’ the door movement and can not finish its setup (see troubleshooting). 

 

 

 

 

ORANGE LED continuously on  The sensor encounters signal saturation (see troubleshooting). 

 

 
 

2 curtains of 24 overlapping spots

(no holes between spots)

2 curtains of 12 overlapping spots 

(no holes between spots)

Содержание XMA

Страница 1: ...on Tip LED display during normal function GREEN LED Motion detection RED LED Presence detection ORANGE LED See chapter 4 Troubleshooting 1 Tips Avoid touching electronical parts Avoid touching optical parts Make sure the operator cover is fixed properly and electrically earthed Avoid vibrations Do not cover the sensor Avoid moving objects in proximity to the sensor Avoid discharge lamps and fluore...

Страница 2: ...ensor 3 Wiring the sensor To ensure good water protection place the cable as shown above 4 Radar motion sensing field width Sensitivity 9 Sensitivity 9 Touching the antenna patches while exchanging will not cause any damage 5 Radar motion sensing field depth 15 30 45 30 45 15 0 2 1 0 1 2 1 2 3 1 2 3 15 30 45 Sensitivity 9 2 1 0 1 2 1 2 3 1 2 3 15 45 30 4 4 Sensitivity 9 ...

Страница 3: ...rt setup Cut and restore power Recommended after adjustments by push buttons The sensor takes a new reference picture Assisted setup Press and hold the right push button until the LED flashes RED GREEN Recommended after first installation or mechanical adjustments of the IR module The sensor performs a door opening and closing cycle to check the influence of the door leaves on the safety curtain L...

Страница 4: ...ight 250 g Housing material ABS LURAN S Minimum length of cable 2 6 m MOTION SENSOR PRESENCE SENSOR Detection mode Motion Bidirectional Minimum detection speed 5 cm s measured in sensor axis Presence Typical response time 128ms max 500 ms Technology Microwave and microprocessor Transmitter frequency 24 175 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 mW cm Focused active ...