Estate Slide E-SL 1200
Logic Summaries and Flow Charts
Logic A
-
Logic A (automatic) is the most common setting. It automatically closes the gate depending on the set pause
time. This logic must be used in conjunction with the accessories: Free Exit Sensor and Gate Timer.
Gate Status
Result of Terminal 1
Activation
Result of Terminal 2
Activation
Result of Terminal 4
Interruption
Result of Terminal 5
Interruption
Closed
Opens leaf and re
-
closes after pause time
No effect
Open and in
pause before
re
-
closing
Re
-
loads pause time
No effect
Re
-
loads pause time
Closing
Re
-
opens leaf
No effect
Stops motions and revers-
es direction after interrup-
tion
Opening
No effect
Reverses direction of motion
No effect
Stopped in
mid
-
cycle
Closes the leaf
No effect
Logic S
-
Logic S (safety) is designed for higher control and accelerated levels of safety. By triggering an opening de-
vice (i.e. push button, transmitter) the gate reverses directions preventing foreseeable accidents.
Gate Status
Result of Terminal 1
Activation
Result of Terminal 2
Activation
Result of Terminal 4
Interruption
Result of Terminal 5
Interruption
Closed
Opens leaf and re
-
closes after pause time
No effect
Open and in
pause before
re
-
closing
Re
-
closes the leaf
No effect
Closes after 5 seconds
Closing
Re
-
opens the leaf
No effect
Reverses direction of
motion
Opening
Re
-
closes the leaf
Reverses direction of motion
No effect
Stopped in
mid
-
cycle
Closes the leaf
No effect
13.1