How to SELECT and RUN an APPLICATION

  

 

Program number 27 shall be used 

 

Connect the 3.5mm plug of the application cable to the socket located on the 
front side of the device below the label     
 
Connect the  application cable to the self adhesive pads or the alligator clips 
wit wet towels. For NON DUO applications, the black connection is not 
necessary. 

 

 

 

 
1. 

Switch on

 

 

 
 
 
 
 

2. 

List

  

 
 
 

 
 

3. 

Select with 

 
 

 

 

 

 

 

 

Содержание F-SCAN COMPACT DUO

Страница 1: ...1 Frequency Synthesizer F SCAN COMPACT DUO Firmware Version FSC V2 1x with100 memory banks INSTRUCTION MANUAL This symbol identifies the equipment as Type B ATTENTION Consult accompanying documents...

Страница 2: ...2...

Страница 3: ...Soft keys F1 F2 F3 13 Memory banks for user defined applications 14 Start a user defined application 16 DUO MODE 16 Input of decimals 17 Name an application 18 TIMER 18 Change the amplitude of signal...

Страница 4: ...inute 100 memory banks for up to WARNING User with Pacemaker pregnant women and electro sensitive persons should consult a medical professional prior to connecting to the F SCAN COMPACT DUO WARNING Th...

Страница 5: ...ne frequency value to the next to avoid unwanted discharge impacts for the user The signal amplitude is reduced to zero for the frequency exited and raised from zero to the operating level for the new...

Страница 6: ...ads Instruction manual not shown Default settings Display language English 2nd choice German Runtime per Frequency 3 00 minutes range 0 30 to 60 00 minutes Amplitude of signals 40 of maximum of 12Vpp...

Страница 7: ...n the battery Mini USB Connector Connect to PC Notebook or power supply to charge Lithium Ion battery via USB cable Graphical monochrome LCD display SOFT keys F1 F2 F3 Tasks for each key are defined i...

Страница 8: ...8 Signals sent to the output port To improve efficacy a small portion of a 10 MHz wave is modulated on the output signals SINE 3 Vpp SQUARE DC OFFSET positive 0Vpp to 12Vpp...

Страница 9: ...MAY SHOW APPEARING AND DISAPPEARING STRIPES DURING THE CHARGING AND THE DEVICE MAY WARM UP SLIGHTLY THESE EFFECTS ARE NORMAL IF YOUR DEVICE IS EQUIPPED WITH WIRELESS CHARGING OPTION Place the F SCAN...

Страница 10: ...battery supports minimum of 3 hours of continuous stand alone operation The Lithium Ion battery does not age prematurely if the device remains connected to a power source whenever it is not used stand...

Страница 11: ...plug of the application cable to the socket located on the front side of the device below the label Connect the application cable to the self adhesive pads or the alligator clips wit wet towels For N...

Страница 12: ...ke the hand holds or position the self adhesive pads 5 Start with or Program 27 holds 8 frequency values and completes the application within 24 minutes The device switches OFF automatically two minut...

Страница 13: ...or until a reset to the default settings A brief touch stops the active frequency and starts the next one in line stops the application for a pause PAUSE flashes and the signal amplitude AMP shows 0...

Страница 14: ...her or one sequence only will be described later in this document Example how to enter frequency values of 100 Hz 200 Hz and 1234 Hz in memory location number 1 1 Switch on with CENTER 2 Select with C...

Страница 15: ...00 Confirm with CENTER Now the second value F 200 Hz is memorized in bank 1 7 Input of a frequency 8 enter 1234 Hz F 1 times 10 F 10 Plus 1 F 11 Plus 1 F 12 times 10 F 120 Plus 1 F 121 Plus 1 F 122 Pl...

Страница 16: ...This means that the first frequency F1 of a program outputs the signal on the red wire of the cable FTB033 The second frequency indicated as F2 is output at the black wire of the application cable Th...

Страница 17: ...is flowing Input of decimals Some applications mentioned in the literature call for use of frequencies with up to 2 decimals i e 8 82 Hz The F SCAN COMPACT DUO offers this feature 1 Input a frequency...

Страница 18: ...character With KEY CENTER the entry will be confirmed and memorized TIMER Change the runtime per frequency The factory default for each frequency value issued by the F SCAN COMPACT DUO is 3 00 minute...

Страница 19: ...how to change the amplitude from 80 to 75 1 Switch on 2 Select DEVICE SETTINGS 3 Confirm with CENTER 4 Confirm with CENTER 5 Set amplitude to 75 press KEY DOWN 5 times 6 Terminate SET AMPLITUDE NOTE...

Страница 20: ...equency 3 00 minutes range 0 30 to 60 00 minutes Amplitude of signals 40 of maximum of 12Vpp adjustable in steps of 1 Wave form AUTO square DC Offset Program number 1 of table and Example how to reset...

Страница 21: ...ared They will be ready for new input Example how to clear all user memory banks 1 Switch on 2 Select DEVICE SETTINGS 3 Confirm with CENTER 4 Select CLEAR USER MEMORY press KEY DOWN 3 times 5 Now pres...

Страница 22: ...onfirm with CENTER Memory bank 10 has 3 entries 3 Press SOFT KEY F3 until a beep The last Frequency of Memory bank no 10 will be cleared and the message 02 FREQUENCIES is displayed Keep SOFT KEY F3 pr...

Страница 23: ...ATIONS between two F SCAN COMPACT DUO devices It can also be used to transfer one application from an F SCAN COMPACT DUO to an F SCAN MinDevice Data exchange between F SCAN3 F SCAN4 and F SCAN MOBILE...

Страница 24: ...tched OFF COPY TO ChipCard If selected and confirmed with CENTER all applications including their names stored in the function INDIVIDUAL APPLICATIONS replace the content of the ChipCard The procedure...

Страница 25: ...the transferred application is now read automatically and stored in the device the green LED in the middle blinks until the transfer is completed Switch the MinDevice OFF and remove the ChipCard Chip...

Страница 26: ...ct the names of the applications stored The device must be reprogrammed at the factory to incorporate the German names CONDUCTIVITY VALUE CV and functional test of the APPLICATION CABLE A CV value app...

Страница 27: ...de 3Vpp Square DC Offset Amplitude 0 12Vpp Output range 1Hz to 100 kHz Changes to improve or simplify the product will be made without prior notice Declaration of Conformity Herewith we declare TB ELE...

Страница 28: ...28...

Отзывы: