3
ENGLISH
3 TECHNICAL SPECIFICATIONS
Power supply voltage
230Vac (+6% -0%) - 50Hz
Absorbed power
20W
Motor max. load
50W x 2
Accessories max. current
(+24V)
00 mA
BUS Accessories max.current
400 mA
Operating ambient tempera-
ture
-20°C - +55°C
Fuses
F = self-resetting; F2 = T2A-
250V
Function logics
EP, AP
Work time (time-out)
minute (fixed)
Pause time
Varies according to learning
(max. 0 min.)
Terminal board inputs
Open A, Open B, Stop, BUS
(I/O)
Connector inputs
Power supply, battery
module XF 433 or XF 868
Terminal board outputs
Motors, flashing lamp, power
supply to accessories,
electric lock, service light
contact (90 sec fixed)
Programmable functions
Logic (AP, EP), Speed (high
3°/sec and low 0°/sec)
Learning functions
Pause time, leaf 2 delay at
closing
Integrated radio channels
type
DS, SLH (max 250 channels)
LC (max 250 channels - FOR
SOME MARKETS ONLY)
J
POWER SUPPLY connector
J2
SERVICE LIGHT command terminal-board
J3
FLASHING LAMP terminal-board
J4
ELECTRIC LOCK terminal-board
J5
COMMANDS terminal-board
J7
MOTOR terminal-board
J8
MOTOR 2 terminal-board
J9
Rapid connection for XF MODULE
J0
BUS terminal-board
J
BATTERY connector
SW
SET UP push-button
SW2
SPEED push-button
SW3
LOGIC push-button
DS
Programming Dip-switch
F
Accessories protective fuse
F2
Fuses protecting transformers and motors
LED
Signalling LEDs
3.1 DESCRIPTION OF COMPONENTS
Terminal and/or
terminal-board
Description Device connected
J5
+24V
Power supply for
accessories
2
GND
Negative
3
STOP
Device with NC
contact which causes
the automated
system to shut down
4
OPEN B
Device with N.O
contact (see chap.
FUNCTION LOGICS)
5
OPEN A
J0
RED terminal
BUS
Safety devices with
BUS technology
J2
GREY terminal
SERVICE
LIGHT
Service Light control
output (connect a
relay coil at 24Vdc-
00mA max)
J3
ORANGE terminal
LAMP
Flashing lamp 24Vdc
- 5W
J4
BLUE terminal
LOCK
Electric lock 2Vac or
24 Vdc (to be installed
on leaf )
J7
MOT
Motor (leaf )
J8
MOT2
Motor 2 (leaf 2)
3.2 DESCRIPTION OF TERMINAL-BOARDS
4 PROGRAMMING THE LOGIC
The function logic can be selected at any time by pressing
push-button SW3.
The selected logic is then displayed on LED LD7:
LED on = AUTOMATIC STEPPED logic (AP)
LED off = SEMIAUTOMATIC STEPPED logic (EP)
5 PROGRAMMING THE SPEED
The function logic can be adjusted at any time by pressing
push-button SW2.
The selected logic is then displayed on LED LD8:
LED on = HIGH speed (3 °/sec)
LED off = LOW speed (0 °/sec)
Leaf 1 means the leaf which opens first during
the opening operation.
The service light control is active during the
entire gate opening or closing movement and
for the successive 90 seconds.
Содержание E391
Страница 1: ...E391...