manualshive.com logo in svg
background image

11

ENGLISH

Notes on reading the instruction

Read this installation manual to the full before you begin installing the product.

The symbol

indicates notes that are important for the safety of persons and for the good condition of the automated system.

The symbol

draws your attention to the notes on the characteristics and operation of the product.

CE DECLARATION OF CONFORMITY 

Manufacturer

:

FAAC  S.p.A.

Address

:   

Via Benini, 1 - 40069 - Zola Predosa- BOLOGNA - ITALY

Declares that

:

Control unit model 

740 D

 powered on 230 Vac

 conforms to the essential safety requirements of the following EEC directives:

2006/95/EC Low Voltage directive.

2004/108/EC Electromagnetic Compatibility directive.

Additional information:

This product underwent a test in a typical uniform configuration (all products manufactured by FAAC S.p.A.).

Bologna, 28-02-2008

Managing Director

A. Bassi

INDEX

1. WARNINGS

page.12

2. TECHNICAL SPECIFICATIONS

page.12

3. LAYOUT AND COMPONENTS

page.12

4. ELECTRIC CONNECTIONS

page.12

 4.1. Connection of photocells and safety devices

page.13

4.2. J7 Terminal board - Power supply (fig. 2)

page.14

4.3. J6 Terminal board - Motors and flashing lamp (fig. 2)

page.14

4.4. J1 Terminal board  - Accessories (fig. 2)

page.14

4.5. Connector J2 - Rapid connection to Minidec, Decoder and RP

page.15

4.6. Connector J6 - Limit-switches rapid connection (fig.2)

page.15

4.7. Connector J3 - Encoder rapid connection (fig.2)

page.15

5. PROGRAMMING

page.16

5.1. BASIC PROGRAMMING

page.16

5.2. ADVANCED PROGRAMMING

page.16

6. START-UP

page.17

6.1. INPUTS CHECK

page.17

7. AUTOMATED SYSTEM TEST

page.17

Содержание 740

Страница 1: ...741 740D carta riciclata 100 per la natura for nature recycled paper 100 ist umweltfreundlich 100 Altpapier para la naturaleza 100 papel reciclado papier recycl 100 pour la nature voor de natuur 100...

Страница 2: ...st be checked as specified in the Standards indicated at point 10 16 The safety devices EN 12978 standard protect any danger areas against mechanical movement Risks such as crushing dragging and shear...

Страница 3: ...30 V 50Hz 230 V 50Hz 115 V 60Hz 115 V 60Hz Absorbed power W 350 500 350 600 Absorbed current A 1 5 2 2 3 5 2 Capacitor F 10 12 5 30 50 Thrust on pinion daN 45 65 45 65 Torque Nm 18 24 18 24 Winding th...

Страница 4: ...and rack engage correctly the foundation plate must be positioned as shown in Fig 05 right closing or Fig 06 left closing Warning The arrow on the foundation plate must always point to the gate see F...

Страница 5: ...1 5 mm Fig 15 Manually check if the gate correctly reaches the mechanical limit stops maintaining the pinion and rack coupled and make sure there is no friction during gate travel Do not use grease or...

Страница 6: ...orting side pieces Fig 19 ref 3 Apply the adhesive warning of danger to the upper part of the casing Fig 20 Give the Client the User Guide and demonstrate the correct operation and use of the gearmoto...

Страница 7: ...use time has elapsed If the semi automatic operation was set a second pulse must be sent to close the gate again An opening pulse during re closing always causes movement to be reversed A stop pulse i...

Страница 8: ...740 D...

Страница 9: ...h an intrinsic anti crushing safety device consisting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 of a torque control Nevertheless its t...

Страница 10: ...zu berpr fen Die Sicherheitsvorrichtungen Norm EN 12978 erm glichen den Schutz eventueller Ge fahrenbereiche vor mechanischen Bewegungsrisiken wie zum Beispiel Quetschungen 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 11: ...rective Additional information This product underwent a test in a typical uniform configuration all products manufactured by FAAC S p A Bologna 28 02 2008 Managing Director A Bassi INDEX 1 WARNINGS pa...

Страница 12: ...ng limit switches Enco der Terminal board outputs Flashing lamp Motor 24 Vdc accessories power supply 24 Vdc indicator light Timed output Fail safe Rapid connector 5 pin card connection for Minidec De...

Страница 13: ...ea against the risk of impact crushing shearing and dragging If two or more safety devices have the same function opening closing opening and closing edge the contacts must be connected to each other...

Страница 14: ...red standard PFor leaf opening direction see basic programming in Chpt 5 1 LAMP terminals 16 17 Flashing lamp output 230 V 4 4 J1 Terminal board Accessories fig 2 OPEN A Total Opening command terminal...

Страница 15: ...cted jumper connect the EDGE and inputs fig 5 Negative for power supply to accessories terminals 7 and 8 24 Vdc Positive for power supply to accessories terminals 9 and 10 Accessories max load is 500...

Страница 16: ...ement Useful for heavy leaves Y Active no Disabled Y ADVANCED PROGRAMMING F Display Function Default br FINAL BRAKING When the gate engages the opening or closing limit switch a braking stroke can be...

Страница 17: ...not exactly match the mo tor s maximum operating time because the latter is modified according to the performed deceleration spaces 4 1 AS ASSISTANCE REQUEST combined with next fun ction If activated...

Страница 18: ...N disabled OPEN on PAUSE Re closes the leaf immediately Stops operation No effect Reloads pause time OPEN disabled No effect OPEN disabled ON CLOSING Re opens the leaf immediately No effect saves OPEN...

Страница 19: ...EN disabled OPEN Re closes the leaf immediately Stops operation No effect No effect OPEN disabled ON CLOSING Stops operation No effect saves OPEN see paragraph 5 2 Stops and on release reverses on ope...

Страница 20: ...BC OPENING PULSES CLOSING COMMANDS ALWAYS PRESSED PULSES GATE STATUS OPEN A opening OPEN B closing STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP CLOS SAFETY DEVICE EDGE SAFETY DEVICE CLOSED O...

Страница 21: ......

Отзывы: