USE

 

CAUTION: Sector of use

   For irrigation and watering of lawns, gar

-

dens, vegetable patches, etc.

 

For  drawing  water  from  ponds,  streams, 

water butts and wells, subject to fitting of 

suitable filter.

ACCEPTABLE LIQUIDS

In order to pump clear water (fresh water), rainwa

-

ter or non-aggressive chemical cleaning solutions. 

Abrasive liquids or any other type of corrosive liq

-

uid could damage or destroy the pump.

OPERATING INSTRUCTIONS

It is recommended to use a preliminary filter and 

exhauster with a suction hose, suitable and foot 

valve (reflux lock) to avoid long suction times and 

pointlessly damaging the pump due to stones and 

solid foreign bodies.

BEFORE STARTING

Before starting for the first time, the pump has 

to be filled through the delivery union with the 

delivery liquid until it overflows.

SUCTION PIPING

 

ƒ

Fit  the  water  suction  pipe  so  that  it  points  up

-

wards towards the pump. Absolutely avoid fitting 

the suction pipe higher than the pump (formation 

of air bubbles in the suction pipe).

 

ƒ

The suction and delivery piping must be fitted so 

as not to be able to apply any mechanical pressure 

on the pump.

 

ƒ

The suction valve should be situated at least 30 cm 

below the bottom water level.

 

ƒ

Suction pipes that are not airtight suck in air ob

-

structing suction of the water.

DELIVERY PIPING

During suction, the cut-off parts (sprayers, valves, 

etc.) situated in the delivery piping have to be fully 

open so that the air in the suction pipe can be free

-

ly expelled.

MAINTENANCE INSTRUCTIONS

The  irrigation  pump  is  entirely  maintenance-free. 

Should the pump become blocked, first try rinsing. 

Should  it  turn  out  that  the  blockage  is  due  to  the 

inefficiency or complete absence of the filters, dis

-

mantle  the  hydraulic  section  and  thoroughly  rinse 

the interior, carefully reassemble and refit the filters 

correctly before turning back on.

 

ƒ

If there is a risk of frost, the pump has to be emp

-

tied completely.

 

ƒ

When the pump is not going to be used for a long 

time, for instance in the winter period, it is recom

-

mended  to  rinse  out  the  pump  thoroughly  with 

water,  empty  it  completely  and  store  it  in  a  dry 

place.

 

ƒ

Before restarting, check whether the pump works 

freely by briefly connecting and disconnecting it.

 

ƒ

Then fill the pump again with the delivery liquid 

and set it up for use.

 

CAUTION!  In  order  to  work,  the  pump 

must always be filled with the delivery liq

-

uid until it overflows!

 

CAUTION!  The  pump  must  never  run  dry. 

The  manufacturer’s  warranty  is  null  and 

void  in  the  event  of  damage  to  the  pump 

caused by its running dry. Check that the 

pump is airtight, in fact not airtight pipes 

draw in air preventing the pump from work

-

ing properly.

ENVIRONMENTAL PROTECTION

Information on the disposal of electric and 

electronic  equipment  in  compliance  with 

directive 2002/96 CE (RAEE). 

Warning: do not use the normal house trash 

bin to dispose of this product. 

Used  electric  and  electronic  equipment 

must be handled separately and in compli

-

ance  with  the  regulations  relating  to  the 

treatment,  recovery  and  recycling  of  the 

said products. 

In accordance with the regulations applied 

in  the  member  States,  private  users  resi

-

dent  in  the  EU  can  take  used  electric  and 

electronic equipment free of charge to des

-

ignated collection centers. 

If  you  experience  difficulties  in  locating 

an  authorized  disposal  center,  consult  the 

dealer from whom you purchased the prod

-

uct. 

The national regulations provide sanctions 

against whoever unlawfully disposes of or 

abandons  waste  of  electric  or  electronic 

equipment. 

GUARANTEE

This product is warranted in accordance with the le

-

gal/country specific regulations, effective from the 

date of purchase by the first user. Damage attribut

-

able to normal wear and tear, overload or improper 

handling  will  be  excluded  from  the  guarantee.  In 

case of a claim, please send the machine, complete

-

ly assembled, to your dealer or the service center for 

electric power tools.

Содержание SPP 800X

Страница 1: ...ORIGINAL INSTRUCTIONS EN NOTICE ORIGINALE FR ISTRUZIONI ORIGINALI IT EL ORIGINALNO UPUTSTVO ZA RAD SR INSTRUC IUNI DE FOLOSIRE ORIGINALE RO BG ORIGINALNE UPUTE ZA RAD HR SPP 800X SPP 1200X SPP 800...

Страница 2: ...ELETTROPOMPA JET SS 43485 ELETTROPOMPA JET 08 EL 43483 43484 JET INOX 43485 JET 10 SR 43483 43484 PUMPA JET SS 43485 PUMPA JET 12 HR 43483 43484 CRPKA JET SS 43485 CRPKA JET 14 RO 43483 43484 POMP JE...

Страница 3: ...3 www ffgroup tools com SPP 800X SPP 1200X SPP 800...

Страница 4: ...it is plugged into the mains f Make sure that the plugged electrical connections are in an area safe from flooding and are protected from humidity f Before use it is necessary to check that the plug...

Страница 5: ...before turning back on If there is a risk of frost the pump has to be emp tied completely When the pump is not going to be used for a long time for instance in the winter period it is recom mended to...

Страница 6: ...e d alimentation branch au r seau f Assurez vous que les branchements lectriques se trouvent l abri des inondations et de l humidit f Avant l utilisation v rifiez si la ligne de branche ment au r seau...

Страница 7: ...remonter soi gneusement remettre les filtres correctement et effectuer la mise en service En cas de risque de gel la pompe doit tre com pl tement vid e Avant une longue p riode d inutilisation de la...

Страница 8: ...ne collegato alla rete f Assicurarsi che le connessioni elettriche a spina si trovino in una zona sicura da allagamenti e siano pro tette dall umidit f Prima dell uso occorre verificare che la linea d...

Страница 9: ...ltri in modo corretto ed effettuare la messa in funzione In caso di pericolo di gelo la pompa deve essere svuotata completamente Prima di un lungo periodo di inutilizzo della pom pa per es nel periodo...

Страница 10: ...F 1mm DIN 57282 DIN 57245 f dbA 85 dbA f 230 Volt f 35 C f f f f f f f f f 1 2 3 43 483 43 484 43 485 SPP 800X SPP 1200X SPP 800 V 230 230 230 Hz 50 50 50 W 800 1200 800 m 38 46 38 L h 3200 3700 3500...

Страница 11: ...11 www ffgroup tools com SPP 800X SPP 1200X SPP 800 o C 35 35 35 m 1 1 1 kg 6 4 7 7 6 4 IPX4 IPX4 IPX4 B B B 30 2002 96...

Страница 12: ...ok je uklju en u struju f Proverite da li se priklju eni elektri ni priklju ci nalaze u podru ju koje je bezbedno od poplavljivanja i za ti eno od vlage f Pre upotrebe je neophodno proveriti da li su...

Страница 13: ...vite i vratite filtere na mesto pre ponovnog uklju ivanja Ako postoji rizik od mraza pumpu treba potpuno isprazniti Kada se pumpa ne koristi u du em preriodu na primer tokom zime preporu uje se da je...

Страница 14: ...i priklju ci nalaze u podru ju koje je sigurno od poplave i za ti eno od vlage f Prije upotrebe provjerite da utika i vod elektri nog napajanja nisu o te eni f Iskop ajte utika iz uti nice prije izvo...

Страница 15: ...filtre prije ponovnog uklju ivanja Ako postoji rizik od zamrzavanja crpku je potreb no potpuno isprazniti Ako crpku ne ete koristiti neko vrijeme primjerice zimi preporu ujemo da temeljito isperete cr...

Страница 16: ...priz sunt ntr o zon ferit de riscul de inunda ii i sunt protejate de umiditate f naintedeutilizareestenecesars verifica idac te cherul i circuitul de alimentare nu sunt deteriorate f Deconecta i de l...

Страница 17: ...ct nainte s porni i din nou pompa Dac exist un risc de nghe pompa trebuie go lit integral C nd pompa nu va fi folosit o perioad ndelun gat de exemplu n perioada de iarn se reco mand cl tirea pompei cu...

Страница 18: ...NF 1 DIN 57282 DIN 57245 f dbA 85 dbA f 230 f 35 C f f f f f f f f f 1 2 3 43 483 43 484 43 485 SPP 800X SPP 1200X SPP 800 V 230 230 230 Hz 50 50 50 W 800 1200 800 m 38 46 38 L h 3200 3700 3500 m 8 8...

Страница 19: ...19 www ffgroup tools com SPP 800X SPP 1200X SPP 800 m 1 1 1 kg 6 4 7 7 6 4 IPX4 IPX4 IPX4 B B B 30 2002 96 EO OEEO...

Страница 20: ...trigger again approx 20 mins FRAN AIS R SOLUTION DES PROBL MES PROBL ME CAUSES REMEDIES Le moteur ne d marre pas Absence alimentation lectrique Couronne pompe bloqu e Thermostat d branch V rifier l a...

Страница 21: ...a valvola aspirante min 30cm Versare acqua nel raccordo aspir Verificare la tenuta del tubo aspir Pulire la valvola aspirante Pulire il filtro Controllare l altezza di aspirazione Portata insufficient...

Страница 22: ...e pumpu i zamenite dotrajale delove Pumpu isklju uje za tita od pregrevanja Preoptere enje motora Prekomerno trenje je izazvano stranim telima Elimini ite strana tela Sa ekajte da se ponovo aktivira p...

Страница 23: ...ra ie min 30 cm A se turna ap n racordul de aspira ie Se verifica etanseitatea circuitului de aspira ie A se cur a supapa de aspira ie A se cur a filtrul A se controla n l imea de aspira ie Debit insu...

Страница 24: ...uenti Normative 43 483 43 484 ELETTROPOMPA JET SS 43 485 ELETTROPOMPA JET Codice prodotto EL 43 483 43 484 JET INOX 43 485 JET SR EU IZJAVA O USAGLA ENOSTI Na sopstvenu odgovornost izjavljujemo da nav...

Страница 25: ...1 2012 A11 A13 EN60335 2 41 2003 A1 A2 EN 62233 2008 EN Technical file at FF GROUP TOOL INDUSTRIES 19300 Aspropyrgos Greece Loudovikos Tsirigiotis Operations Engineering FF GROUP TOOL INDUSTRIES 1930...

Страница 26: ...26 SPP 800X SPP 1200X SPP 800...

Страница 27: ...27 www ffgroup tools com SPP 800X SPP 1200X SPP 800...

Страница 28: ...www ffgroup tools com info ffgroup toolindustries com 30 210 55 98 400 19300 Athens Greece 9 5 Km Attiki Odos Aspropyrgos FF GROUP TOOL INDUSTRIES...

Отзывы: