20
3.3 WALL SET-UP
3.3.1. Foundation plate
The diagram below indicates the values of the foundation plate.
c
b
a
d
i
Figure 7 -
Foundation plate
Ref. Dimension
a
400 mm
b
360 mm
c
Ø 200 mm
d
Ø 13 mm
e
5 mm
f
600 mm
g
400 mm
h
500 mm
i
220 mm
3.3.2. Installing the plate
e
f
g
h
Figure 8 -
Plate positioning
Pitch Action
1
Assemble the foundation plate.
2
Perform a foundation plinth.
3
Wall up the foundation plate by set-
ting up two or more sheaths for the
data and electric cables to be passed.
4
Make sure the plate is perfectly hori-
zontal with a spirit level. Wait for the
cement to set.