16
ENGLISH
ENGLISH
NOTE: To obtain a duty cycle of 100%, dip switch no. 6 must be
positioned as shown in Table 5.
NOTE: WHENEVER YOU CHANGE THE MICROSWITCH
PROGRAMMING, PRESS THE RESET PUSHBUTTON AFTERWARDS.
(*) IMPORTANT!:
The R logic (remote) must be selected
only if there are two opposing barriers working
simultaneously. (See paragraph "624 SLAVE CARD", below.)
OPERATION OF SAFETY DEVICES
In the A or E logics, it is possible to obtain two different
types of safety device operation, depending on the pause
times that are selected:
- PAUSE TIMES WITH LAMP PRE-FLASHING (10-20-30-40 sec):
the closing movement is stopped, then reversed on
disengagement.
- PAUSE TIMES WITHOUT LAMP PRE-FLASHING:(0-5-10-20 sec):
the closing movement is reversed at once.
ALARM CONDITION
It occurs in the following cases:
1)
Enabling of panic input.
2)
Activation of safety TIME-OUT device, which interrupts
the operation of the system when operating time
exceeds 30 sec.
3)
Simultaneous triggering of the two limit switches.
4)
Microprocessor reading anomaly (syncro).
The alarm condition is indicated by the quick flashing
(0.25 sec) of the warning light (if connected).
In this condition, all the functions of the system are
disabled. Normal operation is restored only after the
cause of the alarm has been eliminated and the RESET
pushbutton has been pressed.
OPERATION WITH THE DIFFERENT CONTROL LOGICS
Table 6 A Logic (AUTOMATIC)
Table 7
E Logic (SEMI-AUTOMATIC)
5.3. DESCRIPTION OF TERMINAL STRIP
OPEN
This means any activating device with normally open contact,
whose activation causes the beam to perform an opening
movement. In automatic and semi-automatic logics, it
controls both opening and closing movements.
CLOSE
This means any activating device with normally open
contact, whose activation causes the beam to perform a
closing movement. (Present only in P logic).
STOP
This means all devices with normally closed contact, which
when activated stop movement of the barrier until a subse-
quent Open pulse is sent.
SAFETY
This means all devices (photocells, sensitive pneumatic
safety edges, magnetic coils) with normally closed
contact, which interrupt the movement of the beam
whenever there is an obstacle within their range.
PANIC
This means an activating device with normally closed
contact, which is activated in an emergency and causes
the beam to open, suspending its current status until the
RESET pushbutton is pressed.
5.4. PROGRAMMING THE MICROSWITCHES
A / E LOGICS CONNECTIONS
Fig. 16
P LOGIC CONNECTIONS
Fig. 17
{
1
2
3
4
5
6
Logic
SW1
SW2
A
ON
ON
E
OFF
ON
P
ON
OFF
R(*)
OFF
OFF
Speed OP/CL SW6
OP=0.8 CL=2.2 ON
OP=0.8 CL=0.8 OFF
Pause Time
SW3 SW4 SW5
(sec)
Ø
OFF
OFF
OFF
5
ON
OFF
OFF
10
OFF
ON
OFF
20
ON
ON
OFF
10
OFF
OFF
ON
20
ON
OFF
ON
30
OFF
ON
ON
40
ON
ON
ON
With 5 sec. pre-flashing
of warning lamp
1 2 3 4 5 6 7 8 9 10
111213 14 15 16 17
N L
3
4
5
1
2
1
2
M
OPEN
NC
FX
NO
FX
FAAC
LAMP
24 VAC
MAX 5 W
VENTOLA
FAN
VENTILATEUR
LÜFTER
VENTILADOR
MOTOR
STOP
–
–
–
+
+
ANTIPANICO
PANIC ALARM
ANTIPANIQUE
PANIKSCHUTZ
ANTIPÁNICO
LAMPADA SPIA
WARNING LIGHT
LAMPE TÉMOIN
KONTROLLAMPE
TESTIGO
230 VAC +6% -10%
50 Hz
24 Vdc
+
–
1 2 3 4 5 6 7 8 9 10
111213 14 15 16 17
M
ANTIPANICO
PANIC ALARM
ANTIPANIQUE
PANIKSCHUTZ
ANTIPÁNICO
NC NO
FAAC
LAMP
24 VAC
MAX 5 W
MOTOR
STOP
–
–
+
OPEN
CLOSE
VENTOLA
FAN
VENTILATEUR
LÜFTER
VENTILADOR
LAMPADA SPIA
WARNING LIGHT
LAMPE TÉMOIN
KONTROLLAMPE
TESTIGO
24 Vdc
N L
230 VAC +6% -10%
50 Hz
Table 5
BARRIER MODEL
SW6
620 SR 0.8 - 2.2
ON
620 SR 0.8 - 0.8
OFF
(*) If pre-flashing has been selected, the barrier closes after 5 sec.
beam
status
impulse
opens, recloses after
pause time
recloses at once (*)
reverses movement
no effect
recloses at once (*)
no effect
freezes pause time up
to disengagement
see relevant
paragraph
no effect
no effect
no effect
stops counting
stops
stops
no effect
closed
open in pause
closing
opening
stopped
Beam opens and/
or remains open.
Alarm condition is
activated
(see relevant
paragraph)
OPEN
STOP
PANIC
SAFETY
beam
status
impulse
OPEN
opens
recloses (*)
reverses movement
stops
recloses (*)
closed
open
closing
opening
stopped
no effect
no effect
see relevant
paragraph
no effect
no effect
no effect
stops
stops
stops
no effect
STOP
SAFETY
PANIC
Beam opens and/
or remains open.
Alarm condition is
activated
(see relevant
paragraph)