4.3.

MECHANICAL INSTALLATION

1) Fix  the angle bars and the vibration dampers to the

operator as shown in Fig. 8.

2) Open the cover of the operator using the triangular key

supplied (Fig. 9).
The cover will remain in the open position thanks to a
locking system.

3) Fix the operator to the base plate using the nuts and

washers supplied (Fig. 10).
During this operation, route the cables through the conduit
in the lower half of the operator.
To access the  electronic equipment, route  the  cables
through the holes provided (13, Fig. 1) using the  grommets
supplied.

4) Adjust the height of the feet and the distance from the

gate as shown in Fig. 11.

5) Secure the gear motor onto the base plate by tightening

the nuts as shown in Fig. 12.

6) Remove the breather screw as shown in Fig. 13 and keep it

in a safe place.

Fig. 11

Fig. 12

Fig. 9

Fig. 8

Fig. 10

4.4.

FITTING THE RACK

4.4.1. WELD-ON STEEL RACK (Fig.14)

1) Mount the three threaded bushes

on the rack element, positioning
them in the upper part of the slot. In
this way the play provided by the
slot will allow for future adjustment.

2) Slide the gate leaf manually to the

closed position.

3) Rest the first rack element level on

the pinion and weld the first
threaded bush onto the gate as
shown in Fig. 16.

4) Slide the gate manually making sure that the rack rests on

the pinion. Weld the second and third bushes.

5) Position another rack element next to the first and use a

section of rack to set the teeth of the two elements in phase
as shown in Fig. 17.

6) Open the gate manually and weld the three threaded

bushes. Proceed in this manner until the rack covers the
entire length of the gate.

Fig. 14

Fig. 13

5 max

43

104 (Z12)

64

49

15 ÷ 32

Содержание 844 MC-R

Страница 1: ...and subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequen...

Страница 2: ...automation with a contact opening distance of 3 mm or more We recommend the use of a 6A thermal magnetic circuit breaker with multi pole switching 13 Ensure that a residual current device with a trip...

Страница 3: ...ercentage of effective working time opening closing withrespecttothetotalcycletime opening closing pause times It is calculated using the following formula Ta Tc F X 100 Ta Tc Tp Ti where Ta opening t...

Страница 4: ...st be no pipes or electrical cables in the area to be dug for installing the foundation plinth If the gear motor is located in a vehicle transit area it is advisable to provide protection against acci...

Страница 5: ...Remove the breather screw as shown in Fig 13 and keep it in a safe place Fig 11 Fig 12 Fig 9 Fig 8 Fig 10 4 4 FITTING THE RACK 4 4 1 WELD ON STEEL RACK Fig 14 1 Mount the three threaded bushes on the...

Страница 6: ...put terminal block Fig 19 4 4 2 SCREW ON STEEL RACK Fig 15 1 Slide the leaf manually to the closed position 2 Rest the first rack element level on the pinion and insert the spacer in the upper part of...

Страница 7: ...te movement to be reversed These devices do not intervene during gate opening movements If a closure safety device is tripped when the gate is open or during a pause time they will prevent gate closur...

Страница 8: ...4 and fig 28 LED ON contact closed LED OFF contact open TABLE 4 MEANING OF STATUS INDICATOR LEDS LED ON OFF OPEN Command active Command not active STOP Command not active Command active FSW Safeties d...

Страница 9: ...hentherespectivelimitswitchisengaged e g it is released before opening only if the closure limit switch is activated Pre flashing It is possible to select 5 seconds pre flashing of the flashing light...

Страница 10: ...inductive proximity limit switch Fig 1 ref 3 When the latter detects the passage of a plate fastened to the top of the rack it stops the movement of the gate To position the two travel stop plates co...

Страница 11: ...cial applications 10 MAINTENANCE When performing maintenance always check that the anti crushingclutchiscorrectlyadjustedandthatthesafetydevices operate correctly 10 1 TOPPING UP WITH OIL Check the qu...

Страница 12: ...of an opening impulse from a remote control or other suitable control device the control unit will start the motor to move the gate to the open position If automatic operation has been selected sendi...

Отзывы: