Modifying a Target Menu

Before attempting to modify a target menu, it is recommended you write the menu in a table

format (Use a copy of the table form provided in Appendix #2) and work with the table in front

of you. Determine the desired release mode for each pair. The release modes available are:

Release

mode

Symbol When pressing the Fire [

] key

True Pair

1

+

 2

Two targets release simultaneously

Report Pair

1

>

 2

First target released. RED light ON steady. Press the fire [

] key

again upon shooters gunshot (report) to throw the second target.

Following Pair

1

~

 2

4

First target released. RED light blinks. Second target released

automatically after the number of seconds indicated under the ~

symbol (i.e., 4 seconds)

1. From the Preferences Menu (see above), select the menu number that will be used. Save it

and return to the Setup Options menu.

2. From the Setup Options Menu: Press the [2-B] key to access Target Menu Setup.
3. Press the Enter [

] key to start.

4. The number of queues (steps) in the currently selected menu number is displayed.
5. If needed, use the

[3-C] and

 [8-H] keys to select the number of queues that will be

used in the modified menu. Typically the number of queues corresponds to the shooting

level:

Level

Targets

Number of

queues

1

all singles

5

2

three singles and a pair

4

3

one single and two pairs

3

6. Press the Enter [

] key to continue.

7. You will see the first (top/left) cell in the table.

In the example we show a cell, corresponding with the table

in page 7, with a single trap 2.
7.1.

The left side of the display shows the cell coordinates:

S:1 for stand #1 and Q:1 for queue #1

7.2.

The top line of the display shows T1 for 1

st

 trap, T2 for 2

nd

 trap,

RM for Pair Release Mode and FD for Following-Pair Delay.

The second line shows the values for the items in the first line.

8. To Modify the Trap:

8.1.

Press Enter [

] key to enter into a cell.

The title “T1” for the first trap will be highlighted.

8.2.

Use the

 [8-H] key to change the trap number to #1.

The cell coordinates will become highlighted indicating

a change has been made to the menu.

8.3.

Save the changes: the Enter [

] key to save changes and

exit the cell.

S:1    T1  T2  RM  FD
Q:1    2                    0

S:1

T1

  T2  RM  FD

Q:1    2                    0

S:1

T1

  T2  RM  FD

Q:1

    1                    0

Содержание MTX-8

Страница 1: ...4 Preferences Setup Items table 5 Detailed Review of Preferences Items 6 MTX 8 TARGET MENU SETUP 7 Target Menu Programming Overview 7 Modifying a Target Menu 8 RESETING TARGET MENUS TO FACTORY DEFAULT 9 APPENDIX 1 BUILT IN 5 STAND MENUS 10 APPENDIX 2 AUTOMATIC SEQUENCE 5 STAND FORMS 11 E EZ ZP Pu ul ll l M MT TX X 8 8 S Se et tu up p M Ma an nu ua al l ...

Страница 2: ...ull MTX 8 Setup Manual Page 2 Overview This manual is intended for gun club personnel responsible for setting up the EZPull MTX 8 multi target controller Target keys 1 8 White marking also for navigation selection Enter Fire key On Off Shift key ...

Страница 3: ...F or Exit Turn EZPull MTX 8 On To start using MTX 8 remove the protective rubber boot and open the battery door Follow the battery polarity marking on the bottom of the compartment install 2 AA batteries in the battery compartment and replace the battery door and rubber boot The LCD will display the version number for 3 seconds and then the MTX 8 will turn off To turn MTX 8 On Press the ON OFF SHI...

Страница 4: ...up items The setup item it shown on the top area of the display Use the 3 C and 8 H keys to modify the selected setup item s value The setup value is shown in large digits on the right side of the display Also shown are arrows indicating available navigation keys Up Down Left or Right Use the Enter key to save each modified value individually Use the key to exit and return to the Setup Options Men...

Страница 5: ...u number that will be used for Automatic Sequencing 01 06 CHAR 0 show traps as number 1 8 1 show traps as characters A H 00 01 IDLTIME Idle time to OFF in minutes 03 15 FPDLAY Default Following Pair delay in seconds 01 06 BACKLIT 0 LCD backlight OFF 01 15 backlight ON duration in seconds from pressing any key 00 15 RESERV1 Reserved not accessible 00 RESERV2 Reserved not accessible 00 PW 1 1st digi...

Страница 6: ...dle time no key presses will pass before the MTX 8 will automatically turn OFF Once OFF you will need to press the ON OFF key to resume operations from where you left the unit FPDLAY Default Following Pair delay in seconds When you program an automatic target sequence you have an option to select a Following Pair in which the second target will be delayed by anywhere from 1 to 6 seconds The FPDLAY...

Страница 7: ...ooting stand and up to 5 rows one for each shooting queue steps The table below illustrates a 5 Stand menu with 3 singles and one report pair on each station 4 Stand S 5 1 2 3 4 5 1 2 1 5 4 6 2 1 4 6 3 2 3 6 3 4 5 1 4 4 5 2 6 1 3 2 4 3 5 3 Queue Q 8 5 Since we work with a very small display we can only see one cell of the table on the screen We use the navigation keys to shuttle from cell to cell ...

Страница 8: ...mber of queues steps in the currently selected menu number is displayed 5 If needed use the 3 C and 8 H keys to select the number of queues that will be used in the modified menu Typically the number of queues corresponds to the shooting level Level Targets Number of queues 1 all singles 5 2 three singles and a pair 4 3 one single and two pairs 3 6 Press the Enter key to continue 7 You will see th...

Страница 9: ...nge T2 to 8 9 7 Use 5 E key to navigate to RM 9 8 Use and the 3 C to change RM from to 9 9 Save the changes the Enter key to save changes and exit the cell Reseting Target Menus to Factory Default Use this option carefully Resetting Target menus to the built in factory default will over write any custom designed Target Menu programmed into the MTX 8 1 From the Setup Options Menu Press the 6 F key ...

Страница 10: ... 4 6 3 2 3 6 3 4 5 1 Queue 4 4 5 2 6 1 3 2 4 3 5 Menu Number 3 Stand 6 Trap LEVEL 3 1 2 3 4 5 1 2 6 4 3 1 2 1 5 3 4 2 5 5 6 2 6 Queue 3 4 6 1 2 3 6 1 4 3 5 Menu Number 4 Stand 8 Trap LEVEL 1 1 2 3 4 5 1 5 6 2 1 3 2 3 4 7 5 2 3 1 2 8 6 7 4 6 3 1 4 8 Queue 5 8 5 4 7 1 Menu Number 5 Stand 8 Trap LEVEL 2 1 2 3 4 5 1 3 4 2 3 7 2 6 8 1 4 5 3 1 5 7 6 3 Queue 4 2 7 3 6 4 8 1 5 2 8 Menu Number 6 Stand 8 Tr...