FAAC DAAB DB408 Скачать руководство пользователя страница 5

DAAB COMMUNICATION CARD DB408 INSTRUCTION MANUAL

5

Channel reference

Interlock block

No. 

Name

Range

Factory Setting

C664

Block of local door

0 – 3

0

0

No block

1

Block of open on local door until remote door is closed

2

Block of open on local door until remote door is open

3

Blocking of close on local door until remote door is closed

C665

In block of local door

0 – 3

3

0

Local door does not remember open and stop, stop does not cancel block of remote door

1

Local door remembers open and stop, stop does not cancel block of remote door

2

Local door does not remember open and stop, stop cancels block of remote door

3

Local door remembers open and stop, stop cancels block of remote door

C695

Network number for communication

0 – 2

0

0

Disabled

1

Automatic control unit no. 1 in communication

2

Automatic control unit no. 2 in communication