![FAAC BFP1 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/faac/bfp1/bfp1_user-manual_535246002.webp)
DIP SWITCHES ON OFF FACTORY SETTING
1 Sensitivity high Sensitivity low (recommended ON
for mounting height < 2,2 m)
2 Passive mode Active mode OFF
3 Hold time : 2 sec Hold time : 0,5 sec OFF
A . M O U N T I N G T H E B F P 1
OPENING
AND
CLOSING
THE SENSOR
OPENING
AND
CLOSING
THE FSA
MOUNTING
THE SENSOR
• Use a small screwdriver to open the sensor
• Insert the screwdriver in the rectangular hole under the bracket cam
• Use it as a lever upwards
• Consider the position of the guide pin when inserting both legs of the
front cover to the base
• Gently push both sides of the front cover
• Insert the bottom of the front cover to the bottom clip of the base
• Push on the top of the front cover face
• Either use the screwdriver to open the FSA (left picture)
• Or pinch off both sides of the front cover (right picture)
• Rotate the front cover upwards
A . D I P S W I T C H E S S E T T I N G S A N D R E L A Y C O N F I G U R A T I O N S
B . S E N S I N G F I E L D P O S I T I O N
ON
2
1
3
SETTING
OF
THE SENSOR
ACTIVE MODE
PASSIVE MODE
DETECTION
NO DETECTION
DESCRIPTION
OF
THE PRODUCT
AND
THE SENSOR
• Wiring
• Inner view of the sensor front cover
• Description of the product
• Description of the sensor
12-24 V AC/DC
COM
NO
NC
1
2
3
4
5
O P E N I N G T H E
F S A A C C E S S O R Y
C L O S I N G T H E
F S A A C C E S S O R Y
• The LED flashes for a few seconds when the sensor is switched on
• The LED lights up through the lens when the sensor detects motion
The relay configurations are :
LED
SIGNAL
2,2 m
50 cm 50 cm 50 cm
1,5 m depth
3 m
PROFILE VIEW
2,2 m
50 cm 50 cm 50 cm 50 cm 50 cm
2,5 m
2,5 m
height 2,2 m
door
threshold
3 m
1,5 m
FRONT VIEW
FLAT VIEW
• Stick the template on the wall
• Drill the 2 holes to fix the FSA
and the hole for the cable
• Open the FSA (see page 2 :
opening and closing the FSA
Accessory)
• Cut the wire opening footprint
of the base
• Fix the sensor to the FSA base
with the 2 screws
• Connect the sensor to the cable
• Close the FSA (see page 2 :
opening and closing the FSA
Accessory)
Wire Opening Footprints
Main cable
Unplug 5-wire connector
2 screws to fix the BFP1
2 brackets
Lens
2 screws to fix the brackets with
the BFP1
Masking Lens (2 units)
Microprocessor
LED
Dip Switches
PYRO element
Guide Pins of the BFP1 base
Guide pins of the BFP1 base
Guide pins of the masking lens
COM (3)
NO (4)
NC (5)
COM (3)
NO (4)
NC (5)
COM (3)
NO (4)
NC (5)
COM (3)
NO (4)
NC (5)
ACCESSORY