INSTRUCTION MANUAL MT, MA2, MK2, M10 DRIVE UNIT
8
• Side installation
Mounting plate
1
The mounting plate is not manufactured by FAAC.
The measurement from the floor or other permanent entry level to the lower
edge of the mounting plate should be at least 2,550 mm.
The dimensions of the mounting plate should be 200 mm x 400 mm and
it should be at least 8 mm thick. It must be positioned according to the
enclosed assembly drawing. The mounting plate is to be anchored so that it
can withstand a torque of 2,000 Nm.
Lightweight concrete wall for example – through-going M10 bolts are used.
Concrete – 10 mm resin anchor.
Steel building – square tube onto a fixed building structure.
The mounting plate is also welded onto the gate surround.
Drive arm
2
Install the drive arm by removing the bolt and washer /
retaining ring on the output shaft from the drive unit and
pressing the arm into place.
Then reinstall the bolt and washer.