F.W. Bell 4180 Скачать руководство пользователя страница 5

INTRODUCTION

 

1-2 

General Operating Instructions and Application 
 

The 4100 Series ELF gaussmeter is designed to measure only AC magnetic fields. These include but are not 
restricted to the 50/60 Hz magnetic field emanating from power lines. ELF is an acronym similar to VHF or 
UHF as used for television band frequencies. ELF stands for 

E

xtremely 

L

ow 

F

requency and is defined as the 

band of frequencies from 30 to 300Hz. Although this meter will measure fields considerably above and below 
those defined limits, this is usually the bandwidth of primary interest since most ELF magnetic fields are power 
line related and within this bandwidth. 
 
To operate the 4100 Series meters, first press the ON/OFF button and wait for unit to initialize. Unit will start up 
in the last state it was when powered off.  Move the 4100 towards a source of ELF radiation.  Most appliances 
that plug into a standard wall socket and have a motor or power transformer or that draw higher currents will 
emit magnetic radiation when turned on. You should notice a change in the displayed reading as you move 
closer to the source of a radiated magnetic field. 
 
When you begin using the ELF gaussmeter, you will often find that the ELF field strength is strongest in one 
particular area.  For example, your computer screen (CRT) may have its greatest field level directly in the back 
of it, thus affecting those around you.  A bedside clock radio may emit a higher field level from its side where 
the power supply circuitry is located. You can effectively reduce your exposure to ELF magnetic fields by first 
locating the areas in your home or workplace where levels are the highest, and then by rearranging your living 
space in a way that minimizes your exposure. 
 
Hold the meter in front of and around the source of magnetic radiation, and position the meter in various 
locations until a maximum reading is obtained.  Both the 4180 and the 4190 are three-axis meters and an 
individual axis can be selected.  Take time to become familiar with this process and you will see that the 
reading displayed is greatly affected by the orientation of the meter when operating in single-axis mode.  This 
is because the magnetic field not only has a magnitude or level but also a direction as well.  The meter 
responds to the magnetic fields whose direction is aligned with the axis selected on the meter.  Fields parallel 
in direction to the axis of the meter which has been selected will show a high reading in that direction and a low 
reading in others. 
 
Always keep these important points in mind when using the meter:  
(1) One single axis can be selected for finding the general direction of the field.  When operating in single axis 
mode the position of the meter should be oriented in various directions until the maximum reading is obtained.   
(2) The maximum reading will give the true indication of field strength at that particular location. 
(3) In 3-axis mode (XYZ) the 4100 will indicate the field strength, but no directional information. 
 
The above process can be repeated at various locations to determine the area in the home or workplace 
where ELF magnetic fields are present.  The Models 4180 and 4190 can assist you in locating the sources of 
ELF magnetic radiation in the home or workplace, and thus allow you to take prudent steps to reduce your 
exposure.  As with most other forms of radiation, the level decreases as the distance from the source 
increases. 
 
Under normal operating conditions, the unit will provide about 30 hours of continuous operation using Alkaline 
batteries, or 20 hours for NiMH rechargeable batteries. When the battery voltage falls below approximately 
4.44 volts (1.11 volts per cell), a low battery indicator on the LCD will be activated. Most rechargeable cells 
have a nominal voltage of 1.2V compared to 1.5V for alkaline cells, therefore the useable time before a low 
battery condition is indicated will be shorter than for alkaline batteries. However, if the meter is used frequently, 
rechargeable batteries will generally be much more economical since they may be re-used many times. 
Batteries contain ferrous magnetic materials which can alter the sensitivity of field readings if removed. The 
meter was calibrated at the factory with batteries installed. 

Содержание 4180

Страница 1: ...4100 Series ELF Gauss Tesla Meter Instruction Manual Manual UN 01 263 Rev F OECO LLC All rights reserved ...

Страница 2: ...ating Instructions 1 2 SECTION 2 SPECIFICATIONS Meter Specifications 2 1 SECTION 3 OPERATING INSTRUCTIONS Keypad layout and functions 3 1 Meter Ports 3 3 Display Layout 3 3 Advanced Measurements 3 3 SECTION 4 SOFTWARE AND USB PORT Introduction 4 1 Connecting the 4100 Series to a PC 4 2 WARRANTY 5 1 ...

Страница 3: ...ing of most of the materials in an appropriate manner The crossed out wheeled trash bin symbol indicates compliance with the European Union Directives 2012 19 EU and 2006 66 EC on Waste Electrical and Electronic Equipment WEEE and batteries For information on recycling options please check the Meggitt Sensing Systems Recycling website http www meggittsensingsystems com WEEE recycling index html Ro...

Страница 4: ... a given area It is commonly assigned the symbol B in scientific documents In the CGS system a gauss G is one line of flux passing through a 1 cm2 area The more commonly used term is the tesla T which is 10 000 lines per cm2 Thus 1 tesla 10 000 gauss 1 gauss 0 0001 tesla Magnetic field strength is a measure of force produced by an electric current or a permanent magnet It is the ability to induce ...

Страница 5: ...s and you will see that the reading displayed is greatly affected by the orientation of the meter when operating in single axis mode This is because the magnetic field not only has a magnitude or level but also a direction as well The meter responds to the magnetic fields whose direction is aligned with the axis selected on the meter Fields parallel in direction to the axis of the meter which has ...

Страница 6: ...0 4mG 40 to 80Hz Not applicable 1 5 2mVdc DC mode 2 0 4mVac AC mode Analog Output Frequency Response Referenced to 55Hz Not applicable 25 to 1200Hz 5 10mV 20Hz to 2kHz 3dB Communications Port Type mini B 5 pos USB 2 readings sec max Data Logging Software No Yes Models 4180 and 4190 Battery Type 4 AAA Alkaline 1 5V or NiMH 1 2V Battery Life Typical 30 hours for alkaline 20 hours for 850mAh NiMH Ope...

Страница 7: ...Y This key is used for activating the 4190 s additional features Hold Reset and Analog Output The model 4180 meter will not respond to this key since it does not have these features 3 AXIS Select RESET The displayed reading can be changed to show the X Y or Z axis or the vector summation of X Y and Z by pressing the AXIS key Model 4190 only When the SHIFT key is pressed followed by the AXIS key an...

Страница 8: ... connected to a PC via the USB 2 0 port The 4190 can perform Data logging and be commanded through this port with the 4190 application software Remote automation can also be performed through this port The 4100 may also be powered from the 5 volt line of the USB connector thus drawing its power from the computer to which it is attached 7 Analog Output Connector 4190 only A voltage signal represent...

Страница 9: ...s for the field level readings are found on the right hand side of the display By pressing the UNITS key the meter will toggle between µT or mG This function is operational while the HOLD or REL functions are active See figure 3 3 MIN MAX HOLD Model 4190 only When the HOLD function is activated with the SHIFT HOLD key sequence MIN will be shown in the bottom left hand side of the LCD Pressing the ...

Страница 10: ...ing controlled remotely the range may be set to low high or auto range via software commands Advanced Measurements Basic ELF gaussmeter operational procedure is found in Section 1 of this manual When conducting ELF field measurements one should take advantage of the features the 4100 series meters have to offer When conducting a measurement the user can use the RELATIVE feature to compare field st...

Страница 11: ...tallation software will also install the drivers for the meter After the software is installed the powered up meter can be connected to a USB cable and connected to the PC Software Development with third party Application Programming Interface API Both the 4180 and 4190 may be controlled by customer written software through the API file fwb4100 dll Many higher level programming languages and devel...

Страница 12: ...TIES EXPRESSED OR IMPLIED AND ALL OTHER OBLIGATIONS AND LIABILITIES ON THE PART OF OECO AND NO PERSON INCLUDING ANY DISTRIBUTOR AGENT OR REPRESENTATIVE OF OECO IS AUTHORIZED TO ASSUME FOR OECO ANY LIABILITY ON ITS BEHALF OR ITS NAME EXCEPT TO REFER THE PURCHASER TO THIS WARRANTY THE ABOVE EXPRESS WARRANTY IS THE ONLY WARRANTY MADE BY OECO OECO DOES NOT MAKE AND EXPRESSLY DISCLAIMS ANY OTHER WARRAN...

Отзывы: