37
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Safety edge
No.
Name
Range
Factory Setting Ref. page
S
C101 Safety edge acknowledgement S.E1 (CPC)
0 – 1
0
0
Disabled
1
Enabled
S
C102 Function of output for external protection
0 – 4
0
0
Check disables, open output.
1
Closed to GND on activation, normally open.
2
Closed to +24VDC on activation, normally open.
3
Open on activation, normally closed to GND.
4
Open on activation, normally closed to +24VDC.
S
C103 Function of safety edge input during test of external
safety edge unit
1 – 2
1
1
Low resistance during test
2
High resistance during test
S
C112 Reversal/stop with activated safety edge S.E1 (CPC) 1 - 2
1
1
Reversal
2
Stop
S
C113 Check of external protection connected to S.E1
0 - 1
1
0
No check
1
Test of protection connected to S.E1
C114
Impedance readout S.E1 (CPC)
00.0-99.9 kΩ
S
C115 Set impedance value for safety edge S.E1 (CPC)
0.0 and 1.0-9.9 kΩ
8.2
S
C122 Reversal/stop with activated safety edge S.E2 (CPC) 1 – 2
1
1
Reversal
2
Stop
S
C123 Check of external protection connected to S.E2
0 - 1
1
0
No check
1
Test of protection connected to S.E2
C124
Impedance readout S.E2 (CPC)
00.0-99.9 kΩ
S
C125 Set impedance value for safety edge S.E2 (CPC)
0.0 and 1.0-9.9 kΩ
8.2
S
C132 Reversal/stop with activated safety edge S.E3 (CPO) 1 – 2
1
1
Reversal
2
Stop
S
C133 Check of external protection connected to S.E3
0 - 1
1
0
No check
1
Test of protection connected to S.E3
C134
Impedance readout S.E3 (CPO)
00.0-99.9 kΩ
S
C135 Set impedance value for safety edge S.E3 (CPO)
0.0 and 1.0-9.9 kΩ
0.0