ENGLISH

IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

1) WARNING!

 

FAAC strongly recommends to follow these instructions literally for the safety of persons. Improper

installation or misuse of the product will cause very serious damages to persons.

2) Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children.

3) Read the instructions carefully before installing the product.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly

set forth will affect the reliability of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by improper use or different from the use for which

the automation system is destined to.

7) Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.

8) Mechanical constructive elements must comply with UNI8612, CEN pr EN 12604 and CEN pr EN 12605 standards.

Countries outside the EC shall follow the regulations above besides their national normative references in order to offer
the utmost safety.

9) FAAC cannot be held responsible for failure to observe technical standards in the construction of gates and doors,

or for any deformation of the gates which may occur during use.

10) Installation must comply with UNI8612, CEN pr EN 12453 and CEN pr EN 12635.

The degree of safety of the automation must be C+E.

11) Before carrying out any operations, turn off the system’s main switch.

12) An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.

Alternatively, use a 6A thermomagnetic breaker with multi-pole switching.

13) Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.

14) Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the yellow/green

wire of the operator.

15) The automation is fitted with an anti-crush safety system that is a torque control device. In any case, further safety

devices shall be installed.

16) The safety devices (e.g. photocells, safety edges, etc.) protect areas where there is a mechanical movement hazard,

e.g. crushing, entrapment and cutting.

17) Each installation must be fitted with at least one flashing light (e.g. FAAC LAMP, MINILAMP etc.) as well as a warning

plate suitably fixed to the gate, besides the safety devices as per point 16. above.

18) FAAC cannot be held responsible regarding safety and correct functioning of the automation in the event that parts

other than FAAC original parts are used.

19) Use only FAAC original spare parts for maintenance operations.

20) Do not carry out any modifications to automation components.

21) The installer must supply all information regarding manual operation of the system in the event of an emergency and

provide the end-user with the "End-user Guide" attached to the product.

22) Keep out of persons when the product is in operation.

23) Keep out of reach of children the remote radio controls and any control devices. The automation could be operated

unintentionally.

24) The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be carried

out exclusively by qualified personnel.

25) What is not explicitly stated in these instructions is not permitted.

Содержание 593

Страница 1: ...undlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A...

Страница 2: ...sequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amend...

Страница 3: ...ll be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a different...

Страница 4: ...tout Anti crushing system bypass valve fitted as std Temperature range 20 55 C Housing protection IP 55 Weight kg 10 Pump flow rate l min 0 75 Angular velocity rpm 1 54 Max door weight 15 kg m2 Max to...

Страница 5: ...to size as shown in figs 6 7 Fit bushings C and brackets L on the drive shafts and secure brackets L on the door reinforcement ribbing taking care to maintain correct alignment of the drive shafts St...

Страница 6: ...g 4 Repeat the same operation for door closing by means of the red screw R fig 4 Correct adjustment is obtained when the door stops with a torque of approximately 15 kg measured on the lower edge of t...

Страница 7: ...periodically the quantity of oil inside the tank For medium low duty cycles a yearly check is sufficient for more severe operation it is advisable to check every 6 months The oil level must not be low...

Страница 8: ...1 ITALIANO B U A U L L C F Z S C Q Q T Q Q T R V E D D N M D D P Fig 2 Fig 3 Fig 1 Fig 4 Fig 7 Fig 6 Fig 5 S...

Страница 9: ...2 ITALIANO Fig 8 Fig 9 Fig 12 Fig 11 Fig 10 Fig 13 Fig 14 Fig 15 10 cm A B A B 10 cm 110 mm 25 mm N 5 4 mm T L...

Страница 10: ...inst atmospheric agents and can be fitted inside the garage The normal position of the door is closed in a vertical position When the electronic control unit receives an opening command from the remot...

Страница 11: ......

Страница 12: ...resentepublicaci n todaslasmodificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial FAAC S p A Via Benini 1...

Отзывы: