Step 5 - Fitting the door and seals
1. Assemble the handle onto the door. (There should be no metal toughing the glass. The spacers must be
used)
2. Assemble the hinges onto the hinged panel. (There should be no metal toughing the glass. The spacers
must be used). Lightly tighten the hinge bolts using an Allen Key.
• Make sure the hinges are assembled the correct way up. The hinge pin in the centre should only be able
to be removed fromo the top of the hinge. This is important - take time to check this.
3. Assemble the bottom seal onto the door and cut to length if necessary. The bottom seal must be positioned
flush up against the vertical magnet seal at one end of the door, and cut level to the end of the glass at the
other end of the door. See Fig: 5 (The seal must be cut square and accurately using a retractable knife or
alternative blade)
4. Lift the door towards the hinge panel and into location on the hinges. Make sure the panel seal flap sits
behind the door glass. Assemble the hinges onto the door. (There should be no metal touching the glass.
The spacers must be used). Lightly tighten the hinge bolts using an Allen Key.
5. Make sure the door deflector seal is locating its full length horizontally along the tray.
6. Align the hinges so they are at 90 degrees to the glass, check using a spirit level, when you are satisfied
tighten the hinge bolts to 10Nm using a torque wrench.
•
(You will need help to perform the installation steps, particularly to lift and hold the front panel into
location).
7. Close the door onto the front panel, with the door closed align the magnets so that the door and panel
magnets locate evenly the full length.
•
You may need to move the magnets towards each other to achieve a seal.
•
You may need to adjust the bracing on the panels so that the dor and panel meet.
Door seal flush
with magnet seal
Door seal cut level to
the end of the glass
➂
➂
➄
➀
➆
➃
FA - Freedom Arc Dec 2009:CQB
4/5/10
12:05
Page 6