Power supply

230V 3ph (+6 -10 %) 50Hz

400V 3ph+N (+6 -10 %) 50Hz

Motor max load

1,3 KW

Accessories power supply

24 Vdc

Accessories max load

500 mA

Warninig light power supply

24V~ (5W max)

T e m p e r a t u r e   r a n g e

- 20°C + 55°C

Fuses

transformer primary winding

accessories

Quick-fit plugs

 - for decoding cards or RP receivers -

OPEN

I n p u t s

PARTIAL OPEN

STOP

CLOSURE SAFETY DEVICES

LIMIT-SENSORS

warning light

O u t p u t s

flashlight

m o t o r

power supply to 24Vdc accessories

pause time (5-10-15-30-60-120-180 sec.)

Programming

                          logics A1/A2/S1/S2/E1/E2/B/C

pre-flashing

Motor braking

fixed

Safety timing

255 sec.

F1

Fuse F1 5x20  F5A/250V rapid (transformer)

F2

Fuse F2 5x20  T1,6A/250V delayed (accessories)

SW1

RESET push-button

DS1

Programming microswitches

Led

Input status signalling LEDs

J1

Quick-fit plug for decoding cards/RP receivers

J2

Low voltage terminal board for inputs/accessories

J3

Flashlight output terminal board (230V~  max 60W)

J4

Motor output terminal board

J5

Line power supply input terminal board

LK1

Bridge for warning light free contact

RL6-7

Motor relay

RL8

Braking relay

TF1

RL7

RL6

RL8

F1

F2

SW1

DS1

J1

J2

J3

J4

J5

A     B  STOP  FSW  FCC  FCA

LK1

F1

SW1

J1

Led

LK1

J2

J5

RL6

RL8

RL7

J3

J4

DS1

F2

These instructions apply to the following model:

844T Electronic control unit

This appliance can be installed in containers mod. E, L and
LM.  Before securing the card in the container, fit the supplied
support feet (long for mod. E, short for models L and LM) in the
3 S-holes (Fig.2).

1. TECHNICAL SPECIFICATIONS

844 T

Fig. 2

Fig. 1

1.1. 844T  LAY-OUT

Ü

Before attempting any work on the card (connections,

programming, maintenance), always turn off power.
Warning:  If plugs J3 and J4 are disconnected, high voltage
may be present on the flashlight and motor outputs.

TABLE 1

TECHNICAL SPECIFICATIONS  OF 844 T CONTROL UNIT

Observe points 10, 11, 12, 13 and14 of the GENERAL SAFETY RULES.
Always separate power cables from control and safety cables
(push-button  receiver, photocells, etc.).  To prevent any electrical
noise whatever, use separate sheaths.

a

b

Warn.Light

24 Vac

5W max

FAACLAMP

MINILAMP

230 Vac

Altre sicurezze
Other safeties
Autres sécurités
Andere Sicherheiten
Otros disp. seg.

M

3Ph

N R S T

OPEN A

OPEN B

STOP

1

2

1

2

3

4

5

1

2

3

4

5

1

2

FINECORSA
LIMIT SWITCH
FIN DE COURSE
ENDSCHALTER
FIN DE CARRERA

400 Vac 3ph + N - 50 Hz

TABLE 2

 844T CONTROL UNIT COMPONENTS

2. ELECTRICAL CONNECTIONS WITH 400V 3ph  (N.B.: for connection to 230 V 3ph, see Chapter 8)