25
Complete list of parameters
The table below show the complete list of features.
Programming messages below must begin
with 9999# (assuming 9999 is still the programming passcode)…
Changing pass codes
9999
#
01
????
#
Change
programming password
9999
9999
#
02
????
#
Change access control password (SMS control of relays, or
non-stored numbers can call intercom & enter code to
activate output 1).
1234
9999
#
03
????
#
Change monitoring mode password (user can call the
intercom, enter this pass code to listen in and speak)
5555
Dial out numbers
9999
#
1
XY????
#
Store dialling out numbers. (X = button number 1-9 & 0 for
button 10) (Y = number dialled 1-4) (???? = phone number)
N/A
9999
#
1
XY*
#
Delete a dial out number. (X = button number) (Y = number
position 1-4)
N/A
Volume controls
9999
#
3
?
#
Speaker volume. Where ? = 1-9. 1 = lowest, 9 = highest.
5
9999
#
4
?
#
Microphone volume. Where ? = 1-9. 1 = lowest, 9 =
highest.
5
Timings
Relay Times
Relay default trigger times are 1 second. Use this feature
to change a relay for a longer time perhaps for a
magnetic door lock or to make one relay a momentary
relay and the other a 1 hour relay for example.
SMS string for relay 1:
9999
#
50
XXXX
# (X=time in seconds, 1-9999)
SMS string for relay 2:
9999
#
51
XXXX
# (X=time in seconds, 1-9999)
Enter time in seconds (1-9999)