![FAAC 885 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/faac/885/885_instructions-for-the-use_3183554009.webp)
9
Figure 5. The Manual Release Lever and Lock Solenoid (shown in the fail-safe position)
The fail-secure setting is handy in more secure
applications. However, it requires the user to manually
slide the lever to disengage the gate. Because the manual
release lever can be locked (with a padlock, not
included), it may even require the use of a key to
disengage the gate. If your application requires the use
of the fail-secure setting, you will need to follow the
procedure for remounting the solenoid lock.
Solenoid Lock Conversion
WARNING!
Turn off the main power before
making any electrical connections or attempting
to perform this conversion.
To convert the solenoid from fail-safe to fail-secure, you
will need a 10mm socket, a small flat blade screwdriver,
and a small pair of external snap ring pliers. Then, refer
to figures 4 and 5, and follow the steps below:
1.
Disconnect the two red solenoid wires at the
junction above the solenoid assembly.
2.
Remove the solenoid mounting bracket by
removing the two bolts (one on top, one on
bottom) and sliding the assembly to the right.
3.
Note the position of the solenoid return springs
(above and below the solenoid pin) and remove
them for safekeeping.
4.
Remove the two clip-in nuts that were used to
mount the solenoid bracket and install them in
the new bracket location (two square holes on
the other side of the manual release slide
assembly).
5.
Remove the manual release slide assembly (4
bolts) to gain access to the solenoid pin
assembly.
6.
Remove the lock pin guide plate (2 carriage
bolts with self-locking nuts).
7.
Remove the solenoid pin assembly (nylon slide
block with solenoid pin and lock pin) being
careful not to damage the solenoid switch.
8.
Next, remove one snap ring from the lock pin,
slide the pin out, re-insert the pin in the other
side so that it extends the opposite direction,
and re-install the snap ring.
9.
Follow steps 7-5 in reverse.
10.
Follow steps 3-1 in reverse, keeping in mind
that during step 2, the solenoid mounting
bracket will be installed in the new location on
the left side of the manual release slide
assembly.
The final step will be to set the SO function to n for
fail secure when you get to the programming stage.
Manual Release
Slide Assembly
Manual Release
Lever
Solenoid