1257014-GB_v1.1 

STD-1EU / STD-2EU 

 

2

CONNECTION 

1  

230V

 

2  

230V

 

3  

Motor 1 

4  

Motor 1 

5  

Common motor 1 

6  

Motor 2 (STANDARD/2-EU version) 

7  

Motor 2 (STANDARD/2-EU version) 

8  

Common motor 2 (STANDARD/2-EU version) 

9  

Garage light contact (LUZ GAR.) 

10  

Garage light contact (LUZ GAR.) 

11  

Flash light contact (DESTELLO) 

12  

Flash light contact (DESTELLO) 

13  

Electro-lock outlet (12V

=

 / 1A) 

14  

Electro-lock outlet (12V

=

 / 1A) 

15  

Security device outlet (24V

 / 0.75A) 

16  

24V

 common outlet  

17  

24V

  autotest outlet (TEST SEC.) 

18  

Common securities 

19  

Security Close contact (NC) 

20  

Security Open contact (NC) 

21  

Security Close edge (resistive contact 8k2) 

22  

Security Open edge (resistive contact 8k2) 

23  

Common ends of run 

24  

End of run Close motor 1 

25  

End of run Open motor 1 

26  

End of run Close motor 2 (STANDARD/2-EU version) 

27  

End of run Open motor 2 (STANDARD/2-EU version) 

28  

Common buttons 

29  

Pedestrian button (NO) 

30  

Start button (NO) 

31  

Close button (NO) 

32  

Common buttons 

33  

Stop button (NC) 

34  

Start button (NO) 

 
 

INSTALLATION 

Any handling of the panel for installation must be carried out with the power supply disconnected. 

 

FITTING THE CASING 

• Parts: front casing and container box. 

• Unscrew the securing points. Insert the cables through the lower holes. 

 

IMPORTANT CONSIDERATIONS FOR START-UP 

If the door does not open when the button is first pushed, invert the motor cables. 

Where inversions are made, the panel adds time to ensure the door closes. 

Any optional cards must be connected to the panel with the power supply disconnected. 

 
 

OPERATING 

Start (ALT): Contact normally open to open and close. First time the button is pressed, it opens; the 
second time (if it has not reached the end of the run), it stops and the third time it closes. 

 

Содержание STD-2EU

Страница 1: ...ICS Panel supply 230V ac Power 3 4CV Optional cards Pluggable receiver card 2 channels 433 92 868 35 MHz and traffic light card Security device output 24V ac 0 75A and autotest Electro lock outlet 12V...

Страница 2: ...Close motor 2 STANDARD 2 EU version 27 End of run Open motor 2 STANDARD 2 EU version 28 Common buttons 29 Pedestrian button NO 30 Start button NO 31 Close button NO 32 Common buttons 33 Stop button N...

Страница 3: ...V Flash light contact DESTELLO Voltage free maintained contact to activate a Flash light max 250V 12A Electro lock ELECTRO 12V output timed for 2 seconds to activate an electric latch of a maximum of...

Страница 4: ...ling Minimum Maximum Motor operating 3s 120s Wait for automatic close 3s 120s Gap between motors 0s 120s LIGHT INDICATORS Function Indicates Default status POWER Alimentation Normally on SEG Security...

Страница 5: ...ps if the end of run has not been reached and the automatic standby timer begins When pressed for the fifth time the automatic standby timer stops and motor 2 is started to close When pressed for the...

Страница 6: ...g the panel check that the door is in good mechanical condition correctly balanced and that it opens and closes correctly Install the manual unlocking device at a height lower than 1 8m Install any pe...

Страница 7: ...ls on how to use the manual unlocking device must be provided by the manufacturer or the device installer Examine the installation frequently especially the cables springs and supports to detect signs...

Отзывы: