Страница 2: ...m Electric Supply Safety Devices Suitable Inlet Water Pressure Water Connection Gas Connection Exhaust System 42 500 1 6GPM 11 WC Natural Draft Flue Water Controlled Electric Ignition 2 X D Cell Battery Flame Out Over Temperature 20 Minute Timer 8 100 PSI 1 2 NPT 1 2 NPT 3 8 Flare w Included Fitting EZ TANKLESS 101 OPERATION INSTALLATION MANUAL PAGE 01 ...

Страница 3: ... Setup and Operation 4 1 Control Dial Information 5 0 Recommended Maintenance Procedures 6 0 Troubleshooting 7 0 Contact Us Note Please ensure that the contents of this manual have been fully understood prior to installation or operation of this gas tankless water heater TABLE OF CONTENTS EZ TANKLESS 101 OPERATION INSTALLATION MANUAL PAGE 02 ...

Страница 4: ...epair center in Earl Park IN WHAT WILL EZ TANKLESS PROVIDE EZ Tankless will repair or replace the product or any part or component that is considered defective in materials or workmanship except as set forth below EZ Tankless will provide parts with free shipping for most repairs EZ Tankless will perform labor and pay shipping costs to repair the product if deemed necessary by EZ Tankless All repa...

Страница 5: ...2 0 WHAT S INCLUDED 1 x EZ Tankless Water Heater 1 x Showerhead 2 x 1 2 Bushings EZ TANKLESS 101 OPERATION INSTALLATION MANUAL PAGE 04 ...

Страница 6: ... pressure protection 20 Minute safety timer reduces the risk of carbon monoxide poisoning in the event of inadequate ventilation Independent control of water flow burners and gas flow allow for more flexible range in water temperature If water supply is interrupted the gas valve will automatically turn off High thermal efficiency and superb combustion performance Low water pressure ignition The he...

Страница 7: ...irst degree burns with exposure for as little as 3 Seconds at 140 f 20 Seconds at 130 f 8 Minutes at 120 f 03 Test the temperature of the water with your elbow to ensure adequate temperature before placing a child in the bath or shower 04 Do not leave children or an infirm person in the bath unsupervised 3 2 SCALDS FIRST AID GUIDANCE 01 Remove clothing remove all wet clothing quickly as wet clothi...

Страница 8: ...ese adjustments should be made with the unit running and heating water a To increase water flow slowly turn water temperature dial counter clockwise If while increasing water flow the EZ 101 flames out slowly return dial clockwise until unit reignites Stop At point of reignition you have reached the maximum flow rate as provided by your chosen water inlet source b To increase water temperature slo...

Страница 9: ...e This is why it is always recommended to set the water temperature dial to high during initial setup first ignition 2 SEASONAL MODE DIAL The seasonal mode dial will provide the largest flucuation in delivered water temperature This dial regulates the internal burners within the system Selecting between 1 2 or 3 burners the available options include summer spring autumn and winter respectively ran...

Страница 10: ... small debris from entering the heat exchanger Be sure to regularly check this screen for any debris that it may have caught Remove the screen from the inlet using a small pick or screwdriver blow away or rinse away any debris that may have accumulated and reinstall the filter screen into the water inlet before next use 4 FLUSH UNIT ONCE A YEAR With the heating of water through a heat exchanger co...

Страница 11: ...using white connectors 8 Detach the white connectors from each other thus separating the computer board and micro switch 9 Using a flat blade screwdriver complete the circuit between the two prongs located inside the white connector on the computer board side of the red and blue wires 10 If a spark is produced when doing so the unit micro switch has failed If no spark is produced the unit computer...

Страница 12: ...rip the igniter by running water through the system or lift the pressure plate off of the microswitch With you finger resting on the solenoid and the igniter engaged electricity should flow through the solenoid and pull the valve into the solenoid If this does not happen a new gas solenoidis required 3 If the igniter sparks the unit flames up but extinguishes itself in 5 10 seconds a faulty limit ...