- Power supply: battery pack with six LR20 alkaline
batteries sealed in series
- Consumption in surveillance status: 300 µA max.
- Average consumption in alarm status: < 1.15 A
- Average consumption in emission status: < 50 mA
- Time range: 30 months under normal use
conditions
- Acoustic power at 1m: 109 dB +/- 2 dB
- Modulation: C 48-465 standard
- Self-protection: opening and housebreaking
- Signals:
alarm: 90 secs.
discharged batteries: indicated by a series of
acoustic signals and by sending radio information
to the control unit
- Control unit / siren radio range:
free field: from 200 to 300 m according to
environment
indoor: according to environment
- Radio communication: two-way
- Radio frequencies: 434 and 868 MHz band
- Enclosure: ABS-PC
- Operating temperature: -25°C / +70°C
- Dimensions: 277 x 188 x 100 mm
- Weight: 2.75 kg (including battery pack)
TEST
- Press the control unit's
“Test”
push-button (green).
The siren will sound for 1.5 seconds to confirm the
test.
Every pressure on the push-button will re-enable the
test.
TECHNICAL
SPECIFICATIONS
The siren must be powered and recognised by
the control unit (learning).
The control unit must be in MAINTENANCE
PROGRAM mode (battery compartment open).
- To return to normal operation: close al the
system's elements (control unit last of all).
Another way of running a siren test:
- Press the “ON” key on the remote control for more
than five seconds, or enter programming on the
control keypad (after inputting the access code)
and select the “Warning Signal Test” menu.
AP
EFF
TEST
Passage open signal
Peripheral units fault
/Telephone line fault
Discharged batteries
Run the system general test, consulting the control
unit instructions.
If activated, the siren is sounded for
90 secs.
To stop the siren sound:
- Press the “OFF” key of the remote control, or
disable the alarm from the control keyboard.
Important:
the siren measures the outdoor
temperature. If there are several sirens in the same
system, the “C5” component of
the additional sirens must be
cut out so that the control
keypad carries out a single
temperature measurement.
- Close the siren door and fasten the screws
The siren is ready for
operation
5
7
6
Note:
the outdoor siren signals the enabling and
disabling of surveillance,
emitting respectively one and
two short beeps. This option
can be disabled by cutting out
component C7.
C5 C6 C7 C8
C5 C6 C7 C8
C5 C6 C7 C8
C5 C6 C7 C8
C5 C6 C7 C8
C5 C6 C7 C8
C5 C6 C7 C8
Содержание HSE
Страница 1: ...Installation and use instructions HSE HSL Outdoor radio siren ...
Страница 5: ...Drilling template detach this ...
Страница 8: ...Drilling template detach this ...
Страница 11: ...7 NOTES ...