DAAB COMMUNICATION CARD DB408 INSTRUCTION MANUAL
5
Channel reference
Interlock block
No.
Name
Range
Factory Setting
C664
Block of local door
0 – 3
0
0
No block
1
Block of open on local door until remote door is closed
2
Block of open on local door until remote door is open
3
Blocking of close on local door until remote door is closed
C665
In block of local door
0 – 3
3
0
Local door does not remember open and stop, stop does not cancel block of remote door
1
Local door remembers open and stop, stop does not cancel block of remote door
2
Local door does not remember open and stop, stop cancels block of remote door
3
Local door remembers open and stop, stop cancels block of remote door
C695
Network number for communication
0 – 2
0
0
Disabled
1
Automatic control unit no. 1 in communication
2
Automatic control unit no. 2 in communication
Содержание DAAB DB408
Страница 6: ......