background image

E145

E145

Содержание E145

Страница 1: ...E145 E145...

Страница 2: ...remote Programmer conformstotheessentialsafetyrequirementsofthefollowingEECdirectives 2006 95 EC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Directive Additional note this product...

Страница 3: ...ollowing instructions Incorrect installation or incorrect use of the product could cause serious harm to people 2 Carefullyreadtheinstructionsbeforebeginning to install the product 3 Donotleavepacking...

Страница 4: ...NECTOR 14 4 8 J14 Decoder Minidec RP RAPID CONNECTOR 14 4 9 M1A X COM MODULe RAPID CONNECTOR 14 4 10 traditional photocells 15 5 PROGRAMMING 18 5 1 Basic PROGRAMMING functions 19 5 2 Advanced PROGRAMM...

Страница 5: ...Programmable on 50 levels Connector inputs Decoder Minidec RP X COM XF433 868 Module USB A USB B Terminal board inputs Mains power supply from 90 to 260V Inputs from IN1 to IN5 Limit switch BUS 2EASY...

Страница 6: ...L2 DL3 DL4 ENGLISH 3 BOARD LAYOUT 2 PREPARING FOR INSTALLATION For safety reasons it is important for people to carefully follow all the warnings and instructions contained in this manual Incorrect in...

Страница 7: ...4 BUSMON BUS 2EASY diagnostic signalling LED DL15 Device signalling LED to BUS 2EASYACTIVE DL16 Microprocessor power presence LED DL17 24V Accessories power supply presence LED J1 90V a 260V Power sup...

Страница 8: ...c switch has been in stalled N Power Supply Connection from 90 V to 260 V Neutral L Power Supply Connection from 90 V to 260 V Line Motor for SINGLE LEAF or FIRSTLEAFwhenopening closes for the second...

Страница 9: ...ore than one STOP device connect the N C contacts in series see related Fig If stop devices are NOT connected jumper the terminals STOP and GND 12 IN4 FSW CL contact N C closing safety Connect a photo...

Страница 10: ...whatever position the stopped leaf is in When BUS 2EASY encoder is enabled the electric lock is operated only before opening the closed leaf 22 LOCK 2 Electric lock 12 V or 24 V operated 2 sec before...

Страница 11: ...ding on their position and operation mode Photocells during closing trip only during the closing of the automated system suitable for protecting the closing area from risk of impact Photocells during...

Страница 12: ...lable by programming via a PC MAC see dedicated instructions Dip1 Dip2 Dip3 Dip4 TYPE OF PHOTOCELLS OFF OFF OFF OFF OPENING max 6 pairs OFF OFF OFF ON OFF OFF ON OFF OFF OFF ON ON OFF ON ON OFF OFF ON...

Страница 13: ...LEDs located on the body of each encoder LEAF 1 opens first and closes last 1 LED on On leaf 1 check that with the motor stopped LEDs DL1 and DL2 are on On leaf 2 check that with the motor stopped LED...

Страница 14: ...MODULE RAPID CONNECTOR Plug in rapid connector dedicated to OMNIDEC 2 channel decoding module ALWAYS cut off power to the board BE FORE inserting removing the module 4 8 J14 DECODER MINIDEC RP RAPID...

Страница 15: ...otecting the opening area from risk of impact Photocells for opening closing trip during both the opening and closing suitable for protecting the entire movement area from risk of impact Pulse generat...

Страница 16: ...24V 20 21 22 IN1 IN2 IN3 IN4 IN5 9 10 11 12 13 14 15 16 17 18 19 20 21 22 9 10 11 12 13 14 15 16 17 18 19 20 21 22 9 10 11 12 13 14 15 16 17 18 19 OP A OP B STOP CL FSW OP OUT1 OUT2 LK1 LK2 24V 20 21...

Страница 17: ...10 11 12 13 14 15 16 17 18 19 20 21 22 9 10 11 12 13 14 15 16 17 18 19 OP A OP B STOP CL FSW OP OUT1 OUT2 LK1 LK2 24V 20 21 22 IN1 IN2 IN3 IN4 IN5 TX CL RX CL 1 2 5 4 3 1 2 TX OP CL RX OP CL 1 2 5 4...

Страница 18: ...w faacgroup com The programming using a PC MAC with the de fault PASSWORD does not inhibit the program ming by board The writing PC will be displayed in correspondence with the modified values Notes w...

Страница 19: ...e default settings Y LO FUNCTION LOGICS E Semi automatic EP Semi automatic Step by Step S Automatic Safety Devices SA Automatic with reversal during pause SP Automatic Step by Step Safety Devices A1 A...

Страница 20: ...selected Adjustable from 00 to 59 sec in 1 second steps Next the value 59 the viewing changes to minutes and tenths of a second separated by a decimal point and time is adjusted in 10 second steps up...

Страница 21: ...motors are used power must be programmed to maximum level 50 25 En ENCODER USE You can enable disable the use of encoders both BUS and GATECODER encoders Y encoders on both motors no encoders disable...

Страница 22: ...error 14 configuration error until the SETUP is performed again or until the previous value is restored no Br SLIDING LEAF BRAKING displayed only if function CF 2 or CF PC Lets you set the braking tim...

Страница 23: ...the configuration you just performed 1 set the choice Y to SAVE and EXIT the programming no to EXIT the programming WITHOUT SAVING 2 press the button F to confirm at the end the display returns to vi...

Страница 24: ...y activating the motors at maximum power during final closing Y enabled for 2 sec no disabled In case of systems with an absolute encoder to enable this function a setup must be performed using the au...

Страница 25: ...RATION You can adjust the deceleration space as a percentage of the total travel of leaf 1 Adjustable from 00 to 99 in 1 steps 00 no deceleration 01 minimum deceleration space 99 maximum deceleration...

Страница 26: ...stacle detected in the same direction and position will be defined as a contact point and the leaf will stop in that position 00 minimum sensitivity maximum time before reversal 10 maximum sensitivity...

Страница 27: ...n active when OPENING and with automated system OPEN 14 timed output which can be activated from the second radio channel OMNIDEC see function t1 15 output which can be activated from the second radio...

Страница 28: ...the programmed number of cycles has been reached as defined in subsequent two functions nc and nd Signaling consists of a pre flashing of 8 sec in addition to the time may already be set with the fun...

Страница 29: ...choosing whether or not to save the configuration you just performed 1 set the choice Y to SAVE and EXIT the programming no to EXIT the programming WITHOUT SAVING 2 press the button F to confirm at t...

Страница 30: ...show the BUS 2EASY devices status see the figure 2 Perform the entry simultaneously press and hold and for at least 5 sec during this time the display will blink 3 Y will appear as a confirmation of...

Страница 31: ...of BUS device recognised through the entry 1 Press and hold the button during stand by visualisation the segments corresponding to at least one entered device will go ON E g To check the condition of...

Страница 32: ...nals 2 3 for leaf 1 motor and terminals 5 6 for leaf 2 motor 3 With the gate leaves closed launch SETUP by pressing and holding and until S1 begins to flash on the display about 3 sec 4 Release e Leaf...

Страница 33: ...PEN A pulse for stopping motion is ignored FC FC 02 02 the limit switch determines the start of deceleration send an OPEN A pulse only after involving the closing limit switch SET UP for SLIDING LEAFS...

Страница 34: ...n pause close regardless of the selected logic 6 1 MEMORISING THE SLH SLH LR RADIO CONTROLS 1 Press and hold R1 SW1 OPENAprogramming or R2 SW2 OPEN B CLOSE programming 2 After keeping the button press...

Страница 35: ...button of the memorised radio control twice in succession The automated system will perform an opening cycle Ensure that there are no obstacles by people or things during the automated system movemen...

Страница 36: ...indicating that memorisation has been completed and will begin flashing again for another 20 sec during which you can memorise other radio controls and will finally go off 6 3 MEMORISING DS RADIO CONT...

Страница 37: ...de 1 Press and hold R2 R2 2 After pressing for about 5 sec the DL12 LED begins to flash slowly after another 5 sec of slow flashing and holding the LEDs DL11 and DL12 begin flashing more rapidly cance...

Страница 38: ...DL J4 BAT1 CR2032 CONN ONNE NNE NNE NE ONNE NNE NNE NE NE E NNE NE NE E NE NE NE NE NE NE NE N NE E E E E E E NE E E E EC C C C C C C C CT C CT CT CT CT CTI CT CTIVI C C C C CT CT CT CTIV C CT TY Y Y...

Страница 39: ...ces have the same address 0 9 BUS 2EASY output short circuit Check the connections of the connected and entered BUS 2EASY devices 1 0 Motor 2 limit switch error Check the limit switch connections for...

Страница 40: ...at SETUP 2 8 Nr of consecutive obstacles exceeded during closing Remove any possible obstacle Should the problem persist repeat SETUP 3 0 XF radio code memory full Cancel the radio codes that are not...

Страница 41: ...correctly Repeat if necessary C The gate does not reverse when the photocells are engaged Check that the traditional photocells are correctly wired and that the BUS photocell configuration is correct...

Страница 42: ...generated named and placed as shown in fig in case of transfer from the board to the USB memory If at board power up a USB memory is detected inserted in the board J8 connector after displaying the wr...

Страница 43: ...sed simultaneously for at least 5 seconds you will access the board update The writing no will disappear and in its place the writing and the USB DL10 LED will begin flashing Once updating is complete...

Страница 44: ...ppear 00 Storage the Timer configuration file will be saved in the format E145_xxx trm where xxx 000 001 002 etc depending on how many Timer configuration files there are in the USB memory 0 1 Copy th...

Страница 45: ...uring pause they memorise closing during opening and immediately reverse during closing SA Automatic Safety reversing during pause An OPEN pulse opens the gate and closes automatically after the pause...

Страница 46: ...An OPEN pulse during opening is ignored during pause it resets the pause time and during closing it reopens the leaves The closing photocells recharge the pause time b Semiautomatic b OPEN B inputs b...

Страница 47: ...STOPS OPENS AT RELEASE OPEN STOPS SAVES CLOSE STOPPED RESTARTS MOVING IN THE OPPOSITE DIRECTION ALWAYS CLOSES AFTER STOP CLOSES NO EFFECT OPEN CLOSE DISABLED NO EFFECT OPEN DISABLED NO EFFECT CLOSE D...

Страница 48: ...HOUT PAUSE TIME STOPS OPENS AT RELEASE THEN CLOSES WITHOUT PAUSE TIME STOPPED CLOSES NO EFFECT OPEN CLOSE DISABLED NO EFFECT OPEN DISABLED NO EFFECT CLOSE DISABLED NO EFFECT OPEN CLOSE DISABLED S AUTO...

Страница 49: ...ES CLOSE STOPPED RESTARTS MOVING IN THE OPPOSITE DIRECTION ALWAYS CLOSES AFTER STOP CLOSES NO EFFECT OPEN CLOSE DISABLED NO EFFECT OPEN DISABLED NO EFFECT CLOSE DISABLED NO EFFECT OPEN CLOSE DISABLED...

Страница 50: ...EFFECT STOPS NO EFFECT REVERSES 2 STOPS OPENS AT RELEASE OPEN STOPS SAVES CLOSE STOPPED CLOSES NO EFFECT OPEN CLOSE DISABLED NO EFFECT OPEN DISABLED NO EFFECT CLOSE DISABLED NO EFFECT OPEN CLOSE DISA...

Страница 51: ...ES 2 STOPS OPENS AT RELEASE SAVES OPEN CLOSE STOPPED OPENS CLOSES NO EFFECT OPEN CLOSE DISABLED NO EFFECT OPEN DISABLED NO EFFECT CLOSE DISABLED NO EFFECT OPEN CLOSE DISABLED At AUTOMATIC WITH TIMER F...

Страница 52: ...ABLED CLOSING OPENS NO EFFECT STOPS NO EFFECT REVERSES 2 STOPS OPENS AT RELEASE SAVES OPEN CLOSE STOPPED OPENS CLOSES NO EFFECT OPEN CLOSE DISABLED NO EFFECT OPEN DISABLED NO EFFECT CLOSE DISABLED NO...

Страница 53: ......

Страница 54: ......

Страница 55: ......

Страница 56: ...Homebush Sydney Australia tel 61 2 87565644 www faac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 87134...

Отзывы: