9. CONNECTIONS
9.1 Connect the power cable, as shown in figure 31, securing it with a clamp in the indicated area.
9.2 Fit the screw in the appropriate seat and tighten with washer
and nut (fig.31 ref.A).
9.3 Position the earth eyelet on the screw, add a washer and
tighten wit the nut (fig. 32 ref.A).
9.4 If you are using tube sleeves to secure the cables, make a slot
as shown in figure 32.
9.5 Screw the lamp in the appropriate lamp-holder.
9.6 Secure the operator housing using appropriate screws (fig.33).
Fig.31
A
Fig.32
A
Fig.33
To access the programming push-button, dismantle the cour-
tesy light ceiling fixture, unscrewing the appropriate screw.
Slide the ceiling fixture in the direction shown by the arrow (fig.34).
INITIAL SET-UP
The obstacle detector does NOT operate during this initial
procedure – this means that the operator is using the motor’s
maximum power to move the door.
Further, the Fail-safe procedure is not active.
The set-up procedure enables you to establish the following:
- anti-crushing safety levels at opening and closing.
- deceleration points
- operator’s fully open and fully closed points
- pause interval
This procedure can be carried out at any time, with the operator
in any position.
Two function logics are available on this appliance:
AUTOMATIC (TABLE 1)
SEMI-AUTOMATIC (TABLE 2)
10. PROGRAMMING