SYMPTOMS
PROBABLE CAUSES CORRECTIVE ACTIONS
The door will not open and the LED does not light up The sensor is not properly powered a. Check the power supply
b. Check the supplied voltage
The door will not open and the LED lights up The wiring of the relay output is not Check the relay wiring
connected correctly
The door opens when no detection occurs and closes The mode of the relay output is Change the dip-switch #2 position
during a detection not correct
The sensing field does not correspond to your The cut of the masking lens is wrong Cut out a new lens to meet the required
requirements
sensing field size
TROUBLE-
SHOOTINGS
42
.00
06
/
V1
-12
.0
1
7
3293
7
-
Re
v.
A
FAAC S.p.A. - Via Benini, 1 40069 Zola Predosa - Italia - tel.+39 051 61724 - fax.+39 051 758518 - www.faacgroup.com
C . S E T T I N G T H E S E N S I N G F I E L D
• To adjust the sensing field according to your specific needs, use the masking delivered in the sensor box;
The minimum detection area at mounting height of 2.2 m is 0.5 m x 0.5 m
• To tailor the sensing field, cut segments
Remarks :
1) Be careful to cut just entire segments
2) It is necessary to cut at least one segment to get a detection
To insert the masking lens :
• Consider the position of the guide pins when inserting both legs of the masking lens to the front cover
• Gently push both legs of the masking lens
To remove the masking lens :
• Insert the screwdriver between the leg of the masking lens and the leg of the front cover
• Use it as a lever downwards
ASYMMETRICAL SENSING FIELD SHORTER DEPTH
S E N S I N G F I E L D
DETECTION AREA DETECTION AREA
±10 cm
±10 cm
door threshold door threshold
TECHNICAL
SPECIFICATIONS
THE MOST ADVANCED TECHNOLOGY IN PASSIVE INFRARED SENSOR RANGE
DESCRIPTION
INSTALLATION
TIPS
The passive infrared
sensor
FSA Accessory
for mounting on the wall
The
BFP1
is designed for use in opening of automatic doors with
small and medium sized sensing fields
It is not recommended for automatic doors with large sensing fields (BFR1 range is recommended) or automatic doors when shopping
carts or trolleys are used.
Technology
Passive infrared and microprocessor
Optical characteristics
P.I.R. with 4 elements, 15 Fresnel
lenses with full independent masking
possibilities
Mounting height
3 m max
Maximum Detection area for mounting height of 2.2m
2.5 m (W) x 1.5 m (D)
Minimum Detection area for mounting height of 2.2 m
0.5 m (W) x 0.5 m (D)
Detection mode
motion
Detection speed
0.1 to 1.5 m/s
Light indicator
1 red LED
Warm up
10 s
Hold time
0.5 s or 2 s
Response time
< 200 ms
Power supply
12 VDC –10% to 24 VDC +30%
12 to 24 V AC ±10%
Mains frequency
50/60 Hz
Power consumption
< 1 W
Connection
small plug-in 5 contacts connector
Recommended cable
section
< 0.5 mm
2
Length of cable
2.5 m
Temperature range
from –30°C to +55°C
Standard output relay
(free potential change-over contact)
• Max contact voltage 60 V DC/ 42 V AC
• Max contact current 1A (resistive)
• Max switching power 30W (DC) / 60 VA(AC)
Manual adjustments
• shape of sensing field (masking lens)
• sensitivity (dip switch #1)
• relay configuration (dip switch #2)
• Hold time (dip switch #3)
Immunity
electromagnetic compatibility (EMC)
according to 89/336/EEC and its
amendments.
•
Color
anthracite grey
•
Weight
40g
•
Dimensions
121mm (W) x 51mm (H) x 40mm (D)
•
Degree of protection
IP54
B F P 1
U S E R ’ S G U I D E
• The sensor must be firmly
fastened in order to avoid any
vibrations
NODETECTION
NO
DETECTION
Guide pins
Cut-Out footprints