5.2.

DESCRIPTION

5.2.1. CONNECTOR J1

The connector J1 is used for the quick connection of
MINIDEC,DECODER, RP RECEIVER boards (Figs. 21,22,23).
Accessory boards are to be inserted with their component
sides facing the inside of the 844MPSR electronic control unit.
Always disconnect the power supply before inserting or
removing accessory boards.

Fig. 20

5. 1. 3.

ELECTRICAL CONNECTIONS

Fig. 23

Fig. 22

Fig. 21

844

MPSR

844

MPSR

844

MPSR

5.2.2. TERMINAL BLOCK J2 (low voltage)

1

&

  5  = Common/Negative of accessor y power supply (-)

2 =

OPEN control device (N.O.)

Any control device (pushbutton, detector,..) which,
on closing the contact, relays an open and/or close
impulse to the gate.
To install more than one Open control device, con-
nect the N.O. contacts in parallel.

3 =

STOP control device (N.C.)

Any control device (e.g. pushbutton) w hich, on
opening a contact, stops the movement of the gate.
To install more than one Stop control device, con-
nect the N.C. contacts in series.
If no Stop control devices are to be connected,
place a jumper across the input and the common
terminal (terminal 1 or 5).

4 =

FSW closure safety device (N.C.)

Any control device (photocells, safety edges, mag-
netic loops) with an N.C. contact which interrupts

the movement of the gate when an obstacle is de-
tected within the protected area.
The task of the closure safety device is to safeguard
the area occupied by the gate during the closing
movement.
The inter vention of safety devices during gate clo-
sure causes the direction of gate movement to be
reversed. These devices do not inter vene dur ing
gate opening movements. If a closure safety device
is tripped when the gate is open or during a pause
time, they will prevent gate closure.
To install more than one safety device, connect the
N.C. contacts in series.
If no closure safety devices are to be installed, place
a jumper across this input and the common ter mi-
nal (terminal 1 or 5).

6

&

8 = 24V

~ accessories power supply

The maximum load of the accessories is 500 mA.
To calculate power draw, refer to the instructions for
the individual accessories.
If the jumper LK1 is broken, the 24V~ accessories
power supply is no longer available (Fig.28).

7 =

24Vdc

 accessories power supply positive (+)

The maximum load of the accessories is 500 mA.
To calculate power draw, refer to the instructions for
the individual accessories.

9 =

Electric lock output (12 Vac)

F o r   o p e ra t i o n   o f   t h e   e l e c t r i c   l o ck ,  re fe r   t o   t h e
dipswitch settings. If two electric locks are installed,
they must be connected in series.

5.2.3. CONNECTORS  J3-J4 (limit switch)

J3 = Connection of limit switch for left-hand closure
J4 = Connection of limit switch for right-hand closure

Refer to Figs. 24-25 for quick connection of the inductive limit
switch sensor for the corresponding gate closure direction.

J4

J3

J2

CH-DX

CH-SX

1     2     3     4     5     6     7     8     9

M

1

2

1

2

3

4

5

J5

J6

J8

J7

230V~ 50Hz

(+6%  -10%)

  C

35

µ

F

FAACLAMP
MINILAMP

Elettroserratura
Electric lock
Electroserrure
Elektrochloss
Electrocerradura

844MPSR

L

N

(L)

FINECORSA
LIMIT SWITCH
FIN DE COURSE
ENDSCHALTER
FIN DE CARRERA

1

2

3

4

5

1

2

Altre sicurezze
Other safeties
Autres sécurités
Andere Sicherheiten
Otros disp. seg.

a

b

MINIDEC
SL/DS

PLUS

844MPS

DECODER
SL/SLP/DS

844MPS

844MPS

Содержание 844 MPSR

Страница 1: ... and subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendments 92 31 EEC and 93 68 EEC and furthermore declares that unit must not be put into service until the machinery into which it is incorporated or of which it is a component has been identifie...

Страница 2: ... automation with a contact opening distance of 3 mm or more We recommend the use of a 6A thermal magnetic circuit breaker with multi pole switching 13 Ensure that a residual current device with a trip threshold of 0 03A is installed upstream of the automation system 14 Check that the earthing system is installed correctly and is efficient Connect the metal parts of the gate and the yellow green wi...

Страница 3: ...percentage of effective working time opening closing withrespecttothetotalcycletime opening closing pause times It is calculated using the following formula Ta Tc F X 100 Ta Tc Tp Ti where Ta opening time Tc closing time Tp pause time Ti interval between one complete cycle and the next Graph of duty cycle Fig 1 a Fixing angle bars b Pinion c Inductive proximity limit switch d Spare fuse housing e ...

Страница 4: ...ust be no pipes or electrical cables in the area to be dug for installing the foundation plinth If the gear motor is located in a vehicle transit area it is advisable to provide protection against accidental colli sions Check that the gear motor has an efficient earth connec tion 4 2 INSTALLING THE BASE PLATE 1 Assemble the base plate as shown in Fig 4 2 The base plate must be positioned as shown ...

Страница 5: ...6 Remove the breather screw as shown in Fig 13 and keep it in a safe place Fig 11 Fig 12 Fig 9 Fig 8 Fig 10 4 4 FITTING THE RACK 4 4 1 WELD ON STEEL RACK Fig 14 1 Mount the three threaded bushes on the rack element positioning them in the upper part of the slot In this way the play provided by the slot will allow for future adjustment 2 Slide the gate leaf manually to the closed position 3 Rest th...

Страница 6: ...put terminal block Fig 19 4 4 2 SCREW ON STEEL RACK Fig 15 1 Slide the leaf manually to the closed position 2 Rest the first rack element level on the pinion and insert the spacer in the upper part of the slot between the rack and the gate 3 Mark the point to be drilled on the gate Drill a 6 5 mm diameter hole and thread using 8 mm screw taps Tighten the bolt 4 Slide the gate manually making sure ...

Страница 7: ...ate movement to be reversed These devices do not intervene during gate opening movements If a closure safety device is tripped when the gate is open or during a pause time they will prevent gate closure To install more than one safety device connect the N C contacts in series If no closure safety devices are to be installed place a jumper across this input and the common termi nal terminal 1 or 5 ...

Страница 8: ... 4 and fig 28 LED ON contact closed LED OFF contact open TABLE 4 MEANING OF STATUS INDICATOR LEDS LED ON OFF OPEN Command active Command not active STOP Command not active Command active FSW Safeties disengaged Safeties engaged FCC Closing limit disengaged Closing limit engaged FCA Opening limit disengaged Opening limit engaged Fig 25 Fig 24 5 3 INSTALLING ELECTRIC LOCK Since the gear motor allows...

Страница 9: ...whentherespectivelimitswitchisengaged e g it is released before opening only if the closure limit switch is activated Pre flashing It is possible to select 5 seconds pre flashing of the flashing light before any gate movement This serves to warn any persons in the vicinity that the gate is about to start moving Install as follows Make sure that the upper guide upright is large enough to allow the ...

Страница 10: ...n inductive proximity limit switch Fig 1 ref 3 When the latter detects the passage of a plate fastened to the top of the rack it stops the movement of the gate To position the two travel stop plates correctly proceed as follows 1 Connect the limit switch connector to the 844MPSR con trol unit in accordance with the direction of gate closure paragraph 5 2 3 and Figs 24 25 2 Assemble the limit switc...

Страница 11: ...ecial applications 10 MAINTENANCE When performing maintenance always check that the anti crushingclutchiscorrectlyadjustedandthatthesafetydevices operate correctly 10 1 TOPPING UP WITH OIL Check the quantity of oil in the operator periodically For medium low duty cycles an annual check is sufficient for more intensive use check every 6 months To access the oil reservoir remove the oil filler cap F...

Страница 12: ...t of an opening impulse from a remote control or other suitable control device the control unit will start the motor to move the gate to the open position If automatic operation has been selected sending an impulse causes the gate to reclose on its own after the selected pause time If semiautomatic operation has been selected a second impulse must be sent to reclose the gate An opening impulse sen...

Отзывы: